Vercnocke, Andrew J.

https://orcid.org/0000-0003-0823-8104

Mayo Clinic

Mayo Clinic

Citations 13

Pressure chamber and micro-CT analysis of twinkling materials to evaluate features important to color Doppler twinkling
Wood, Benjamin, Vercnocke, Andrew, Marsh, Jeff, Lee, Christine, Vercnocke, Andrew J. , Marsh, Jeffrey F., Urban, Matthew W.

The Journal of the Acoustical Society of America | May 12, 2026 | Volume: 158 | Issue: 4_Supplement | Pages: A426-A426

10.1121/10.0041383 Get It

Color Doppler twinkling is associated with rough-surfaced objects like kidney stones, some clinical breast biopsy markers, and polymethyl methacrylate (PMMA) bone cement. Microbubbles are theorized as the predominant source of twinkling, supported by decreased twinkling under increased pressure. PMMA, metallic breast markers, a low-twinkling PMMA sample, and a non-twinkling metal rod were scanned in a pressure chamber up to 1000 psi using a General Electric Logiq E9 system and C1-6 probe (1.7–3.6 MHz Doppler transmit frequency). Clinical markers maintained distinct twinkling up to 250 psi. PMMA often twinkled at higher pressures, sometimes up to 1000 psi. The controls showed no twinkling. To understand physical structure associations with twinkling, the samples were scanned in a micro-CT system with a pixel resolution of 2 μm. Analysis of PMMA and Cork internal voids showed no correlation with twinkling. However, a correlation between Sa (average difference between the mean surface profile and actual surface profile) values and twinkling was found. This indicates that internal structure is not important for twinkling, and certain surface roughness is critical, possibly providing sites for surface microbubbles to oscillate from incident ultrasound waves.
Automated Instance Cyst Segmentation of Polycystic Kidneys in MRIs
Gregory, Adriana , Anaam, Deema , Vercnocke, Andrew J. , Edwards, Marie E., Kline, Timothy L. , Chebib, Fouad T. , Torres, Vicente E. , Harris, Peter C. , Erickson, Bradley J.

Journal of the American Society of Nephrology | May 17, 2024 | Volume: 31 | Issue: 10S | Pages: 499-499

10.1681/asn.20203110s1499a Get It

Measurement of enhanced vasa vasorum density in a porcine carotid model using photon counting detector CT
Marsh, Jeffrey F., Vercnocke, Andrew J. , Tao, Shengzhen , Anderson, Jill , Ritman, Erik L., Rajendran, Kishore , Anderson, Jill L, Leng, Shuai , McCollough, Cynthia H , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | February 6, 2023 | Volume: 10 | Issue: 01 | Pages: No page available

10.1117/1.jmi.10.1.016001 Get It

Benchtop proof of concept and comparison of iron- and magnesium-based bioresorbable flow diverters
Bilgin, Cem , Vercnocke, Andrew J. , Carlson, Kent, Kadirvel, Ramanathan , Griebel, Adam J. , Schaffer, Jeremy E. , Dragomir‐Daescu, Dan , Kallmes, David F. , Oliver, Alexander A , Dragomir-Daescu, Dan, Guillory, Roger J.

Journal of Neurosurgery | December 23, 2022 | Volume: 139 | Issue: 1 | Pages: 150-156

10.3171/2022.11.jns222213 Get It

OBJECTIVE Bioresorbable flow diverters (BRFDs) could significantly improve the performance of next-generation flow diverter technology. In the current work, magnesium and iron alloy BRFDs were prototyped and compared in terms of porosity/pore density, radial strength, flow diversion functionality, and resorption kinetics to offer insights into selecting the best available bioresorbable metal candidate for the BRFD application. METHODS BRFDs were constructed with braided wires made from alloys of magnesium (MgBRFD) or iron (FeBRFD). Pore density and crush resistance force were measured using established methods. BRFDs were deployed in silicone aneurysm models attached to flow loops to investigate flow diversion functionality and resorption kinetics in a simulated physiological environment. RESULTS The FeBRFD exhibited higher pore density (9.9 vs 4.3 pores/mm2) and crush resistance force (0.69 ± 0.05 vs 0.53 ± 0.05 N/cm, p = 0.0765, n = 3 per group) than the MgBRFD, although both crush resistances were within the range previously reported for FDA-approved flow diverters. The FeBRFD demonstrated greater flow diversion functionality than the MgBRFD, with significantly higher values of established flow diversion metrics (mean transit time 159.6 ± 11.9 vs 110.9 ± 1.6, p = 0.015; inverse washout slope 192.5 ± 9.0 vs 116.5 ± 1.5, p = 0.001; n = 3 per group; both metrics expressed as a percentage of the control condition). Last, the FeBRFD was able to maintain its braided structure for > 12 weeks, whereas the MgBRFD was almost completely resorbed after 5 weeks. CONCLUSIONS The results of this study demonstrated the ability to manufacture BRFDs with magnesium and iron alloys. The data suggest that the iron alloy is the superior material candidate for the BRFD application due to its higher mechanical strength and lower resorption rate relative to the magnesium alloy.
Magnetic resonance radiomic feature performance in pulmonary nodule classification and impact of segmentation variability on radiomics
Koo, Chi Wan , Kline, Timothy L. , Yoon, Joo Hee , Vercnocke, Andrew J. , Johnson, Mathew P, Suman, Garima , Lu, Aiming , Larson, Nicholas B. , Larson, Nicholas B

The British Journal of Radiology | November 11, 2022 | Volume: 95 | Issue: 1140 | Pages: No page available

10.1259/bjr.20220230 Get It

Objective: Investigate the performance of multiparametric MRI radiomic features, alone or combined with current standard-of-care methods, for pulmonary nodule classification. Assess the impact of segmentation variability on feature reproducibility and reliability. Methods: Radiomic features were extracted from 74 pulmonary nodules of 68 patients who underwent nodule resection or biopsy after MRI exam. The MRI features were compared with histopathology and conventional quantitative imaging values (maximum standardized uptake value [SUVmax] and mean Hounsfield unit [HU]) to determine whether MRI radiomic features can differentiate types of nodules and associate with SUVmax and HU using Wilcoxon rank sum test and linear regression. Diagnostic performance of features and four machine learning (ML) models were evaluated with area under the receiver operating characteristic curve (AUC) and 95% confidence intervals (CIs). Concordance correlation coefficient (CCC) assessed the segmentation variation impact on feature reproducibility and reliability. Results: Elevn diffusion-weighted features distinguished malignant from benign nodules (adjusted p < 0.05, AUC: 0.73–0.81). No features differentiated cancer types. Sixty-seven multiparametric features associated with mean CT HU and 14 correlated with SUVmax. All significant MRI features outperformed traditional imaging parameters (SUVmax, mean HU, apparent diffusion coefficient [ADC], T1, T2, dynamic contrast-enhanced imaging values) in distinguishing malignant from benign nodules with some achieving statistical significance (p < 0.05). Adding ADC and smoking history improved feature performance. Machine learning models demonstrated strong performance in nodule classification, with extreme gradient boosting (XGBoost) having the highest discrimination (AUC = 0.83, CI=[0.727, 0.932]). We found good to excellent inter- and intrareader feature reproducibility and reliability (CCC≥0.80). Conclusion: Eleven MRI radiomic features differentiated malignant from benign lung nodules, outperforming traditional quantitative methods. MRI radiomic ML models demonstrated good nodule classification performances with XGBoost superior to three others. There was good to excellent inter- and intrareader feature reproducibility and reliability. Advances in knowledge: Our study identified MRI radiomic features that successfully differentiated malignant from benign lung nodules and demonstrated high performance of our MR radiomic feature-based ML models for nodule classification. These new findings could help further establish thoracic MRI as a non-invasive and radiation-free alternative to standard practice for pulmonary nodule assessment.
In Vivo Prediction of Kidney Stone Fragility Using Radiomics-Based Regression Models
Pillai, Parvathy Sudhir , Hsieh, Scott S. , Vercnocke, Andrew J. , Potretzke, Aaron M. , Koo, Kevin , Ferrero, Andrea , Sudhir Pillai, Parvathy, McCollough, Cynthia H.

Journal of Endourology | October 7, 2022 | Volume: 37 | Issue: 4 | Pages: 443-452

10.1089/end.2022.0483 Get It

Introduction: The surgical technique for urinary stone removal is partly influenced by its fragility, as prognosticated by the clinician. This feasibility study aims to develop a linear regression model from CT-based radiomic markers to predict kidney stone comminution time in vivo with two ultrasonic lithotrites. Materials and Methods: Patients identified by urologists at our institution as eligible candidates for percutaneous nephrolithotomy were prospectively enrolled. The active engagement time of the lithotrite in breaking the stone during surgery denoted the comminution time of each stone. The comminution rate was computed as the stone volume disintegrated per minute. Stones were grouped into three fragility classes (fragile, moderate, hard), based on inverse of the comminution rates with respect to the mean. Multivariable linear regression models were trained with radiomic features extracted from clinical CT images to predict comminution times in vivo . The model with the least root mean squared error (RMSE) on comminution times and the fewest misclassification of fragility was finally selected. Results: Twenty-eight patients with 31 stones in total were included in this study. Stones in the cohort averaged 1557 (±2472) mm 3 in volume and 5.3 (±7.4) minutes in comminution time. Ten stones had nonmoderate fragility. Linear regression of stone volume alone predicted comminution time with an RMSE of 6.8 minutes and missed all 10 stones with nonmoderate fragility. A fragility model that included stone volume, internal morphology, shape-based radiomics, and device type improved RMSE to below 3.3 minutes and correctly classified 20/21 moderate and 6/10 nonmoderate stones. Conclusions: CT metrics-based fragility models may provide information to surgeons regarding kidney stone fragility and facilitate the selection of stone removal procedures.
Preconditioning with Foam-mediated External Suction on Flap Microvasculature and Perfusion in a Rodent Model
Mohan, Anita T. , Zhu, Lin , Michalak, Gregory J. , Laungani, Alexis, Vercnocke, Andrew J. , Moran, Steven L. , Saint‐Cyr, Michel, Laungani, Alexis T

Plastic and Reconstructive Surgery - Global Open | January 13, 2021 | Volume: 8 | Issue: 8 | Pages: e2739

10.1097/gox.0000000000002739 Get It

Background: Foam-mediated external suction (FMES) has previously shown to improve tissue microcirculation. We hypothesized that preconditioning fasciocutaneous perforator flaps with FMES would augment perfusion and demonstrate greater capillary recruitment. Methods: Gluteal perforator flaps were designed on sixteen 400 g rats. Continuous FMES at −125 mm Hg was applied on one side (intervention) to precondition tissue for 5 days, with the contralateral side as a paired control. In group A, we assessed changes following pretreatment, after surgery, and 7 days postprocedure, and in group B, we evaluated changes during preconditioning alone. In group A (N = 8), control and intervention flaps were assessed using laser-assisted indocyanine green fluorescence angiography. In group B, flap regions were assessed using 4-dimensional computed tomographic angiography. All flaps were analyzed for microvessel density using micro–computed tomography and histological assessment using hematoxylin and eosin and CD3 immunohistochemistry. Results: Thirty-two flaps were included in this study (N = 16 intervention and matched controls). Four-dimensional computed tomographic angiography demonstrated 17% greater tissue perfusion in preconditioned flaps (mean, 78.7 HU; SD, 8.8) versus controls (mean, 67.3 HU; SD, 15.7; P < 0.01). Laser-assisted indocyanine green fluorescence angiography showed a 30% higher mean absolute intensity in preconditioned flaps versus controls (P < 0.01). Postsurgery mean absolute intensity in preconditioned flaps remained 21% higher than in controls (P = 0.03). Preconditioned flaps demonstrated a 2-fold increase in mean vessel volume of 9.1 mm3 (SD, 7) versus 4.5 mm3 (SD, 3) in controls (P = 0.04); there was a 33% higher mean area fraction of CD31 in preconditioned flaps, 3.9% (SD, 3) versus 2.9% (SD, 3) in controls (P = 0.03). Conclusion: FMES preconditioning has the potential to augment vascularity of tissue for flap harvest; however, further experimental studies are required to optimize strategies and evaluate long-term effects for clinical applications.
Evaluation of a photon counting Medipix3RX cadmium zinc telluride spectral x-ray detector
Marsh, Jeffrey F., Jorgensen, Steven M., Rundle, David S., Vercnocke, Andrew J. , Butler, Philip H. , Ritman, Erik L., Leng, Shuai , Butler, Philip H , McCollough, Cynthia H , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | December 4, 2018 | Volume: 5 | Issue: 04 | Pages: 1

10.1117/1.jmi.5.4.043503 Get It

Arterial wall perfusion measured with photon counting spectral x-ray CT
Jorgensen, Steven M., Korinek, Mark J., Vercnocke, Andrew J. , Anderson, Jill , Halaweish, Ahmed F., Ritman, Erik L., Anderson, Jill L, Korinek, Mark, Leng, Shuai , McCollough, Cynthia H.

SPIE Proceedings | October 4, 2016 | Volume: 9967 | Issue: No issue available | Pages: 99670B

10.1117/12.2238817 Get It

Evaluation of a photon counting Medipix3RX CZT spectral x-ray detector
Jorgensen, Steven M., Vercnocke, Andrew J. , Rundle, David S., Butler, Philip H. , Ritman, Erik L., McCollough, Cynthia H.

SPIE Proceedings | October 3, 2016 | Volume: 9969 | Issue: No issue available | Pages: 99690J

10.1117/12.2236501 Get It