Back to Authors

Carlson, Kent

Mayo Clinic

Mayo Clinic

Citations 5

Machine Learning Prediction of Left Ventricular Assist Device Thrombosis from Acoustic Harmonic Power
Carlson, Kent, Dragomir‐Daescu, Dan , Boilson, Barry A. , Carlson, Kent D, Razonable, Raymund R

Bioengineering | May 2, 2025 | Volume: 12 | Issue: 5 | Pages: 484

10.3390/bioengineering12050484 Get It

Left ventricular assist device (LVAD) thrombosis typically presents late and may have devastating consequences for patients. While LVAD pump thrombosis is uncommon with current pump designs, many patients worldwide remain supported with previous generations of LVADs, including the HeartWare device (HVAD). Researchers have focused on investigating the acoustic signatures of LVADs to enable earlier detection and treatment of this condition. This study explored the use of machine learning algorithms to predict thrombosis from harmonic power values determined from the acoustic signatures of a cohort of HVAD patients (n = 11). The current dataset was too small to develop a predictive model for new data, but exhaustive cross validation indicated that machine learning models using the first two or the first three harmonic power values both resulted in reasonable prediction accuracy of the thrombosis outcome. Furthermore, when principal component analysis (PCA) was applied to the harmonic power variables from these promising models, the use of the resulting PCA variables in machine learning models further increased the thrombosis outcome prediction accuracy. K-nearest neighbor (KNN) models gave the best predictive accuracy for this dataset. Future work with a larger HVAD recording dataset is necessary to develop a truly predictive model of HVAD thrombosis. Such a predictive model would provide clinicians with a marker to detect HVAD thrombosis based directly on pump performance, to be used along with current clinical markers.
Benchtop proof of concept and comparison of iron- and magnesium-based bioresorbable flow diverters
Bilgin, Cem , Vercnocke, Andrew J. , Carlson, Kent, Kadirvel, Ramanathan , Griebel, Adam J. , Schaffer, Jeremy E. , Dragomir‐Daescu, Dan , Kallmes, David F. , Oliver, Alexander A , Dragomir-Daescu, Dan, Guillory, Roger J.

Journal of Neurosurgery | December 23, 2022 | Volume: 139 | Issue: 1 | Pages: 150-156

10.3171/2022.11.jns222213 Get It

OBJECTIVE Bioresorbable flow diverters (BRFDs) could significantly improve the performance of next-generation flow diverter technology. In the current work, magnesium and iron alloy BRFDs were prototyped and compared in terms of porosity/pore density, radial strength, flow diversion functionality, and resorption kinetics to offer insights into selecting the best available bioresorbable metal candidate for the BRFD application. METHODS BRFDs were constructed with braided wires made from alloys of magnesium (MgBRFD) or iron (FeBRFD). Pore density and crush resistance force were measured using established methods. BRFDs were deployed in silicone aneurysm models attached to flow loops to investigate flow diversion functionality and resorption kinetics in a simulated physiological environment. RESULTS The FeBRFD exhibited higher pore density (9.9 vs 4.3 pores/mm2) and crush resistance force (0.69 ± 0.05 vs 0.53 ± 0.05 N/cm, p = 0.0765, n = 3 per group) than the MgBRFD, although both crush resistances were within the range previously reported for FDA-approved flow diverters. The FeBRFD demonstrated greater flow diversion functionality than the MgBRFD, with significantly higher values of established flow diversion metrics (mean transit time 159.6 ± 11.9 vs 110.9 ± 1.6, p = 0.015; inverse washout slope 192.5 ± 9.0 vs 116.5 ± 1.5, p = 0.001; n = 3 per group; both metrics expressed as a percentage of the control condition). Last, the FeBRFD was able to maintain its braided structure for > 12 weeks, whereas the MgBRFD was almost completely resorbed after 5 weeks. CONCLUSIONS The results of this study demonstrated the ability to manufacture BRFDs with magnesium and iron alloys. The data suggest that the iron alloy is the superior material candidate for the BRFD application due to its higher mechanical strength and lower resorption rate relative to the magnesium alloy.
Bioresorbable flow diverters for the treatment of intracranial aneurysms: review of current literature and future directions
Oliver, Alexander A , Carlson, Kent, Bilgin, Cem , Larco, Jorge Arturo , Kadirvel, Ramanathan , Daescu, Dan Dragomir, Kallmes, David F. , Carlson, Kent D, Arturo Larco, Jorge L , Dragomir Daescu, Dan, Oliver, Alexander A , Guillory, Roger J.

Journal of NeuroInterventional Surgery | May 30, 2022 | Volume: 15 | Issue: 2 | Pages: 178-182

10.1136/neurintsurg-2022-018941 Get It

The use of flow diverters is a rapidly growing endovascular approach for the treatment of intracranial aneurysms. All FDA-approved flow diverters are composed of nitinol or cobalt-chromium, which will remain in the patient for the duration of their life. Bioresorbable flow diverters have been proposed by several independent investigators as the next generation of flow diverting devices. These devices aim to serve their transient function of occluding and healing the aneurysm prior to being safely resorbed by the body, eliminating complications associated with the permanent presence of conventional flow diverters. Theoretical advantages of bioresorbable flow diverters include (1) reduction in device-induced thrombosis; (2) reduction in chronic inflammation and device-induced stenosis; (3) reduction in side branch occlusion; (4) restoration of physiological vasomotor function; (5) reduction in imaging artifacts; and (6) use in pediatric applications. Advances made in the similar bioresorbable coronary stenting field highlight some of these advantages and demonstrate the feasibility and safety of bioresorbable endovascular devices in the clinic. The current work aims to review the progress of bioresorbable flow diverters, identify opportunities for further investigation, and ultimately stimulate the advancement of this technology.
Morphological and Hemodynamic Changes during Cerebral Aneurysm Growth
Nordahl, Emily Rose, Dennis, Kendall D. , Sejkorová, Alena , Hejčl, Aleš , Hron, J. , Švihlová, Helena , Carlson, Kent, Suzen, Yildirim , Dragomir‐Daescu, Dan , Uthamaraj, Susheil , Sejkorová, Alena , Hejčl, Aleš , Hron, Jaroslav , Švihlová, Helena , Carlson, Kent D, Dragomir-Daescu, Dan

Brain Sciences | April 19, 2021 | Volume: 11 | Issue: 4 | Pages: 520

10.3390/brainsci11040520 Get It

Computational fluid dynamics (CFD) has grown as a tool to help understand the hemodynamic properties related to the rupture of cerebral aneurysms. Few of these studies deal specifically with aneurysm growth and most only use a single time instance within the aneurysm growth history. The present retrospective study investigated four patient-specific aneurysms, once at initial diagnosis and then at follow-up, to analyze hemodynamic and morphological changes. Aneurysm geometries were segmented via the medical image processing software Mimics. The geometries were meshed and a computational fluid dynamics (CFD) analysis was performed using ANSYS. Results showed that major geometry bulk growth occurred in areas of low wall shear stress (WSS). Wall shape remodeling near neck impingement regions occurred in areas with large gradients of WSS and oscillatory shear index. This study found that growth occurred in areas where low WSS was accompanied by high velocity gradients between the aneurysm wall and large swirling flow structures. A new finding was that all cases showed an increase in kinetic energy from the first time point to the second, and this change in kinetic energy seems correlated to the change in aneurysm volume.
Finite Element Analysis of the Septal Cartilage L-Strut
Menapace, Deanna C., Carlson, Kent, Dragomir‐Daescu, Dan , Matsumoto, Jane M., Carlson, Kent D, Matsumoto, Jane, Hamilton, Grant

Facial Plastic Surgery & Aesthetic Medicine | July 28, 2020 | Volume: 23 | Issue: 2 | Pages: 90-97

10.1089/fpsam.2019.0012 Get It

Importance: Septoplasty is one of the most commonly performed operations in the head and neck. However, the reasons for septoplasty failure and the additional stress of performing a chondrotomy on the septal cartilage are not well understood. Design, Setting, and Participants: A finite element model of the nasal septum was created using a microcomputed tomography scan of the nasoseptal complex that was reconstructed into a three-dimensional model in silico. Testing included four common chondrotomy designs: traditional L-strut, double-cornered chondrotomy (DCC), curved L-strut, and the C-curve. Tip displacement was applied in a vector parallel to the caudal strut to simulate nasal tip palpation. Main Outcomes and Measures: With finite element analysis, the maximum principal stress (MPS), von Mises stress (VMS), harvested cartilage volume, and surface area were recorded. Results: The highest MPS for the L-strut, DCC, curved L-strut, and C-curve was identified at the corner of the chondrotomy. The MPS at the corner of the chondrotomy was reduced 44% when comparing the C-curve with the traditional L-strut. The VMS patterns showed compressive stress along the caudal septum in all models, but at the corner, the stresses were highest in the chondrotomies designed with sharp-angled corners. The VMS showed a 76% decrease when comparing the C-curve with the traditional L-strut. The stress across the anterior septal angle is also higher in models with sharp-angled corners. Cartilage harvest volumetric and surface area assessments did not show meaningful differences between shapes. Conclusions and Relevance: The highest area of stress is near the transition of the dorsal to caudal septum in all models. Stresses are relatively higher in chondrotomy shapes that contain sharp-angled corners. The relative reduction in MPS and VMS utilizing a C-curve instead of an L-strut may decrease the likelihood that the septum will deform or fail in this region. The volume and surface area of the C-curve are similar to that of the L-strut technique. Avoiding sharp-angled corners reduces the stresses at the corner of the chondrotomy and across the anterior septal angle. Using a C-curve may be an improved septoplasty design.