Back to Authors

Arturo Larco, Jorge L

0000-0002-8259-2681

Mayo Clinic

Department of Radiology, Mayo Clinic, Jacksonville, FL, USA.

Citations 8

Transvenous embolization of cerebrospinal fluid-venous fistulas: Independent validation and feasibility of upper-extremity approach and using dual-microcatheter and balloon pressure cooker technique
Parizadeh, Donna , Fermo, Olga , Larco, Jorge Arturo , Quiñones‐Hinojosa, Alfredo , Clendenen, Steven R. , Rozen, Todd D. , Vibhute, Prasanna , Arturo Larco, Jorge L , Erben, Young M, Clendenen, Steven, Huynh, Thien J, Parizadeh, Donna , Gupta, Vivek , Grewal, Sanjeet S. , Erben, Young , Huynh, Thien

Journal of NeuroInterventional Surgery | January 23, 2023 | Volume: 15 | Issue: 12 | Pages: 1234-1241

10.1136/jnis-2022-019946 Get It

Background Transvenous embolization is emerging as a promising treatment for cerebrospinal fluid-venous fistulas (CVF) associated with spontaneous intracranial hypotension (SIH). Objective To perform an independent validation of the efficacy and safety of the procedure and describe the procedural techniques used at our institution. Methods A retrospective review was performed including consecutive patients with SIH who had undergone CVF embolization with 3-month clinical and imaging follow-up. Clinical evaluation included the Patient Global Impression of Change (PGIC) Scale and six-item Headache Impact Test (HIT-6). Bern SIH score was used for imaging evaluation on brain MRI. Post-treatment changes in scores were assessed by Wilcoxon signed rank test. Procedural technical details, including use of upper-extremity access and dual-microcatheter pressure cooker technique, were recorded. Results 18 patients (13 female, median age 60 years) were included. 17 (94%) procedures were performed with upper-extremity access and 12 (67%) using dual-microcatheter pressure cooker technique. After embolization, 16 (89%) patients reported much or very much improved at follow-up PGIC; median (IQR) HIT-6 score improved from 68 (62–72) to 36 (36–38) and Bern SIH score improved from 8 (6–8) to 3 (1.5–3.5), p values <0.001. Side effects were transient embolization site back pain in 15 (83%) and rebound intracranial hypertension requiring medical management in 9 (50%) patients. HIT-6 and Bern SIH score changes were similar between conventional and pressure cooker techniques ( p values >0.05). Conclusion Transvenous embolization is independently validated as a highly effective and safe treatment for CVF and is feasible using upper-extremity venous access. Dual-microcatheter and balloon/coil pressure cooker techniques may be used to optimize distribution of embolic material and potentially, treatment efficacy.
Bioresorbable flow diverters for the treatment of intracranial aneurysms: review of current literature and future directions
Oliver, Alexander A , Carlson, Kent, Bilgin, Cem , Larco, Jorge Arturo , Kadirvel, Ramanathan , Daescu, Dan Dragomir, Kallmes, David F. , Carlson, Kent D, Arturo Larco, Jorge L , Dragomir Daescu, Dan, Oliver, Alexander A , Guillory, Roger J.

Journal of NeuroInterventional Surgery | May 30, 2022 | Volume: 15 | Issue: 2 | Pages: 178-182

10.1136/neurintsurg-2022-018941 Get It

The use of flow diverters is a rapidly growing endovascular approach for the treatment of intracranial aneurysms. All FDA-approved flow diverters are composed of nitinol or cobalt-chromium, which will remain in the patient for the duration of their life. Bioresorbable flow diverters have been proposed by several independent investigators as the next generation of flow diverting devices. These devices aim to serve their transient function of occluding and healing the aneurysm prior to being safely resorbed by the body, eliminating complications associated with the permanent presence of conventional flow diverters. Theoretical advantages of bioresorbable flow diverters include (1) reduction in device-induced thrombosis; (2) reduction in chronic inflammation and device-induced stenosis; (3) reduction in side branch occlusion; (4) restoration of physiological vasomotor function; (5) reduction in imaging artifacts; and (6) use in pediatric applications. Advances made in the similar bioresorbable coronary stenting field highlight some of these advantages and demonstrate the feasibility and safety of bioresorbable endovascular devices in the clinic. The current work aims to review the progress of bioresorbable flow diverters, identify opportunities for further investigation, and ultimately stimulate the advancement of this technology.
Intra-procedural cerebral sinus thrombosis during endovascular treatment of idiopathic intracranial hypertension
Larco, Jorge Arturo , Abbasi, Mehdi , Kadirvel, Ramanathan , Kallmes, David F. , Brinjikji, Waleed , Arturo Larco, Jorge L , Savastano, Luis

The Neuroradiology Journal | April 30, 2022 | Volume: 35 | Issue: 5 | Pages: 654-657

10.1177/19714009221096837 Get It

Stenting of the intracranial venous sinuses has shown promising results in patients who are refractory to medical treatment of idiopathic intracranial hypertension (IIH). Among the reported complications associated with this procedure, in-stent thrombosis is an unreported one. We present a case of cerebral sinus thrombosis during endovascular treatment of IIH. A 33-year-old man with multiple comorbidities was presented with non-specific vision changes and headaches. Initial workup revealed a diagnosis of idiopathic intracranial hypertension which was treated medically but with no improvement. Therefore, cerebral sinus stenting was pursued. During the procedure, an in-stent thrombus was identified which was retrieved mechanically and was sent for histological and immunohistochemical evaluation. The retrieved thrombus was predominantly composed of RBCs (57.8%) followed by fibrin (30.78%), platelet (6.4%), and WBCs (5.95%), with high expression of CitH3 (neutrophil extra cellular traps specific marker) (10.9%), and CD66 (11.35%).
Correlation of Neutrophil to Lymphocyte Ratio with Expression of Neutrophil Extracellular Traps Within Stroke Emboli
Larco, Jorge Arturo , Abbasi, Mehdi , Mereuta, Madalina Oana, Liu, Yang , Dai, Daying , Kadirvel, Ramanathan , Kallmes, David F. , Brinjikji, Waleed , Madhani, Sarosh Irfan , Liu, Yang , Dai, Daying , Kadirvel, Ram , Savastano, Luis , Kallmes, David F , Brinjikji, Waleed , Arturo Larco, Jorge L

Interventional Neuroradiology | December 8, 2021 | Volume: 28 | Issue: 6 | Pages: 726-730

10.1177/15910199211065530 Get It

Background & Purpose It has been hypothesized that circulating neutrophils have a direct correlation with the composition of emboli in acute ischemic stroke (AIS). The aim of this study is to evaluate the association between neutrophil-lymphocyte ratio (NLR) in peripheral blood and the expression of neutrophil extracellular traps (NETs) within stroke emboli. Methods Consecutive patients with acute ischemic stroke (AIS) due to large vessel occlusion (LVO) that underwent mechanical thrombectomy (MT) were included. Patients were divided into two groups based on NLR median value. Retrieved thrombi were histologically analyzed using Martius Scarlett Blue (MSB) for main thrombus components including red blood cells (RBCs), white blood cells (WBCs), fibrin and platelet. Immunohistochemistry staining for von Willebrand Factor (vWF) and anti-citrullinated H3 (H3Cit; NETs marker) was also performed. Results Samples from a total of 84 patients were included. The average percentage of RBCs, WBCs, fibrin, platelet, H3Cit, and vWF components in thrombi were 45.1%, 3.5%, 21.8%, 29.6%, 19.7% and 14.8% respectively. When stratifying by NLR group [low (≤3.94) versus high (>3.95)], high NLR group had significantly more WBCs (4.5%), fibrin (24.2%), H3Cit (22.7%) and vWF (17.1%) thrombus fractions compared to low NLR group. Additionally, RBC content (38.8%) was lower in the high NLR group. Conclusions NLR is correlated with the amounts of WBCs, fibrin, NETs and vWF within the thrombi retrieved from AIS patients due to LVO.
Per-pass analysis of recanalization and good neurological outcome in thrombectomy for stroke: Systematic review and meta-analysis
Larco, Jorge Arturo , Abbasi, Mehdi , Liu, Yang , Kadirvel, Ramanathan , Brinjikji, Waleed , Arturo Larco, Jorge L , Madhani, Sarosh Irfan , Shahid, Adnan Hussain , Kadirvel, Ram , Brinjikji, Waleed , Savastano, Luis E., Liu, Yang , Savastano, Luis

Interventional Neuroradiology | July 7, 2021 | Volume: 28 | Issue: 3 | Pages: 358-363

10.1177/15910199211028342 Get It

Background and aim First pass effect (FPE) is defined as achieving a complete recanalization with a single thrombectomy device pass. Although clinically desired, FPE is reached in less than 30% of thrombectomy procedures. Multiple device passes are often necessary to achieve successful or complete recanalization. We performed a systematic review and meta-analysis to determine the recanalization rate after each pass of mechanical thrombectomy and its association with good neurological outcome. Methods A literature search was performed for studies reporting the number of device passes required for either successful (mTICI 2b or higher) or complete (mTICI 2c or higher) recanalization. Using random-effect meta-analysis, we evaluated the likelihood of recanalization and good neurological outcome (measured with the modified Rankin Score <2 at 90 days) after each device pass. Results Thirteen studies comprising 4197 patients were included. Among cases with failed first pass, 24% of them achieved final complete recanalization and 45% of them achieved final successful recanalization. Independently to the total number of previously failed attempts, the likelihood of achieving successful recanalization was 30% per pass, and the likelihood to achieve complete recanalization was about 20% per pass. The likelihood of good neurological outcome in patients with final successful recanalization decreased after each device pass: 55% after the first pass, 48% after the second pass, 42% after the third pass, 36% after the fourth pass, and 26% for 5 passes or more. Conclusion Each pass is associated with a stable likelihood of recanalization but a decreased likelihood of good neurological outcome.
Failure modes and effects analysis of mechanical thrombectomy for stroke discovered in human brains
Liu, Yang, Gebrezgiabhier, Daniel, Reddy, Adithya S., Davis, Evan, Zheng, Yihao, Larco, Jorge L. Arturo, Shih, Albert J., Pandey, Aditya S., Savastano, Luis E., Gebrezgiabhier, Daniel , Larco, Jorge Arturo , Arturo Larco, Jorge L , Liu, Yang, Reddy, Adithya S., Davis, Evan, Zheng, Yihao, Shih, Albert J., Pandey, Aditya S., Savastano, Luis E.

Journal of Neurosurgery | June 4, 2021 | Volume: 136 | Issue: 1 | Pages: 197-204

10.3171/2020.11.jns203684 Get It

OBJECTIVE Despite advancement of thrombectomy technologies for large-vessel occlusion (LVO) stroke and increased user experience, complete recanalization rates linger around 50%, and one-third of patients who have undergone successful recanalization still experience poor neurological outcomes. To enhance the understanding of the biomechanics and failure modes, the authors conducted an experimental analysis of the interaction of emboli/artery/devices in the first human brain test platform for LVO stroke described to date. METHODS In 12 fresh human brains, 105 LVOs were recreated by embolizing engineered emboli analogs and recanalization was attempted using aspiration catheters and/or stent retrievers. The complex mechanical interaction between diverse emboli (elastic, stiff, and fragment prone), arteries (anterior and posterior circulation), and thrombectomy devices were observed, analyzed, and categorized. The authors systematically evaluated the recanalization process through failure modes and effects analysis, and they identified where and how thrombectomy devices fail and the impact of device failure. RESULTS The first-pass effect (34%), successful (71%), and complete (60%) recanalization rates in this model were consistent with those in the literature. Failure mode analysis of 184 passes with thrombectomy devices revealed the following. 1) Devices loaded the emboli with tensile forces leading to elongation and intravascular fragmentation. 2) In the presence of anterograde flow, small fragments embolize to the microcirculation and large fragments result in recurrent vessel occlusion. 3) Multiple passes are required due to recurrent (15%) and residual (73%) occlusions, or both (12%). 4) Residual emboli remained in small branching and perforating arteries in cases of alleged complete recanalization (28%). 5) Vacuum caused arterial collapse at physiological pressures (27%). 6) Device withdrawal caused arterial traction (41%), and severe traction provoked avulsion of perforating and small branching arteries. CONCLUSIONS Biomechanically superior thrombectomy technologies should prevent unrestrained tensional load on emboli, minimize intraluminal embolus fragmentation and release, improve device/embolus integration, recanalize small branching and perforating arteries, prevent arterial collapse, and minimize traction.
Histological evaluation of acute ischemic stroke thrombi may indicate the occurrence of vessel wall injury during mechanical thrombectomy
Mereuta, Oana Madalina , Abbasi, Mehdi , Fitzgerald, Seán , Dai, Daying , Kadirvel, Ram , Almekhlafi, Mohammed , Kvamme, Peter , Gounis, Matthew J. , Patel, Biraj M. , Aghaebrahim, Amin, Sauvageau, Eric , Bhuva, Parita, Soomro, Jazba , Thacker, Ike, Copelan, Alexander , Nazari, Pouya , Cantrell, Donald R. , Mohammaden, Mahmoud , Pisani, Leonardo , Puri, Ajit S , Meves, Alexander , Larco, Jorge Arturo , Cloft, Harry J. , Kallmes, David F. , Doyle, Karen , Brinjikji, Waleed , Almekhlafi, Mohammed A , Mendes Pereira, Vitor , Jahromi, Babak S , Gounis, Matthew J , Nazari, Pouya , Al-Bayati, Alhamza , Pisani, Leonardo , Rodrigues, Gabriel Martins , Arturo Larco, Jorge L , Savastano, Luis , Doyle, Karen M , Brinjikji, Waleed , Patel, Biraj M , Fitzgerald, Seán , Dai, Daying , Madalina Mereuta, Oana , Kadirvel, Ramanathan , Hanel, Ricardó A. , Yoo, Albert J. , Layton, Kennith F. , Almandoz, Josser E Delgado , Jahromi, Babak S. , Nogueira, Raul G. , Demchuk, Andrew M. , Kayan, Yasha , Haussen, Diogo C , Al‐Bayati, Alhamza R , Entwistle, John

Journal of NeuroInterventional Surgery | May 11, 2021 | Volume: 14 | Issue: 4 | Pages: 356-361

10.1136/neurintsurg-2021-017310 Get It

Background Several animal studies have demonstrated that mechanical thrombectomy (MT) for acute ischemic stroke (AIS) may cause vessel wall injury (VWI). However, the histological changes in human cerebral arteries following MT are difficult to determine. Objective To investigate the occurrence of VWI during MT by histological and immunohistochemical evaluation of AIS clots. Methods As part of the multicenter STRIP registry, 277 clots from 237 patients were analyzed using Martius Scarlett Blue stain and immunohistochemistry for CD34 (endothelial cells) and smooth muscle actin (smooth muscle cells). Results MT devices used were aspiration catheters (100 cases), stentriever (101 cases), and both (36 cases). VWI was found in 33/277 clots (12%). There was no significant correlation between VWI and MT device. The degree of damage varied from grade I (mild intimal damage, 24 clots), to grade II (relevant intimal and subintimal damage, 3 clots), and III (severe injury, 6 clots). VWI clots contained significantly more erythrocytes (p=0.006*) and less platelets/other (p=0.005*) than non-VWI clots suggesting soft thrombus material. Thrombolysis correlated with a lower rate of VWI (p=0.04*). VWI cases showed a significantly higher number of passes (2 [1–4] vs 1 [1–3], p=0.028*) and poorer recanalization outcome (p=0.01*) than cases without VWI. Conclusions Histological markers of VWI were present in 12% of AIS thrombi, suggesting that VWI might be related to MT. VWI was associated with soft thrombus consistency, higher number of passes and poorer revascularization outcome. There was no significant correlation between VWI and MT device.
Preclinical testing platforms for mechanical thrombectomy in stroke: a review on phantoms, in-vivo animal, and cadaveric models
Liu, Yang , Abbasi, Mehdi , Larco, Jorge Arturo , Kadirvel, Ramanathan , Kallmes, David F. , Brinjikji, Waleed , Arturo Larco, Jorge L, Savastano, Luis , Arturo Larco, Jorge L , Liu, Yang

Journal of NeuroInterventional Surgery | March 15, 2021 | Volume: 13 | Issue: 9 | Pages: 816-822

10.1136/neurintsurg-2020-017133 Get It

Preclinical testing platforms have been instrumental in the research and development of thrombectomy devices. However, there is no single model which fully captures the complexity of cerebrovascular anatomy, physiology, and the dynamic artery-clot-device interaction. This article provides a critical review of phantoms, in-vivo animal, and human cadaveric models used for thrombectomy testing and provides insights into the strengths and limitations of each platform. Articles published in the past 10 years that reported thrombectomy testing platforms were identified. Characteristics of each test platform, such as intracranial anatomy, artery tortuosity, vessel friction, flow conditions, device-vessel interaction, and visualization, were captured and benchmarked against human cerebral vessels involved in large-vessel occlusion stroke. Thrombectomy phantoms have been constructed from silicone, direct 3D-printed polymers, and glass. These phantoms represent oversimplified patient-specific cerebrovascular geometry but enable adequate visualization of devices and clots under appropriate flow conditions. They do not realistically mimic the artery-clot interaction. For the animal models, arteries from swine, canines, and rabbits have been reported. These models can reasonably replicate the artery-clot-device interaction and have the unique value of evaluating the safety of thrombectomy devices. However, the vasculature geometries are substantially less complex and flow conditions are different from human cerebral arteries. Cadaveric models are the most accurate vascular representations but with limited access and challenges in reproducibility of testing conditions. Multiple test platforms should be likely used for comprehensive evaluation of thrombectomy devices. Interpretation of the testing results should take into consideration platform-specific limitations.