Abstract 99: Clot Composition And Reperfusion Outcomes In 1430 Mechanical Thrombectomy Patients: Analysis Of The Stroke Thromboembolism Registry Of Imaging And Pathology
Background: Understanding clot composition may allow for better technical planning and improved outcomes in mechanical thrombectomy (MT). We sought to correlate clot composition with reperfusion outcomes in MT. Methods: Clinical, imaging, and clot data from patients enrolled in the STRIP Registry from September 2016 to September 2020 were analyzed. Samples were fixed in 10% phosphate-buffered formalin and stained with hematoxylin and eosin and Martius Scarlett Blue. Percent composition, richness, and gross appearance were evaluated. Outcome measures included the rate of First-Pass Effect (mTICI2c/3, FPE) and the number of device passes. Results: A total of 1430 patients (mean age, 68.4±13.5years; median [IQR] baseline NIHSS,17.2 [10.5-23]; IV-tPA use, 36%; Stent-Retrievers [SR], 27%; Contact Aspiration [CA], 27%; Combined SR + CA, 43%) were included. The median [IQR] number of passes was 1 [1-2]. FPE was achieved in 39.3% of the cases. There was no association between percent histological composition or clot richness and FPE in the overall population. However, the combined technique resulted in lower FPE rates for RBC-rich (P<0.0001), platelet-rich (P=0.003), and mixed (P<0.0001) clots. Fibrin-rich and platelet-rich clots required a higher number of passes compared to RBC-rich and mixed clots (median, 2 and 1.5 vs.1, respectively, P=0.02). CA displayed a trend towards a higher number of passes with fibrin-rich clots (2 vs.1, P=0.12). By gross appearance, mixed/heterogeneous clots had lower FPE rates than red and white clots. Conclusion: Despite the lack of correlation between clot histology and FPE in the overall population, our study adds to the growing body of evidence supporting the notion that clot composition influences reperfusion treatment strategy outcomes. Additional studies are needed.
Background: We performed a multicenter prospective clinical registry across 11 centers to study the association between histopathological characteristics of retrieved clots and imaging, stroke etiology and clinical outcomes. Materials and Methods: Following IRB approval at the 11 centers, patients were enrolled in the STRIP registry. All retrieved emboli were sent for histopathological analysis with H&E and MSB staining. Demographic variables, comorbidities, stroke etiology, imaging findings and procedural details were collected for each case. We studied the association between clot histopathology and imaging findings, stroke etiology and and revascularization outcomes. Student’s t-test was used for continuous variables and chi-squared testing for categorical variables. Results: To date, 1022 patients have been included. There was a significant correlation between platelet rich clots and the absence of hyperdensity on non-contrast CT [p=0.321, p=0.003) and a significant inverse correlation between the percentage of platelets and mean HU on NCCT (p=-0.243, p=0.025). The proportion of platelet-rich clots (55.0% versus 21.2%, p=0.005) and the percentage of platelet content (22.1% versus 13.9%, p=0.03) was significantly higher in patient with large artery atherosclerosis compared to those with a cardioembolic etiology. There was no correlation between RBC density, WBC density, fibrin density or platelet density and revascularization outcomes with stent-retrievers. However, we have found that with aspiration alone, patients with platelet rich clots are less likely to be fully revascularized (i.e. TICI 2c/3) than non-platelet rich clots (OR=0.36, 95%CI=0.12-0.81, P<.0001). Meanwhile, patients with RBC rich clots are more likely to be completely revascularized with aspiration alone than those with RBC poor clots (OR=2.71, 95%CI=1.25-3.24, P=0.02). Conclusions: Interim analysis of the STRIP registry suggests that the platelet content of a clot may be the most revealing factor in determining a clot’s etiology, imaging features and revascularization outcome. Platelet rich clots are less dense on NCCT, are associated with a large artery atherosclerosis source and are less likely to be completely revascularized with aspiration alone.
Histological evaluation of acute ischemic stroke thrombi may indicate the occurrence of vessel wall injury during mechanical thrombectomy
Background Several animal studies have demonstrated that mechanical thrombectomy (MT) for acute ischemic stroke (AIS) may cause vessel wall injury (VWI). However, the histological changes in human cerebral arteries following MT are difficult to determine. Objective To investigate the occurrence of VWI during MT by histological and immunohistochemical evaluation of AIS clots. Methods As part of the multicenter STRIP registry, 277 clots from 237 patients were analyzed using Martius Scarlett Blue stain and immunohistochemistry for CD34 (endothelial cells) and smooth muscle actin (smooth muscle cells). Results MT devices used were aspiration catheters (100 cases), stentriever (101 cases), and both (36 cases). VWI was found in 33/277 clots (12%). There was no significant correlation between VWI and MT device. The degree of damage varied from grade I (mild intimal damage, 24 clots), to grade II (relevant intimal and subintimal damage, 3 clots), and III (severe injury, 6 clots). VWI clots contained significantly more erythrocytes (p=0.006*) and less platelets/other (p=0.005*) than non-VWI clots suggesting soft thrombus material. Thrombolysis correlated with a lower rate of VWI (p=0.04*). VWI cases showed a significantly higher number of passes (2 [1–4] vs 1 [1–3], p=0.028*) and poorer recanalization outcome (p=0.01*) than cases without VWI. Conclusions Histological markers of VWI were present in 12% of AIS thrombi, suggesting that VWI might be related to MT. VWI was associated with soft thrombus consistency, higher number of passes and poorer revascularization outcome. There was no significant correlation between VWI and MT device.
Per pass analysis of thrombus composition retrieved by mechanical thrombectomy
Background and aim Mechanical thrombectomy (MT) for large vessel occlusion often requires multiple passes to retrieve the entire thrombus load. In this multi-institutional study we sought to examine the composition of thrombus fragments retrieved with each pass during MT. Methods Patients who required multiple passes during thrombectomy were included. Histopathological evaluation of thrombus fragments retrieved from each pass was performed using Martius Scarlet Blue staining and the composition of each thrombus component including RBC, fibrin and platelet was determined using image analysis software. Results 154 patients underwent MT and 868 passes was performed which resulted in 263 thrombus fragments retrieval. The analysis of thrombus components per pass showed higher RBC, lower fibrin and platelet composition in the pass 1 and 2 when compared to pass 3 and passes 4 or more combined (P values <0.05). There were no significant differences between thrombus fragments retrieved in pass 1 and pass 2 in terms of RBC, WBC, fibrin, and platelet composition (P values >0.05). Similarly, when each composition of thrombus fragments retrieved in pass 3 and passes 4 or more combined were compared with each other, no significant difference was noted (P values >0.05). Conclusion Our findings confirm that thrombus fragments retrieved with each pass differed significantly in histological content. Fragments in the first passes were associated with lower fibrin and platelet composition compared to fragments retrieved in passes three and four or higher. Also, thrombus fragments retrieved after failed pass were associated with higher fibrin and platelet components.
O-003 Results of the stroke thromboembolism registry of imaging and pathology: a multicenter international study
Background and Purpose— Nearly 30% of large vessel occlusion acute ischemic stroke clots are from an unknown source. We assessed histological clot composition in a series of patients with large vessel occlusion and investigated correlations between clot composition and stroke pathogenesis. Methods— As part of the multi-institutional STRIP registry (Stroke Thromboembolism Registry of Imaging and Pathology), consecutive emboli retrieved during mechanical thrombectomy were stained using Martius Scarlett Blue and analyzed using machine learning software. We assessed proportions of red blood cells, fibrin, platelets, and white blood cells. Correlations between clot components and stroke pathogenesis (large artery atherosclerosis, cardioembolism, and stroke of undetermined pathogenesis) were assessed using SPSS22. Results— One hundred five patients were included. The proportion of platelet-rich clots (55.0% versus 21.2%; P =0.005) and percentage of platelet content (22.1±4.2% versus 13.9±14.2%; P =0.03) was significantly higher in the large artery atherosclerosis group compared with the cardioembolic group. The proportion of platelet-rich clots (50.0% versus 21.2%; P =0.024) was also significantly higher in the cryptogenic group compared with cardioembolic cases. Large artery atherosclerosis and cryptogenic cases had a similar proportion of platelet-rich clots (55.0% versus 50.0%; P =0.636). There was no significant difference between stroke pathogenesis and the other major clot components. Conclusions— High platelet content of emboli is associated with a large artery atherosclerosis etiology of large vessel occlusion.
Angioplasty of an Idiopathic Intracranial Arterial Stenosis
Treatment of symptomatic intracranial atherosclerotic stenosis usually involves maximizing medical therapy. In patients with medically refractory symptoms despite maximum pharmacologic therapy, intracranial angioplasty and/or stenting has become an accepted treatment option. The use of percutaneous transluminal angioplasty (PTA) for idiopathic intracranial stenoses has not been reported to date. We describe a case of idiopathic intracranial stenosis which was refractory to medical therapy and was successfully treated with percutaneous transluminal angioplasty. The presenting symptoms included multiple episodes of aphasia and right-sided weakness as well as a left basal ganglia infarct. The patient underwent treatment with two intracranial angioplasty procedures. There was a recurrence of the stenosis and symptoms following the first procedure. However, after a second treatment with a slightly larger balloon, flow in the MCA normalized. Furthermore, the symptoms attributed to her MCA stenosis had essentially resolved. This case suggests that patients with medically refractory idiopathic intracranial stenosis can be successfully treated with percutaneous transluminal angioplasty.
Cerebral Aneurysm Perforations during Treatment with Detachable Coils
Perforation of intracranial aneurysms during endovascular treatment with platinum micro-coils is a well-known and serious complication reported to occur in 2–4% of patients. Inflation of a remodelling balloon across the aneurysm neck or within the proximal parent vessel is an additional technique that theoretically might be useful to reduce flow within the aneurysm and achieve hemostasis. In the case reports that follow, we present our experience using this technique for managing intraprocedural aneurysm rupture.
Intracranial Aneurysm Enlargement on Serial Magnetic Resonance Angiography
Background and Purpose— Size of an unruptured intracranial aneurysm (UIA) may be an important risk factor for rupture. Accordingly, serial noninvasive imaging is commonly used to assess untreated UIA for enlargement. Few data exist regarding the frequency and predictors of enlargement. We obtained this information from a group of patients followed with serial MR angiography (MRA). Methods— We retrospectively identified 165 patients with 191 UIA followed with serial MRA. Fusiform aneurysms, UIA <2 mm, and UIA that were surgically or endovascularly treated before the first MRA were excluded. MRA was performed using 1.5-T and 3-T MRI. Maximal diameter was determined on MRA source images. Multivariate regression analysis was used to determine independent risk factors for growth. Results— Twenty aneurysms (10%) grew over a median follow-up period of 47 months. Frequency of enlargement was 6.9%, 25%, and 83% for aneurysms <8 mm, 8 to 12 mm, and ≥13 mm, respectively ( P <0.001 for trend). Of the variables we evaluated, original aneurysm diameter (OR, 1.28 per mm; 95% CI, 1.07 to 1.58) was the only independent predictor of enlargement. Aneurysms ≥8 mm in diameter were at highest risk for enlargement (OR, 7.25; 95% CI, 1.96 to 27.1). There was a trend toward increased risk of enlargement in patients with multiple aneurysms (OR, 2.50; 95% CI, 0.86 to 7.53). Conclusions— Over a median follow-up period of 47 months, 10% of UIA enlarged. Larger aneurysms had a significantly increased risk of enlargement. The likelihood of enlargement was highest in aneurysms with diameters ≥8 mm. However, a clinically significant proportion of small aneurysms grow, and this growth can be detected by serial MRA.