Back to Authors

Matsumoto, Jane M.

Mayo Clinic

Mayo Clinic

Citations 21

Virtual Surgical Planning and Applications in Plastic and Craniomaxillofacial Surgery
Basel, Sharaf, Matsumoto, Jane M., Lachman, Nirusha , Bite, Uldis

The FASEB Journal | November 26, 2023 | Volume: 30 | Issue: S1 | Pages: No page available

10.1096/fasebj.30.1_supplement.92.3 Get It

Advanced plastic and craniomaxillofacial reconstruction is a multidisciplinary field, requiring communication and accurate planning among various specialists including oncologic surgeons, plastic surgeons, and radiologists. Complex defects may present in pediatric congenital deformities, after trauma or oncologic surgery. Restoration of form and function require precise planning among the various specialists involved and accurate execution of the surgical plan. Often, considerations for bony and soft tissue requirements make the reconstruction more challenging. Virtual surgical planning using computed tomographic imaging, 3D surface imaging technology and computer‐aided design allow the surgeons to perform virtual surgery and generate templates and cutting guides that allow for the precise and expedient recreation of the plan in the operating room. The author presents cases highlighting various reconstructive requirements where virtual planning was used for advanced plastic and craniomaxillofacial reconstruction to achieve precise reconstruction. Support or Funding Information None
Workflow to develop 3D designed personalized neonatal CPAP masks using iPhone structured light facial scanning
Kamath, A. , Kamath, Marielle J., Ekici, Selin , Stans, Anna Sofia, Colby, Christopher E. , Matsumoto, Jane M., Wylam, Mark E.

No container title available | April 25, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-1578678/v1 Get It

Abstract Background Continuous positive airway pressure (CPAP) is a common mode of respiratory support used in neonatal intensive care units. In preterm infants, nasal CPAP (nCPAP) therapy is often delivered via soft, biocompatible nasal mask suitable for long-term direct-skin contact and held firmly against face. Limited sizes of nCPAP mask contribute to mal-fitting related complications and adverse outcomes in this fragile population. We hypothesized that custom-fit nCPAP masks will improve the fit with less skin pressure and strap tension improving efficacy and reducing complications associated with nCPAP therapy in neonates. Methods After IRB approval and informed consent we evaluated several methods to develop 3D facial models to test custom 3D nCPAP masks. These methods included camera-based photogrammetry, laser scanning and structured light scanning using a Bellus3D Face Camera Pro and iPhone X running either Bellus3D FaceApp for iPhone, or Heges application. This data was used to provide accurate 3D neonatal facial models. Using CAD software nCPAP inserts were designed to be placed between proprietary nCPAP mask and the model infant’s face. The resulted 3D designed nCPAP mask was form fitted to the model face. Subsequently, nCPAP masks were connected to a ventilator to provide CPAP and calibrated pressure sensors and co-linear tension sensors were placed to measures skin pressure and nCPAP mask strap tension. Results Photogrammetry and laser scanning were not suited to the neonatal face. However, structured light scanning techniques produced accurate 3D neonatal facial models. Individualized nCPAP mask inserts manufactured using 3D printed molds and silicon injection were effective at decreasing surface pressure and mask strap pressure in some cases by more than 50% compared to CPAP masks without inserts. Conclusions We found that readily available structured light scanning devices such as the iPhoneX are a low cost, safe, rapid, and accurate tool to develop accurate models of preterm infant facial topography. Structured light scanning developed 3D nCPAP inserts applied to commercially available CPAP masks significantly reduced skin pressure and strap tension at clinically relevant CPAP pressures when utilized on model neonatal faces. This workflow maybe useful at producing individualized nCPAP masks for neonates reducing complications due to malfit.
Three-Dimensional-Printed Liver Model Helps Learners Identify Hepatic Subsegments: A Randomized-Controlled Cross-Over Trial
Chedid, Victor , Kamath, A. , Knudsen, John M. , Frimannsdottir, Katrin R., Yost, Kathleen J. , Geske, Jennifer R. , Taner, Timuçin , Matsumoto, Jane M., Kamath, Patrick S. , Chedid, Victor G , Kamath, Amika A, M Knudsen, John, Frimannsdottir, Katrin, R Geske, Jennifer, Geske, Jennifer , Morris, Jonathan M.

American Journal of Gastroenterology | September 25, 2020 | Volume: 115 | Issue: 11 | Pages: 1906-1910

10.14309/ajg.0000000000000958 Get It

INTRODUCTION: The purpose of this study was to find out whether 3-dimensional (3D)–printed models improved the learners' ability to identify liver segments. METHODS: A total of 116 physicians from 3 disciplines were tested in a cross-over trial at baseline and after teaching with 3D models and 2-dimensional (2D) images. Adjusted multilevel-mixed models were used to compare scores at baseline and after 3D and 2D. RESULTS: Accuracy in identifying hepatic segments was higher with 3D first than 2D (77% vs 69%; P = 0.05) and not significantly improved by a combination of 3D and 2D. Increased confidence in segment identification was highest in trainees after 3D ( P = 0.04). DISCUSSION: 3D-printed models facilitate learning hepatic segmental anatomy.
Finite Element Analysis of the Septal Cartilage L-Strut
Menapace, Deanna C., Carlson, Kent, Dragomir‐Daescu, Dan , Matsumoto, Jane M., Carlson, Kent D, Matsumoto, Jane, Hamilton, Grant

Facial Plastic Surgery & Aesthetic Medicine | July 28, 2020 | Volume: 23 | Issue: 2 | Pages: 90-97

10.1089/fpsam.2019.0012 Get It

Importance: Septoplasty is one of the most commonly performed operations in the head and neck. However, the reasons for septoplasty failure and the additional stress of performing a chondrotomy on the septal cartilage are not well understood. Design, Setting, and Participants: A finite element model of the nasal septum was created using a microcomputed tomography scan of the nasoseptal complex that was reconstructed into a three-dimensional model in silico. Testing included four common chondrotomy designs: traditional L-strut, double-cornered chondrotomy (DCC), curved L-strut, and the C-curve. Tip displacement was applied in a vector parallel to the caudal strut to simulate nasal tip palpation. Main Outcomes and Measures: With finite element analysis, the maximum principal stress (MPS), von Mises stress (VMS), harvested cartilage volume, and surface area were recorded. Results: The highest MPS for the L-strut, DCC, curved L-strut, and C-curve was identified at the corner of the chondrotomy. The MPS at the corner of the chondrotomy was reduced 44% when comparing the C-curve with the traditional L-strut. The VMS patterns showed compressive stress along the caudal septum in all models, but at the corner, the stresses were highest in the chondrotomies designed with sharp-angled corners. The VMS showed a 76% decrease when comparing the C-curve with the traditional L-strut. The stress across the anterior septal angle is also higher in models with sharp-angled corners. Cartilage harvest volumetric and surface area assessments did not show meaningful differences between shapes. Conclusions and Relevance: The highest area of stress is near the transition of the dorsal to caudal septum in all models. Stresses are relatively higher in chondrotomy shapes that contain sharp-angled corners. The relative reduction in MPS and VMS utilizing a C-curve instead of an L-strut may decrease the likelihood that the septum will deform or fail in this region. The volume and surface area of the C-curve are similar to that of the L-strut technique. Avoiding sharp-angled corners reduces the stresses at the corner of the chondrotomy and across the anterior septal angle. Using a C-curve may be an improved septoplasty design.
Three-Dimensional Printing: Current Use in Rhinology and Endoscopic Skull Base Surgery
Low, Christopher M. , Matsumoto, Jane S., Stokken, Janalee K., O’Brien, Erin K. , O'Brien, Erin K., O'Brien, Erin K , Morris, Jonathan M. , Price, Daniel L. , Matsumoto, Jane M., Choby, Garret

American Journal of Rhinology & Allergy | August 5, 2019 | Volume: 33 | Issue: 6 | Pages: 770-781

10.1177/1945892419866319 Get It

Background In the discipline of rhinology and endoscopic skull base surgery (ESBS), 3-dimensional (3D) printing has found meaningful application in areas including preoperative surgical planning as well as in surgical education. However, its scope of use may be limited due to the perception among surgeons that there exists a prohibitively high initial investment in resources and time to acquire the requisite technical expertise. Nevertheless, given the ever decreasing cost of advancing technology coupled with the need to understand the complex spatial relationships of the paranasal sinuses and skull base, the use of 3D printing in rhinology and ESBS is poised to blossom. Objective Help the reader identify current or potential future uses of 3D printing technology relevant to their rhinologic clinical or educational practice. Methods A review of published literature relating to 3D printing in rhinology and ESBS was performed. Results Results were reviewed and organized into 5 overarching categories including an overview of the 3D printing process as well as applications of 3D printing including (1) surgical planning, (2) custom prosthetics and implants, (3) patient education, and (4) surgical teaching and assessment. Conclusion In the discipline of rhinology and ESBS, 3D printing finds use in the areas of presurgical planning, patient education, prosthesis creation, and trainee education. As this technology moves forward, these products will be more broadly available to providers in the clinical and educational setting. The possible applications are vast and have great potential to positively impact surgical training, patient satisfaction, and most importantly, patient outcomes.
Use of 3D‐Printed and 2D‐Illustrated International Frontal Sinus Anatomy Classification Anatomic Models for Resident Education
Low, Christopher M. , Matsumoto, Jane S., Stokken, Janalee K., O’Brien, Erin K. , O'Brien, Erin K., O'Brien, Erin K , Morris, Jonathan M. , Matsumoto, Jane M., Choby, Garret

Otolaryngology–Head and Neck Surgery | July 9, 2019 | Volume: 161 | Issue: 4 | Pages: 705-713

10.1177/0194599819860832 Get It

ObjectiveTo examine the impact of 2‐dimensional (2D) illustrations and 3‐dimensonal (3D)–printed anatomic models of the frontal sinuses according to the International Frontal Sinus Anatomy Classification in the education of otolaryngology and radiology residents.Study DesignA crossover study design with half of the study participants randomized to the 2D illustration intervention first and the other half randomized to the 3D‐printed model first.SettingRegularly scheduled resident didactic lectures at a tertiary care center.Subjects and MethodsForty‐one otolaryngology and radiology residents were assessed with pre‐ and postintervention questionnaires that included subjective and objective methods of assessment.ResultsOverall, there was a statistically significant improvement in total number of answers correct and in confidence score between the pre‐ and postintervention assessments (P <. 0001). The primary outcome of order of intervention (ie, 2D → 3D vs 3D → 2D) did not result in statistically significant differences in postevaluation scores. In regard to the secondary outcome of learner preference for educational modality, radiology residents favored the 2D illustrations to understand anatomic relationships, while otolaryngology residents preferred the 3D model to be more helpful in surgical planning (P =. 0075).ConclusionThere is no difference between 2D‐illustrated and 3D‐printed International Frontal Sinus Anatomy Classification anatomic models in overall educational outcome, despite the preference of learners. Together, these models can be used as helpful tools in frontal sinus education for otolaryngology and radiology trainees.
Preoperative Planning Using 3-Dimensional Printing for Complex Paraspinal Schwannoma Resection: 2-Dimensional Operative Video
Stone, Jonathan J. , Matsumoto, Jane M., Spinner, Robert J. , Morris, Jonathan M.

Operative Neurosurgery | August 30, 2018 | Volume: 16 | Issue: 3 | Pages: E80-E80

10.1093/ons/opy239 Get It

Abstract Schwannomas are benign peripheral nerve sheath tumors that are typically round, smooth, and straightforward to resect. Occasionally they are more complicated to resect because of their size, location, degree of bony erosion, and vascular or neural compression. These complex lesions frequently require multidisciplinary surgical teams in order to decrease surgical morbidity. Historically, surgical planning consisted of imaging review and verbal communication among team members. 3-dimensional (3D) printing offers a new method for preoperative planning and is becoming more popular in Neurosurgery. This video demonstrates the use of 3D printing for complex paraspinal tumors in the cervical, thoracic, and sacral regions. The Institutional Review Board Office for Human Research Protection does not require approval for single participant case studies, or a case series with multiple participants. The subjects involved in this study were not identifiable and the general surgical consent form included permission for intraoperative photos.
The breadth of the diaphragm: updates in embryogenesis and role of imaging
Koo, Chi Wan , Johnson, Tucker F. , Gierada, David S. , White, Darin , Matsumoto, Jane M., Levin, David L. , White, Darin B, Blackmon, Shanda, Choe, Jooae, Allen, Mark S. , Kuzo, Ronald S. , Blackmon, Shanda , Choe, Jooae

The British Journal of Radiology | February 27, 2018 | Volume: No volume available | Issue: No issue available | Pages: 20170600

10.1259/bjr.20170600 Get It

Three‐dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification
Sabbagh, Abdallah El , Eleid, Mackram F. , Matsumoto, Jane M., Anavekar, Nandan S., Al‐Hijji, Mohammed , Said, Sameh M. , Holmes, David R. , Rihal, Charanjit S. , Foley, Thomas A. , El Sabbagh, Abdallah , Al-Hijji, Mohammed A , Nkomo, Vuyisile T. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | January 23, 2018 | Volume: 92 | Issue: 7 | Pages: No page available

10.1002/ccd.27488 Get It

AbstractIntroductionThree‐dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR).MethodsEight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre‐procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result.Results3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post‐procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model.Conclusion3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.
Management of pediatric hepatocellular carcinoma: A multimodal approach
Kohorst, Mira A. , Matsumoto, Jane M., El‐Youssef, Mounif, Arndt, Carola A.S., Rodriguez, Vilmarie , Rao, Amulya A. Nageswara , Warad, Deepti M, El-Youssef, Mounif, Nageswara Rao, Amulya A , Warad, Deepti , Heimbach, Julie K.

Pediatric Transplantation | June 20, 2017 | Volume: 21 | Issue: 6 | Pages: No page available

10.1111/petr.13007 Get It

AbstractHCC is rare in the pediatric population, but is the second most common liver malignancy in children. Survival rates for primary unresectable HCC have been dismal. The objective of this study was to describe our experience with a multimodal approach for the management of unresectable HCC in two adolescent patients and to review the literature. Both patients are currently alive with no recurrence at 51 and 29 months post‐transplant. Multimodality treatment involving chemotherapy with doxorubicin, cisplatin, and sorafenib; TACE; timely liver transplantation; and post‐transplant therapy with sorafenib and mTOR inhibitors may help improve outcomes and prolong survival in pediatric patients with unresectable HCC.