Back to Authors

Al-Hijji, Mohammed A

0000-0002-9572-7688

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.

Citations 21

Role of Biological Age in the Determination of Long‐Term Cause‐Specific Death Following Percutaneous Coronary Interventions
Singh, Mandeep , Friedman, Paul A. , Gulati, Rajiv , Sabbagh, Abdallah El , Lewis, B , Kanwar, Amrit , Raphael, Claire E. , Al‐Hijji, Mohammed , Attia, Zachi I. , Behfar, Atta , Kirkland, James L. , El Sabbagh, Abdallah , Lewis, Bradley R , Al-Hijji, Mohammed A , Behfar, Atta , Raphael, Claire , Attia, Zachi I

Journal of the American Heart Association | February 26, 2025 | Volume: 14 | Issue: 5 | Pages: No page available

10.1161/jaha.124.036876 Get It

Background We tested whether biologic age, as estimated by deficits, functional impairments, or Age‐Gap or their combination, provide improved estimation of cause‐specific death as compared with chronological age. Methods Cardiovascular and noncardiovascular deficits, functional impairments, and Age‐Gap were prospectively collected in 535 patients aged ≥55 years undergoing percutaneous coronary interventions between August 1, 2014, and March 31, 2018. Age‐Gap was calculated as the difference between chronological age and age estimated by artificial intelligence ECG using a convolutional neural network. The full biological age model included deficits, functional impairments, and Age‐Gap >2 SD. A multivariable reduced model with the least number of variables was also created to provide a comparable C index to the full model. Results The average chronological age was 72.1±9.5 years, and there were 68% of men. During a median follow‐up of 2.61 years, 124 (23%) patients died. There was a modest correlation between Age‐Gap and biological age ( r =0.28 [95% CI, 0.20–0.35]; P <0.001). When modeled with chronologic age as a covariate, Age‐Gap predicted all‐cause (hazard ratio [HR], 1.07 [95% CI, 1.04–1.10]; P <0.001) and cardiovascular (HR, 1.07 [95% CI, 1.04–1.11]; P <0.001) mortality. As compared with chronological age, the full biological age model noted significant improvement in the prediction of long‐term overall (95% CI, 0.65–0.78), cardiovascular (95% CI, 0.69–0.77), and noncardiovascular (95% CI, 0.55–0.86) mortality. In the reduced models, most prognostic information for noncardiovascular mortality (C index: 0.79) was obtained by subjective difficulty in performing tasks, whereas the deficit‐based estimation predicted cardiovascular mortality (C index: 0.72). Conclusions Estimated biological age from deficits and functional impairments was superior to chronological age in predicting long‐term cause‐specific mortality following percutaneous coronary interventions.
The impact of pulmonary hypertension on outcomes of transcatheter mitral valve replacement in mitral annular calcification
Cajigas, Héctor , Kaptzan, Tatiana, Lewis, Bradley R., El‐Sabbagh, Abdallah, Al‐Hijji, Mohammed , Eleid, Mackram F. , Wang, Dee Dee , Eng, Marvin H. , Kodali, Susheel , Chakravarty, Tarun , O’Hair, Daniel, Jones, Noah, Makkar, Raj , Reisman, Mark, Leon, Martin B. , Rihal, Charanjit S. , Cajigas, Hector R , Eleid, Mackram F , Wang, Dee Dee , Pershad, Ashish , Rihal, Charanjit, Guerrero, Mayra E , Al-Hijji, Mohammed A , Alkhouli, Mohamad , George, Isaac , Pershad, Ashish , O’Neill, William W. , Rihal, Charanjit S. , Guerrero, Mayra

Catheterization and Cardiovascular Interventions | January 12, 2022 | Volume: 99 | Issue: 5 | Pages: 1647-1658

10.1002/ccd.30057 Get It

AbstractObjectivesTo assess the impact of pulmonary hypertension (PH) on outcomes of patients with severe mitral annular calcification (MAC) undergoing transcatheter mitral valve replacement (TMVR).BackgroundPH is associated with poor outcomes after mitral valve surgery. Whether the presence of PH in patients with MAC undergoing (TMVR) is associated with poor outcomes, is unknown.MethodsRetrospective evaluation of 116 patients from 51 centers in 11 countries who underwent TMVR with valve in mitral annular calcification (ViMAC) using balloon‐expandable aortic transcatheter valves (THVs) from September 2012 to March 2017. Pulmonary artery systolic blood pressure (PASP) by echocardiogram was available in 90 patients. The subjects were stratified based on PASP: No PH = PASP ≤35 mmHg (n = 11); mild to moderate PH = PASP 36–49 mmHg (n = 21) and severe PH = PASP ≥50 mmHg (n = 58). Clinical, procedural, and echocardiographic outcomes were assessed.ResultsMean age was 72.7 (±12.8) years, 59 (65.6%) were female, Society of Thoracic Surgeons score was 15.8 + 11.8% and 90.0% where in New York Heart Association (NYHA) class III–IV. There was no significant difference in all‐cause mortality at 30 days (no PH = 27.3%, mild–moderate PH = 19.0%, severe PH = 31.6%; p = 0.55) or at 1 year (no PH = 54.5%, mild–moderate PH = 38.1%, severe PH = 56.1%; p = 0.36). No difference in adverse events, NYHA class or amount of residual mitral regurgitation at 1 year were observed between the groups.ConclusionThis study suggests that the presence of PH in patients with predominantly mitral stenosis with MAC undergoing TMVR does not impact mortality or adverse events. Further studies are needed to fully understand the effect of PH in this group of patients.
Predictors of Left Ventricular Outflow Tract Obstruction After Transcatheter Mitral Valve Replacement in Severe Mitral Annular Calcification: An Analysis of the Transcatheter Mitral Valve Replacement in Mitral Annular Calcification Global Registry
Sabbagh, Abdallah El , Al‐Hijji, Mohammed , Wang, Dee Dee , Eleid, Mackram F. , Ureña, Marina , Himbert, Dominique , Chakravarty, Tarun , Fang, Hao , Zahr, Firas , Dvir, Danny , Sardar, Muhammad , Cheema, Asim N. , Alnasser, Sami , Iyer, Vijay , Kaddissi, Georges, Webb, John G. , Makkar, Raj , Vahanian, Alec , Rihal, Charanjit S. , Eleid, Mackram F , Nejjari, Mohammed , Dvir, Danny , Rihal, Charanjit, Guerrero, Mayra E , Al-Hijji, Mohammed A , Wang, Dee Dee , Holzhey, David Michael , Pershad, Ashish , Nejjari, Mohammed , O’Neill, William W. , Rihal, Charanjit S. , Guerrero, Mayra

Circulation: Cardiovascular Interventions | October 19, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circinterventions.121.010854 Get It

Background: Several studies have evaluated preprocedural imaging predictors of left ventricular outflow tract obstruction (LVOTO) after transcatheter mitral valve replacement. The patient cohorts in these studies were heterogeneous and included patients with transcatheter mitral valve replacement in failed bioprostheses, annuloplasty rings, and severe mitral annular calcification (MAC). The goal of this study was to evaluate predictors of LVOTO specific to patients undergoing valve-in-MAC. Methods: This study included patients with severe MAC who underwent valve-in-MAC and had optimal quality preprocedural multidetector row computed tomography scans eligible for retrospective analysis. Baseline demographic, echocardiographic, and procedural data on these patients were collected. multidetector row computed tomography parameters were analyzed for association with LVOTO, defined as increase in mean LVOT gradient by ≥10 mm Hg with accompanying hemodynamic instability. Results: Seventy-one patients with optimal preprocedural computed tomography scans were included in this study (mean age, 72.5±13.5 years), 9 of which developed LVOTO (all female). Baseline mean LVOT area, neo-LVOT area (145.3 versus 270.9 mm 2 ; P =0.006), indexed neo-LVOT area (90.1 versus 157.4; P =0.05), and virtual transcatheter heart valve to septum distance (3.1 versus 6.9 mm; P =0.002) were lower in the LVOTO group. Expected % LVOT area reduction was higher in the latter group (58.3 versus 42.7%; P =0.008). In the univariable analysis, the baseline mean LVOT area, neo-LVOT area, indexed neo-LVOT area, and valve to septum distance were all significantly associated with LVOTO. Conclusions: The systolic mean LVOT area, neo-LVOT area, indexed neo-LVOT, expected percentage LVOT area reduction, and the valve to septum distance were associated with LVOTO after valve-in-MAC.
Temporal outcomes of transcatheter mitral valve replacement in native mitral valve disease with annular calcification
Al‐Hijji, Mohammed , El‐Hajj, Stephanie, Sabbagh, Abdallah El , Eleid, Mackram F. , Rihal, Charanjit S. , Guerrero, Mayra , Al-Hijji, Mohammed A , ElHajj, Stephanie, El Sabbagh, Abdallah , Alkhouli, Mohamad A, Eleid, Mackram F , Rihal, Charanjit, Guerrero, Mayra E , Alkhouli, Mohamad , Crestanello, Juan A. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | February 8, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/ccd.29515 Get It

Endovascular snare technique to facilitate delivery of self‐expanding valve during transcatheter aortic valve‐in‐valve replacement in angulated aortas: A case series
Rohm, Charlene L. , Farhat, Salman , Al‐Hijji, Mohammed , Greason, Kevin L. , Gulati, Rajiv , Sabbagh, Abdallah El , Greason, Kevin, El Sabbagh, Abdallah , Al-Hijji, Mohammed A , Goel, Kashish

Catheterization and Cardiovascular Interventions | January 15, 2021 | Volume: 97 | Issue: 4 | Pages: 736-742

10.1002/ccd.29459 Get It

AbstractBackgroundTranscatheter aortic valve‐in‐valve replacement (ViV) has been widely accepted as a less invasive alternative to treat failed aortic surgical or transcatheter bioprosthetic valves. Angulated aortas present an additional challenge, particularly when using self‐expanding transcatheter heart valves (SE‐THV).MethodsTwo patients with failed surgical bioprosthetic aortic valves and one patient with a failed transcatheter bioprosthetic aortic valve underwent transcatheter aortic ViV using SE‐THV. All were deemed high‐risk for surgical aortic valve replacement by a heart team. All three patients had initial failed SE‐THV delivery using a conventional approach with subsequent successful delivery using the endovascular snare technique.ResultsIn Cases 1 and 2, the SE‐THV was biased towards the greater curve of the angulated aorta and behind the outer frame of the bioprosthetic valve frame. An endovascular snare was deployed through a secondary left femoral artery access, and the valve delivery system was advanced through the snare in the ascending aorta. The snare was tightened around the SE‐THV capsule proximal to the hat‐marker, allowing deflection of the SE‐THV and successful delivery. In Case 3, the SE‐THV interacted with the tall frame of a failed SE‐THV. A snare via the left femoral artery was deployed in the descending artery. The SE‐THV was advanced through the snare, and both the snare and SE‐THV were advanced together to the ascending aorta where the SE‐THV was deflected and successfully delivered.ConclusionsThe endovascular snare technique is a feasible option for successful delivery of SE‐THV during transcatheter aortic ViV in failed transcatheter or surgical bioprosthetic valves in angulated aortas.
Transcatheter closure of coronary artery fistula: A 21‐year experience
El‐Sabawi, Bassim , Al‐Hijji, Mohammed , Eleid, Mackram F. , Cabalka, Allison K. , Ammash, Naser M., Dearani, Joseph A. , Bjarnason, Haraldur , Holmes, David R. , Rihal, Charanjit S. , Al-Hijji, Mohammed A , Cabalka, Allison , Bjarnason, Haraldur , Dearani, Joseph A. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | January 10, 2020 | Volume: 96 | Issue: 2 | Pages: 311-319

10.1002/ccd.28721 Get It

AbstractObjectivesTo evaluate the outcomes of transcatheter coronary artery fistula (CAF) closure and to identify anatomic/procedural factors that may impact outcomes.BackgroundDue to the rarity of CAF, reported experience with transcatheter closure remains limited and anatomic and procedural factors that may lead to unsuccessful closure, complications, or recanalization of CAF are unclear.MethodsAll patients who underwent transcatheter CAF closure at Mayo Clinic from 1997 to 2018 were retrospectively reviewed. CAF anatomic characteristics, procedural techniques, and clinical/angiographic outcomes were assessed.ResultsA total of 45 patients underwent transcatheter closure of 56 CAFs. The most commonly used devices were embolization coils in 40 (71.4%) CAFs, vascular occluders in 10 (17.8%), or covered stent in 2 (3.6%). Acute procedural success with no or trivial residual flow occurred in 50 (89.3%) CAFs. Residual flow was small in three (5.4%) and large in three (5.4%). Eight (17.8%) patients had complications, including device migration in three, intracranial hemorrhage from anticoagulation in one, and myocardial infarction (MI) in four. MI was a result of covered stent thrombosis or stagnation of flow after closure of large distal CAF. Twenty‐two patients with 27 CAFs had follow‐up angiography after successful index procedure at median time of 423 (IQ 97‐1348) days. Of these, 23 (85.2%) had no/trace flow and 4 had large flow from recanalization.ConclusionsTranscatheter CAF closure is associated with a favorable acute procedural success and complication rate in selected patients. Procedural success and risk for complication are highly dependent on CAF anatomy and closure technique.
Routine Continuous Electrocardiographic Monitoring Following Percutaneous Coronary Interventions
Al‐Hijji, Mohammed , Gulati, Rajiv , Bell, Malcolm R. , Kaplan, Revelee J., Feind, Jeanna L., Lewis, Bradley R., Moriarty, James P. , Park, Jae Yoon , Sabbagh, Abdallah El , Kanwar, Ardaas, Barsness, Gregory W. , Munger, Thomas M. , Asirvatham, Samuel J. , Al-Hijji, Mohammed A , Bell, Malcolm, Borah, Bijan J. , Yoon Park, Jae, Barsness, Gregory, Munger, Thomas, Asirvatham, Samuel J , Kaplan, Revelee, Lerman, Amir , Singh, Mandeep

Circulation: Cardiovascular Interventions | December 30, 2019 | Volume: 13 | Issue: 1 | Pages: No page available

10.1161/circinterventions.119.008290 Get It

Background: The clinical utility of routine electrocardiographic monitoring following percutaneous coronary interventions (PCI) is not well studied. Methods: We prospectively evaluated the incidence, cost, and the clinical implications of actionable arrhythmia alarms on telemetry monitoring following PCI. One thousand three hundred fifty-eight PCI procedures (989 [72.8%] for acute coronary syndrome and 369 [27.2%] for stable angina) on patients admitted to nonintensive care unit were identified and divided into 2 groups; group 1, patients with actionable alarms (AA) and group 2, patients with non-AA. AA included (1) ≥3 s electrical pause or asystole; (2) high-grade Mobitz type II atrioventricular block or complete heart block; (3) ventricular fibrillation; (4) ventricular tachycardia (>15 beats); (5) atrial fibrillation with rapid ventricular response; (6) supraventricular tachycardia (>15 beats). Primary outcomes were 30-day all-cause mortality. Cost-savings analysis was performed. Results: Incidence of AA was 2.2% (37/1672). Time from end of procedure to AA was 5.5 (0.5, 24.5) hours. Patients with AA were older, presented with acute congestive heart failure or non–ST-segment–elevation myocardial infarction, and had multivessel or left main disease. The 30-day all-cause mortality was significantly higher in patients with AA (6.5% versus 0.3% in non-AA [ P <0.001]). Applying the standardized costing approach and tailored monitoring per the American Heart Association guidelines lead to potential cost savings of $622 480.95 for the entire population. Conclusions: AA following PCI were infrequent but were associated with increase in 30-day mortality. Following American Heart Association guidelines for monitoring after PCI can lead to substantial cost saving.
Safety and Risk of Major Complications With Diagnostic Cardiac Catheterization
Al‐Hijji, Mohammed , Lennon, Ryan J. , Gulati, Rajiv , Sabbagh, Abdallah El , Park, Jae Yoon, Crusan, Daniel J. , Kanwar, Amrit , Behfar, Atta , Holmes, David R. , Bell, Malcolm R. , Al-Hijji, Mohammed A , Crusan, Daniel, Bell, Malcolm, Behfar, Atta , Park, Jae Yoon, Lerman, Amir , Singh, Mandeep

Circulation: Cardiovascular Interventions | July 9, 2019 | Volume: 12 | Issue: 7 | Pages: No page available

10.1161/circinterventions.119.007791 Get It

Background: We aim to study the incidence of major complications related to procedure defined as in-hospital death, myocardial infarction, stroke, pericardial effusion or tamponade, percutaneous coronary intervention due to iatrogenic coronary dissection, or unplanned bypass surgery within 72 hours after diagnostic left heart catheterization (LHC; primary end point). Furthermore, all causes of in-hospital death after LHC were adjudicated and reported (secondary end point). Methods and Results: Diagnostic LHC procedures (aortic angiography; coronary, including graft, angiography; and left ventricular angiography) from January 1, 2002, through December 31, 2013, were identified using the clinical scheduling system at Mayo Clinic, Rochester, and complications were identified through electronic records. International Classification of Diseases, Ninth Revision billing codes were used. Registration was queried to identify all-cause mortality. All events were reviewed and adjudicated. There were 43 786 diagnostic LHC procedures; 97.3% were coronary angiograms. The mean age of patients was 64.5 years (13.6), and the majority were male (61.5%). Primary end point was seen in 36 (0.082%) procedures or 8.2 of 10 000 LHCs. Combined right sided procedures with LHC did not increase the risk of major complications. Cardiogenic and septic shock, cardiac arrhythmia, and postsurgical complication were the most common causes of in-hospital death after LHC. Conclusions: The overall rates of major complications related to diagnostic cardiac catheterization procedures are extremely rare. The majority of the deaths occurring post-diagnostic LHC procedures were secondary to acute illness rather than directly related to diagnostic procedure.
Outcomes of Patients With Severe Symptomatic Aortic Valve Stenosis After Chest Radiation: Transcatheter Versus Surgical Aortic Valve Replacement
Zhang, Dongfeng , Guo, Wei , Al‐Hijji, Mohammed , Sabbagh, Abdallah El , Lewis, Bradley R., Greason, Kevin L. , Sandhu, Gurpreet S. , Eleid, Mackram F. , Holmes, David R. , Herrmann, Joerg , Al-Hijji, Mohammed A , Greason, Kevin

Journal of the American Heart Association | May 24, 2019 | Volume: 8 | Issue: 10 | Pages: No page available

10.1161/jaha.119.012110 Get It

Background Patients with symptomatic severe aortic stenosis and a history of chest radiation therapy represent a complex and challenging cohort. It is unknown how transcatheter aortic valve replacement ( TAVR ) compares with surgical aortic valve replacement in this group of patients, which was the objective of this study. Methods and Results We retrospectively reviewed all patients with severe aortic stenosis who underwent either TAVR or surgical aortic valve replacement at our institution with a history of mediastinal radiation (n=55 per group). End points were echocardiographic and clinical outcomes in‐hospital, at 30 days, and at 1 year. Inverse propensity weighting analysis was used to account for intergroup baseline differences. TAVR patients had a higher STS score than surgical aortic valve replacement patients (5.1% [3.2, 7.7] versus 1.6% [0.8, 2.6], P <0.001) and more often ( P <0.01 for all) a history of atrial fibrillation (45.5% versus 12.7%), chronic lung disease (47.3% versus 7.3%), peripheral arterial disease (38.2% versus 7.3%), heart failure (58.2% versus 18.2%), and pacemaker therapy (23.6% versus 1.8%). Postoperative atrial fibrillation was less frequent (1.8% versus 27.3%; P <0.001) and hospital stay was shorter in TAVR patients (4.0 [2.0, 5.0] versus 6.0 [5.0, 8.0] days; P <0.001). The ratio of observed‐to‐expected 30‐day mortality was lower after TAVR as was 30‐day mortality in inverse propensity weighting–adjusted Kaplan–Meier analyses. Conclusions In patients with severe aortic stenosis and a history of chest radiation therapy, TAVR performs better than predicted along with less adjusted 30‐day all‐cause mortality, postoperative atrial fibrillation, and shorter hospitalization compared with surgical aortic valve replacement. These data support further studies on the preferred role of TAVR in this unique patient population.
Transapical percutaneous closure of rapidly expanding post‐surgical left ventricular outflow tract pseudoaneurysm
Al‐Hijji, Mohammed , Guerrero, Mayra , Rihal, Charanjit S. , Eleid, Mackram F. , Al-Hijji, Mohammed A , Guerrero, Mayra E , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | February 21, 2019 | Volume: 94 | Issue: 6 | Pages: 859-862

10.1002/ccd.28154 Get It

AbstractLeft ventricular pseudoaneurysm is an infrequent but potentially fatal complication following cardiac surgery, with spontaneous rupture being the most feared result. Moreover, surgical repair is associated with significant morbidity and mortality. We present a successful transapical percutaneous closure of a post‐surgical rapidly expanding left ventricular outflow tract (LVOT) pseudoaneurysm utilizing Amplatz Vascular Plug‐II (AVP‐II) (St. Jude Medical, St. Paul, MN) with the aid of 3D prototyping for pre‐procedural planning.