Back to Authors

El‐Sabawi, Bassim

https://orcid.org/0000-0001-5252-4293

Mayo Clinic

Mayo Clinic

Citations 11

Effect of eliminating pre‐discharge transthoracic echocardiogram on outcomes after TAVR
Welle, Garrett A. , El‐Sabawi, Bassim , Thaden, Jeremy J. , Greason, Kevin L. , Klarich, Kyle W. , Gulati, Rajiv , Rihal, Charanjit S. , Eleid, Mackram F. , Alkhouli, Mohamad A, Eleid, Mackram F , Welle, Garrett A , Nkomo, Vuyisile T. , Alkhouli, Mohamad , Guerrero, Mayra , Crestanello, Juan A. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | August 13, 2021 | Volume: 99 | Issue: 3 | Pages: 861-866

10.1002/ccd.29929 Get It

AbstractObjectivesThe aim of this study was to determine the safety of eliminating the pre‐discharge transthoracic echocardiogram (TTE) on 30‐day outcomes in patients undergoing transcatheter aortic valve replacement (TAVR).BackgroundTTE is utilized before, during, and after TAVR. Post‐procedural, pre‐discharge TTE assists in assessment of prosthesis function and detection of clinically significant paravalvular leak (PVL) after TAVR.MethodsPatients who underwent TAVR at Mayo Clinic from July 2018 to July 2019 were included in a prospective institutional registry. Patients undergoing TAVR prior to February 2019 received a pre‐discharge TTE, while those undergoing TAVR after February 2019 did not. Both cohorts were evaluated with TTE at 30 days post‐TAVR.ResultsA total of 330 consecutive patients were included. Of these, 160 patients (age 81.1 ± 7.6) had routine pre‐discharge TTE, while 170 patients (age 78.9 ± 7.5) were dismissed without routine pre‐discharge TTE. Mortality at 30 days was similar between the two groups (0% and 1.2%, respectively). One episode of PVL requiring intervention (0.6%) occurred in the pre‐discharge TTE group and none in the group without pre‐discharge TTE at 30‐day follow‐up. There was a similar incidence of total composite primary and secondary adverse events between the cohort receiving a pre‐discharge TTE and those without (28.1% vs. 25.3%, P = 0.56) at 30 days. The most common event was need for permanent pacemaker or ICD implantation in both groups (13.1% vs. 11.8%, P = 0.71).ConclusionsElimination of the pre‐discharge TTE is safe and associated with comparable 30‐day outcomes to routine pre‐discharge TTE. These findings have implication for TAVR practice cost‐efficiency and health care utilization.
Case report: acute myocarditis following the second dose of mRNA-1273 SARS-CoV-2 vaccine
Tailor, Prashant D. , Feighery, Aoife M. , El‐Sabawi, Bassim , Tailor, Prashant D , Prasad, Abhiram

European Heart Journal - Case Reports | August 4, 2021 | Volume: 5 | Issue: 8 | Pages: No page available

10.1093/ehjcr/ytab319 Get It

Abstract Background The SARS-CoV-2 pandemic has led to the development of the first mRNA vaccines used in humans. The vaccines are well tolerated, safe, and highly efficacious; however, post-marketing surveillance is revealing potential rare adverse effects. We report a case of symptomatic acute myocarditis following administration of the second dose of mRNA-1273 SARS-CoV-2 vaccine. Case summary A 44-year-old man presented with chest pain and ST-segment elevation 4 days after receiving the second dose of mRNA-1273 SARS-CoV-2 Vaccine. Emergent coronary angiogram showed minimal coronary artery disease. Cardiac magnetic resonance imaging confirmed acute myocarditis. Diagnosis of vaccine-associated myocarditis was made given the temporal relationship and supportive treatment initiated. Follow-up at 1 month confirmed complete symptomatic recovery and echocardiogram demonstrated normalization of cardiac function. Discussion Acute myocarditis should be considered in patients who present with chest pain or dyspnoea within days of receiving mRNA-1273 SARS-CoV-2 vaccination, especially after the second dose. This may be managed successfully with supportive therapies with complete recovery of cardiac function and symptoms. Further research is warranted to determine the mechanisms by which mRNA vaccines may cause myocarditis and for potential long-term cardiovascular injury.
Hemolysis after transcatheter mitral valve replacement in degenerated bioprostheses, annuloplasty rings, and mitral annular calcification: Incidence, patient characteristics, and clinical outcomes
El‐Sabawi, Bassim , Eleid, Mackram F. , Rihal, Charanjit S. , Eleid, Mackram F , Guerrero, Mayra , Nkomo, Vuyisile T. , Pislaru, Sorin V. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | May 31, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/ccd.29779 Get It

Temporal Incidence and Predictors of High‐Grade Atrioventricular Block After Transcatheter Aortic Valve Replacement
El‐Sabawi, Bassim , Welle, Garrett A. , Cha, Yong‐Mei , Espinosa, Raúl E. , Gulati, Rajiv , Sandhu, Gurpreet S. , Greason, Kevin L. , Friedman, Paul A. , Munger, Thomas M. , Rihal, Charanjit S. , Eleid, Mackram F. , Welle, Garrett A , Crestanello, Juan A. , Rihal, Charanjit S.

Journal of the American Heart Association | May 7, 2021 | Volume: 10 | Issue: 10 | Pages: No page available

10.1161/jaha.120.020033 Get It

Background The temporal incidence of high‐grade atrioventricular block (HAVB) after transcatheter aortic valve replacement (TAVR) is uncertain. As a result, periprocedural monitoring and pacing strategies remain controversial. This study aimed to describe the temporal incidence of initial episode of HAVB stratified by pre‐ and post‐TAVR conduction and identify predictors of delayed events. Methods and Results Consecutive patients undergoing TAVR at a single center between February 2012 and June 2019 were retrospectively assessed for HAVB within 30 days. Patients with prior aortic valve replacement, permanent pacemaker (PPM), or conversion to surgical replacement were excluded. Multivariable logistic regression was performed to assess predictors of delayed HAVB (initial event >24 hours post‐TAVR). A total of 953 patients were included in this study. HAVB occurred in 153 (16.1%). After exclusion of those with prophylactic PPM placed post‐TAVR, the incidence of delayed HAVB was 33/882 (3.7%). Variables independently associated with delayed HAVB included baseline first‐degree atrioventricular block or right bundle‐branch block, self‐expanding valve, and new left bundle‐branch block. Forty patients had intraprocedural transient HAVB, including 16 who developed HAVB recurrence and 6 who had PPM implantation without recurrence. PPM was placed for HAVB in 130 (13.6%) (self‐expanding valve, 23.7% versus balloon‐expandable valve, 11.9%; P <0.001). Eight (0.8%) patients died by 30 days, including 1 unexplained without PPM present. Conclusions Delayed HAVB occurs with higher frequency in patients with baseline first‐degree atrioventricular block or right bundle‐branch block, new left bundle‐branch block, and self‐expanding valve. These findings provide insight into optimal monitoring and pacing strategies based on periprocedural ECG findings.
Effect of a fourth‐generation transcatheter valve enhanced skirt on paravalvular leak
Welle, Garrett A. , El‐Sabawi, Bassim , Thaden, Jeremy J. , Greason, Kevin L. , Klarich, Kyle W. , Holmes, David R. , Rihal, Charanjit S. , Eleid, Mackram F. , Alkhouli, Mohamad A, Holmes, David R , Eleid, Mackram F , Welle, Garrett A , Nkomo, Vuyisile T. , Alkhouli, Mohamad , Guerrero, Mayra , Crestanello, Juan A. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | October 6, 2020 | Volume: 97 | Issue: 5 | Pages: 895-902

10.1002/ccd.29317 Get It

AbstractObjectivesThe aim of this study was to assess the 30 day incidence of paravalvular leak (PVL) and need for aortic valve reintervention of a fourth generation balloon expandable transcatheter valve with enhanced skirt (4G‐BEV) (SAPIEN 3 Ultra) compared with a third generation balloon expandable transcatheter valve (3G‐BEV) (SAPIEN 3).BackgroundThe incidence of PVL has steadily declined with iterative improvements in transcatheter aortic valve replacement (TAVR) technology and implantation strategies.MethodsPatients who underwent TAVR at Mayo Clinic from 7/2018 to 7/2019 were included in a prospective institutional registry. 4G‐BEV has been utilized since 2/2019, and, after this date, 3G‐BEV and 4G‐BEV were simultaneously used. 4G‐BEV had three sizes (20, 23, and 26 mm) while 3G‐BEV included four sizes (20, 23, 26, and 29 mm). Both cohorts were evaluated at 30 days post‐TAVR with a transthoracic echocardiogram to assess for PVL.ResultsA total of 260 consecutive patients were included. Of these, 101 patients received a 4G‐BEV and 159 patients received a 3G‐BEV. There were more females (p = .0005) and a lower aortic valve calcium score (p = .02) in the 4G‐BEV cohort at baseline. Age, STS risk score, NYHA Class, and aortic valve mean gradient did not differ between groups. 4G‐BEV was associated with a lower incidence of mild PVL (10.8 vs. 36.5%; p < .0001) and moderate PVL (0 vs. 5.8%) compared to the 3G‐BEV at 30 days. There was no association between PVL and valve size in either cohort.ConclusionsUtilization of 4G‐BEV is associated with reduced PVL at 30 days post‐TAVR compared with 3G‐BEV.
Transient Complete Heart Block After Alcohol Septal Ablation
Cha, Yong‐Mei , Klarich, Kyle W. , Rihal, Charanjit S. , Eleid, Mackram F. , El-Sabawi, Bassim, Bradley, David J. , El‐Sabawi, Bassim , Nishimura, Rick A. , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | August 6, 2020 | Volume: 13 | Issue: 8 | Pages: No page available

10.1161/circinterventions.120.009202 Get It

Acute fulminant hemolysis after transcatheter mitral valve replacement for mitral annular calcification
El‐Sabawi, Bassim , Eleid, Mackram F. , Rihal, Charanjit S. , Eleid, Mackram F , Guerrero, Mayra , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | May 6, 2020 | Volume: 96 | Issue: 3 | Pages: 706-711

10.1002/ccd.28944 Get It

AbstractTranscatheter mitral valve replacement (TMVR) is emerging as an alternative treatment strategy to surgery for patients with severe mitral annular calcification (MAC) who are not candidates for traditional mitral valve surgery. Paravalvular leak (PVL) is common following TMVR for severe MAC and can lead to heart failure symptoms and/or intravascular hemolysis, the latter of which usually is clinically stable. We report the case of a 67‐year‐old woman with symptomatic severe aortic stenosis and mitral stenosis with MAC in the setting of prior chest irradiation who was treated initially with transcatheter aortic valve replacement followed by TMVR at a later date (Sapien S3 system; Edwards Lifesciences). Immediately following TMVR, she developed acute profound hemolysis which manifested with hemoglobinuria, transfusion‐dependent anemia, and acute renal failure requiring renal replacement therapy. She was treated with post‐dilation balloon valvuloplasty after failed transcatheter PVL closure 10 days following TMVR with resulting improvement in the PVL. The hemolytic anemia resolved and renal function recovered without the need for continued hemodialysis 2 months later and stabilization of glomerular filtration rate at 6 months. This case highlights a potential severe complication of TMVR in MAC and suggests that improvement in hemolysis and late recovery of renal function may occur following treatment of PVL.
Response by El-Sabawi et al to Letter Regarding Article, “Temporal Occurrence of Arrhythmic Complications After Alcohol Septal Ablation”
El‐Sabawi, Bassim , Eleid, Mackram F. , Nishimura, Rick A.

Circulation: Cardiovascular Interventions | March 12, 2020 | Volume: 13 | Issue: 3 | Pages: No page available

10.1161/circinterventions.120.009059 Get It

Temporal Occurrence of Arrhythmic Complications After Alcohol Septal Ablation
El‐Sabawi, Bassim , Barsness, Gregory W. , Cha, Yong‐Mei , Geske, Jeffrey B. , Eleid, Mackram F. , Geske, Jeffrey B , Nishimura, Rick A.

Circulation: Cardiovascular Interventions | January 24, 2020 | Volume: 13 | Issue: 2 | Pages: No page available

10.1161/circinterventions.119.008540 Get It

Background: The temporal occurrence of arrhythmic complications after alcohol septal ablation (ASA) is unclear. As a result, the appropriate time to monitor patients after ASA is controversial. The purpose of this study is to determine the temporal occurrence of complete heart block (CHB) and ventricular tachyarrhythmia (VT) after ASA to better understand when patients can be safely discharged. Methods: Consecutive patients treated with ASA for hypertrophic cardiomyopathy from 2003 to 2019 at a tertiary referral center were reviewed retrospectively. The incidence and timing of CHB or sustained VT within 30 days post-ASA were assessed. Results: A total of 243 patients were included in this study. Mean maximal septal thickness was 19.0±3.9 mm, and total volume of ethanol injected was 1.7±0.6 mL. CHB occurred in 59 (24.3%) patients, including transient CHB in 33 (13.6%) and permanent in 26 (10.7%). The initial episode of CHB occurred within 24 hours post-ASA in 51 (21.0%) patients, between 24 and 48 hours in 3 (1.2%), between 48 and 72 hours in 3 (1.2%), and after 72 hours in 2 (0.8%). New permanent pacemaker was placed in 46 (18.3%). Presence of baseline bundle branch block and age ≥70 were significantly associated with CHB but not CHB presenting after 24 hours. VT occurred in 3 (1.2%) patients, including 1 (0.4%) within 24 hours, 1 (0.4%) between 24 and 48 hours, and 1 (0.4%) after 72 hours. VT required cardioversion in 2 patients and new implantable cardioverter-defibrillator placement in 2. Conclusions: The incidence of CHB or VT presenting after 72 hours post-ASA was low. These findings suggest that timely discharge of patients without evidence of early conduction disturbances after ASA can be considered as a potentially safe management strategy, especially in patients without preexisting conduction abnormalities.
Transcatheter closure of coronary artery fistula: A 21‐year experience
El‐Sabawi, Bassim , Al‐Hijji, Mohammed , Eleid, Mackram F. , Cabalka, Allison K. , Ammash, Naser M., Dearani, Joseph A. , Bjarnason, Haraldur , Holmes, David R. , Rihal, Charanjit S. , Al-Hijji, Mohammed A , Cabalka, Allison , Bjarnason, Haraldur , Dearani, Joseph A. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | January 10, 2020 | Volume: 96 | Issue: 2 | Pages: 311-319

10.1002/ccd.28721 Get It

AbstractObjectivesTo evaluate the outcomes of transcatheter coronary artery fistula (CAF) closure and to identify anatomic/procedural factors that may impact outcomes.BackgroundDue to the rarity of CAF, reported experience with transcatheter closure remains limited and anatomic and procedural factors that may lead to unsuccessful closure, complications, or recanalization of CAF are unclear.MethodsAll patients who underwent transcatheter CAF closure at Mayo Clinic from 1997 to 2018 were retrospectively reviewed. CAF anatomic characteristics, procedural techniques, and clinical/angiographic outcomes were assessed.ResultsA total of 45 patients underwent transcatheter closure of 56 CAFs. The most commonly used devices were embolization coils in 40 (71.4%) CAFs, vascular occluders in 10 (17.8%), or covered stent in 2 (3.6%). Acute procedural success with no or trivial residual flow occurred in 50 (89.3%) CAFs. Residual flow was small in three (5.4%) and large in three (5.4%). Eight (17.8%) patients had complications, including device migration in three, intracranial hemorrhage from anticoagulation in one, and myocardial infarction (MI) in four. MI was a result of covered stent thrombosis or stagnation of flow after closure of large distal CAF. Twenty‐two patients with 27 CAFs had follow‐up angiography after successful index procedure at median time of 423 (IQ 97‐1348) days. Of these, 23 (85.2%) had no/trace flow and 4 had large flow from recanalization.ConclusionsTranscatheter CAF closure is associated with a favorable acute procedural success and complication rate in selected patients. Procedural success and risk for complication are highly dependent on CAF anatomy and closure technique.