Back to Authors

Cabalka, Allison K.

https://orcid.org/0000-0003-3711-0003

Mayo Clinic

Mayo Clinic

Citations 48

Transcatheter Valve Replacement in Adults With Congenital Heart Disease—The Mayo Clinic Experience
Egbe, Alexander C. , Cabalka, Allison K. , Hagler, Donald J. , Eleid, Mackram F. , Rihal, Charanjit S. , Anderson, Jason H. , Taggart, Nathaniel W , Hagler, Donald J , Eleid, Mackram F , Rihal, Charanjit S. , Anderson, Jason , Cabalka, Allison , Taggart, Nathaniel W.

Circulation: Cardiovascular Interventions | October 27, 2025 | Volume: 18 | Issue: 12 | Pages: No page available

10.1161/circinterventions.125.015667 Get It

BACKGROUND: The current study aims to describe outcomes after transcatheter valve replacement in adults with congenital heart disease. METHODS: Retrospective study of adults with congenital heart disease who underwent transcatheter valve replacement and had a 1-year follow-up postintervention at Mayo Clinic (2010–2024). The study period was divided into early (2010–2014), mid (2015–2019), and late (2020–2024) eras. The primary outcome was valve reintervention. The secondary outcomes were all-cause mortality and temporal change in prosthetic valve gradient and clinical indices of disease severity. RESULTS: Overall, 341 patients (age 38±17 years; 175 [51%] men) received 346 prostheses (pulmonary [N=236, 68%], tricuspid [N=75, 22%], aortic [N=22, 8%], and mitral [N=7, 2%]). The prostheses were Sapien (N=181, 52%), Melody (N=142, 41%), and Harmony prostheses (N=23, 7%). The number of transcatheter valve implantations increased from the early era (N=75), mid era (N=109), to the late era (N=162). The 10-year incidence of valve reintervention was 35%, and was similar between Sapien versus Melody prosthesis (41% versus 33%; P =0.11). The 10-year incidence of all-cause mortality was 13%. There was a temporal increase in prosthetic valve Doppler mean gradient (baseline versus 10 years) for pulmonary (12±5 versus 28±11 mmHg; P <0.001), tricuspid (3±1 versus 8±3 mmHg; P <0.001), and aortic prosthesis (13±5 versus 26±12 mmHg; P <0.001). There was a temporal increase in predicted peak oxygen consumption (absolute ∆, 9% [95% CI, 4–13]; P =0.006) and a decrease in NT-proBNP (N-terminal pro-B-type natriuretic peptide) level (absolute ∆, −138 pg/mL [95% CI, −209 to −64]; P <0.001) at 1-year postintervention. CONCLUSIONS: There has been a temporal increase in the number of transcatheter valve implantations over time. Transcatheter valve replacement was associated with clinical improvement across multiple domains. However, there was a significant increase in prosthetic valve gradient within 10 years of follow-up, suggesting limited prosthesis longevity. There is a need for strategies to improve prosthetic valve longevity, which in turn may improve outcomes in this population.
Self‐Expanding Aortic Endoprosthesis for Conduit Preparation Prior to Transcatheter Pulmonary Valve Replacement
Krebushevski, Kaitlyn , Cabalka, Allison K. , Pollak, Peter , Yu, Liwei , Anderson, Jason H. , Pollak, Peter M , Cabalka, Allison , Anderson, Jason

Catheterization and Cardiovascular Interventions | July 30, 2025 | Volume: 106 | Issue: 4 | Pages: 2244-2251

10.1002/ccd.70039 Get It

ABSTRACT Background Preparation of the right ventricular outflow tract (RVOT) using covered stent placement is a common preparatory step for transcatheter pulmonary valve replacement (TPVR) to reduce the risk of disruption associated with dilating calcified RVOT conduits. Aim We present a novel method employing a self‐expanding covered aortic endoprosthesis and discuss its advantages as an alternative strategy. Methods Patients with congenital heart disease undergoing RVOT conduit preparation with the GORE TAG Thoracic Branch Endoprosthesis Extender (W.L. Gore & Associates, Newark, DE) followed by TPVR, were prospectively enrolled in a dedicated database. To date, 14 patients have been included. Data on demographics, diagnoses, procedural details, hemodynamic parameters, and outcomes were analyzed. Results Fourteen patients (median age: 35 years [range: 18–79]; 57% female) successfully underwent endograft placement immediately before TPVR. Treated conduits included pulmonary homografts ( n = 8), surgical bioprostheses ( n = 2), Hancock conduit ( n = 1), Contegra conduit ( n = 1), native RVOT ( n = 1), and Melody valve within a surgical bioprosthesis ( n = 1). Most patients presented with mixed stenosis and regurgitation ( n = 9), with the remaining having stenosis ( n = 4) or regurgitation ( n = 1). Valves implanted post‐preparation included the Sapien S3 valve (Edwards Lifesciences, Irvine, CA) ( n = 10) and the Melody valve (Medtronic, Minneapolis, MN) ( n = 5). Significant reductions in RVOT systolic gradient were observed (median 34 mmHg pre‐procedure to 3 mmHg post‐procedure), along with marked conduit expansion (median diameter 13 mm pre‐procedure to 25.5 mm post‐procedure). No complications were reported. Conclusions This study highlights the feasibility of a self‐expanding aortic endoprosthesis for RVOT preparation before TPVR. Further comparative study is warranted. Procedural success was achieved in all cases.
Midterm Outcomes in a Pooled Cohort of Harmony Transcatheter Pulmonary Valve Recipients
Morray, Brian H. , Gillespie, Matthew J. , Cheatham, John P. , Salavitabar, Arash , Peng, Lynn F., Jones, Thomas K. , Levi, Daniel S. , Gray, Robert G. , Asnes, Jeremy D. , Cabalka, Allison K. , Fujimoto, Kazuto , Qureshi, Athar M. , Bergersen, Lisa, Haugan, Daniel, McElhinney, Doff B. , Asnes, Jeremy D , Benson, Lee N. , McElhinney, Doff B , Jones, Thomas K , Morray, Brian H , Cabalka, Allison , Bergersen, Lisa

Circulation: Cardiovascular Interventions | July 16, 2025 | Volume: 18 | Issue: 9 | Pages: No page available

10.1161/circinterventions.125.015196 Get It

BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) is designed to treat severe pulmonary regurgitation in the native or surgically repaired right ventricular (RV) outflow tract. Early outcomes after TPV replacement with the Harmony valve have been positive, but longer-term data are limited. METHODS: The study included patients who received a commercially available TPV22 or TPV25 device as part of the nonrandomized, prospective Native Outflow Tract Early Feasibility Study, Harmony Pivotal Trial, and Continued Access Study. Patients completed at least 3 years of follow-up, and outcomes to 5 years were reported when available. RESULTS: Eighty-nine patients were catheterized, and 86 were successfully implanted with a Harmony TPV. Median duration of follow-up was 5 (range 0–6) years in the TPV22 group and 3 (1–4) years in the TPV25 group. At 3 years, all patients with a TPV22 and 96% of those with a TPV25 had ≤mild pulmonary regurgitation. By magnetic resonance imaging, significant improvements from preimplant to 2 years were observed in RV end-diastolic volume index, RV to left ventricular end-diastolic volume ratio, and effective RV stroke volume (all P <0.001). SF-36 quality-of-life scores improved after Harmony implantation and were sustained over 3 years. Early cases of ventricular tachycardia resolved, and there were no new arrhythmias. Adverse events up to 5 years included 3 deaths unrelated to the device or procedure, 2 cases of endocarditis that were treated (1 medically, 1 transcatheter debulking of a vegetation) and resolved, 6 patients with RV outflow tract obstruction or thrombosis resulting in valve-in valve procedures, and 1 major stent fracture resulting in surgical explant. CONCLUSIONS: At 3 to 5 years, Harmony TPV replacement resulted in sustained valve competence, beneficial cardiac remodeling, and improved quality of life. Continued monitoring is needed to assess long-term outcomes and valve performance. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01762124; NCT02979587.
Branched Endovascular Repair of Aortic Recoarctation and Postcoarctation Descending Thoracic Aortic Aneurysm With the Off-the-Shelf Thoracic Branch Endoprosthesis
Chait, Jesse , Varol, Muhammed , Mendes, Bernardo C. , Anderson, Jason H. , Cabalka, Allison K.

Journal of Endovascular Therapy | March 24, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15266028251328459 Get It

Recurrent coarctation of the aorta (reCoA) can be treated via redo surgical or endovascular means with the latter option providing a shorter hospitalization, expedient recovery, and a lower incidence of early morbidity and mortality. A common barrier to endovascular repair with standard thoracic endografts is the proximity of the left subclavian artery (LSA) to the reCoA which has previously necessitated adjunctive open revascularization or additional off-label endovascular techniques. This case describes percutaneous endovascular repair of postsurgical reCoA and a poststenotic descending thoracic aortic aneurysm with an off-the-shelf thoracic branched endograft incorporating the LSA with successful resolution of aortic pressure gradient and complete aneurysm exclusion. Clinical Impact This case highlights the use of a commercially available, off-the-shelf endograft to treat thoracic aortic coarctation and associated aortic aneurysm. The paper highlights unique technical points for use of the Gore Thoracic Branch Endoprosthesis in the off-label treatment of thoracic aortic coarctation which is an ideal endovascular option for lesions in proximity to the left subclavian artery.
Transcatheter Pulmonary Flow Restrictors as a Palliative Bridge to Heart Transplant
Masilamani, Mats Steffi Jennifer , Johnson, Jonathan N. , Ameduri, Rebecca , Stephens, Elizabeth H. , Cabalka, Allison K. , Anderson, Jason H. , Ameduri, Rebecca K , Cabalka, Allison , Anderson, Jason

Pediatric Transplantation | January 21, 2025 | Volume: 29 | Issue: 1 | Pages: No page available

10.1111/petr.70025 Get It

ABSTRACT Background In recent years, transcatheter implantation devices to restrict pulmonary arterial flow have emerged as a potential alternative to surgical pulmonary artery banding. Case Presentation A term male was diagnosed with critical aortic stenosis (AS) and severely reduced left ventricle (LV) systolic function. He underwent aortic balloon valvuloplasty on day 2 of life, resulting in some antegrade flow, but LV ejection fraction only improved to 15%. He remained ductal dependent for systemic perfusion. Pulmonary over‐circulation ensued with systemic steal evident in his second week of life. On day 14, he underwent a transcatheter stage 1 procedure including the placement of bilateral pulmonary flow restrictor (PFR) devices and ductal stenting. Post‐procedure, he improved clinically, weaned off respiratory support, and transitioned to oral feeds while awaiting cardiac transplant. Twelve days later, he received a donor heart, with an uneventful recovery. He is now 3 years post‐transplant and has excellent graft function, and his transplant course has been unremarkable. Conclusion Transcatheter‐based palliation for a neonate with critical AS, utilizing endoluminal PFRs, proved effective in stabilizing the infant and successfully bridging him to transplant. This highlights an opportunity for the utilization of PFRs in neonatal conditions where control of pulmonary blood flow is imperative as a bridge to transplantation.
Same‐Day Discharge After Uncomplicated Transcatheter Tricuspid Valve‐In‐Valve Implantation
Chan, Joseph , Anderson, Jason H. , Hagler, Donald J. , Chan, Joseph Mun Hoong , Cabalka, Allison K. , Taggart, Nathaniel W , Anderson, Jason , Taggart, Nathaniel W.

Catheterization and Cardiovascular Interventions | December 6, 2024 | Volume: 105 | Issue: 1 | Pages: 144-149

10.1002/ccd.31328 Get It

ABSTRACT Background Tricuspid valve‐in‐valve (TVIV) implantation has traditionally included post‐procedure overnight in‐hospital observation with next‐day discharge. Recently, our practice has shifted toward same‐day discharge for most patients after vascular access site hemostasis and adequate recovery from anesthesia. However, data on the safety of this approach remains scarce. Aims Our study aims to describe our practice change and to identify factors that may lead to overnight observation post‐TVIV. Methods We retrospectively reviewed medical records of patients who underwent uncomplicated TVIV implantation as an outpatient procedure at Mayo Clinic between 2011 and 2023. Results Of the 83 patients who underwent TVIV from 2011 to 2023, 65 (78%) were included in the study. The first 39 patients in our institutional series were observed overnight as standard practice. 18 (69%) of the most recent 26 patients in our series were discharged the same day; three patients who remained in the hospital overnight were because of provider preference and/or patient preference without any specific medical concern. Of all 47 patients who were observed overnight, one patient was treated for fluid overload, one patient had non‐sustained ventricular tachycardia on telemetry that resulted in adjustment of antiarrhythmic therapy, two patients had continued bleeding from the access sites and was observed for another day. Among the two of them, one also developed atrial tachyarrhythmias requiring initiation of additional antiarrhythmic therapy. Out of 18 patients discharged the same day, one patient had an ED presentation within 24 h due to access site bleeding which was resolved promptly. There was no mortality or procedural‐related readmission. Conclusion Same‐day discharge may be considered for adult patients who have undergone uncomplicated TVIV with adequate hemostasis and recovery after anesthesia.
Feasibility of intentional bioprosthetic valve fracture in the tricuspid position
Hagel, Jonathon A. , Qureshi, Athar M. , Tanase, Daniel , Eicken, Andreas , Zampi, Jeffrey D. , Cabalka, Allison K. , Anderson, Jason H. , Shahanavaz, Shabana , Qureshi, Athar M , Tanase, Daniel , Zampi, Jeffrey D , Cabalka, Allison , Anderson, Jason , Lin, C. Huie

Catheterization and Cardiovascular Interventions | August 1, 2024 | Volume: 104 | Issue: 3 | Pages: 523-530

10.1002/ccd.31168 Get It

AbstractBackgroundTranscatheter tricuspid valve‐in‐valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture.AimsEvaluate the feasibility of transcatheter tricuspid ViV replacement with fracture of the underlying BPV ring.MethodsAn international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow‐up data were collected. Comparison was made to the pre‐ and post‐ViV replacement with fracture of the tricuspid valve frame conditions.ResultsTen patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3–5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption.ConclusionIntentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.
Abstract 9476: Atrial Septostomy in Patients with Pulmonary Arterial Hypertension
Fenstad, Eric R. , Le, Rachel J., McGoon, Michael D., Reeder, Guy S., Hagler, Donald J. , Cabalka, Allison K. , Kane, Garvan C. , Frantz, Robert P.

Circulation | April 23, 2024 | Volume: 124 | Issue: suppl_21 | Pages: No page available

10.1161/circ.124.suppl_21.a9476 Get It

Introduction: Creation of an atrial septal defect via atrial septostomy (AS) is a therapeutic option traditionally utilized for PAH in settings where medical therapy was unavailable. Its utility in the context of progressive disease despite medical therapy remains incompletely understood. Hypothesis: AS may be a useful option in patients with symptomatic PAH despite medical therapy and may improve functional class. Methods: Single center retrospective study of all adult PAH patients receiving AS at a tertiary PAH referral center. Results: Eleven atrial septostomy procedures were performed in 8 patients who were refractory to maximal medical management. All patients were WHO functional class III or IV and average patient age was 40 ± 13 years with a female predominance (89%). Mean RA pressure was 18 ± 4 mm Hg with cardiac index of 2.28 ± 0.82 L/min/m 2 prior to AS. Mean pulmonary artery pressure was 63 mm Hg with a pulmonary artery saturation of 48% and average systolic blood pressure of 97 mm Hg. Baseline NT-proBNP was 5573 ± 4589 pg/ml with a mean 6 minute walk distance (6MWD) of 311 ± 131 meters. Five of the 11 procedures resulted in functional class improvement. Functional class change did not relate to change in 6MWD or NT-pro BNP level. Three patients had repeat AS due to spontaneous narrowing of the original septostomy, with a mean duration of 220 ± 135 days between procedures. One patient died within 30 days of the procedure and another at day 88 while one patient received a heart/lung transplant at day 42 post AS. Mean follow up was 243 ± 183 days. The REVEAL risk scores ranged from 10 to 15, with predicted 1 year survival from pre-septostomy clinical data ranging from 22% to 80% (mean predicted survival of 57%). Actual transplant free survival at 1 year was 63%. Conclusions: Selected patients at high risk for 1 year mortality may receive symptomatic benefit from atrial septostomy. One year mortality remains high, and not significantly different from that predicted by the REVEAL score. Atrial septostomy may be a palliative treatment option for patients who are refractory to maximal medical therapy but further long term investigation is necessary.
Transcatheter Pulmonary Valve Replacement With the Harmony Valve in Patients Who Do Not Meet Recommended Oversizing Criteria on the Screening Perimeter Plot
McElhinney, Doff B. , Gillespie, Matthew J. , Cabalka, Allison K. , Morray, Brian H. , Balzer, David T. , Qureshi, Athar M. , Hoskoppal, Arvind , Cabalka, Allison , Morray, Brian H , Qureshi, Athar M , Hoskoppal, Arvind K , Goldstein, Bryan H , McElhinney, Doff B , Aboulhosn, Jamil , Goldstein, Bryan H.

Circulation: Cardiovascular Interventions | April 12, 2024 | Volume: 17 | Issue: 5 | Pages: No page available

10.1161/circinterventions.123.013889 Get It

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.
Cardiac Reverse Remodeling and Changes in Heart Failure Indices After Transcatheter Tricuspid Valve Replacement in Adults With Congenital Heart Disease
Salama, Abdalla A., Miranda, William R. , Connolly, Heidi M. , Jain, Charles, Cabalka, Allison K. , Egbe, Alexander C. , Abozied, Omar A, Anderson, Jason H. , Miranda, William R , Connolly, Heidi M , Cabalka, Allison , Egbe, Alexander C , Abozied, Omar

Circulation: Cardiovascular Interventions | November 9, 2023 | Volume: 17 | Issue: 1 | Pages: No page available

10.1161/circinterventions.123.013334 Get It

BACKGROUND: There are limited data about changes in cardiac function (cardiac reverse remodeling) and heart failure indices after transcatheter tricuspid valve-in-valve replacement (TT-VIVR). The purpose of this study was to evaluate cardiac reverse remodeling and temporal changes in heart failure indices after TT-VIVR in adults with congenital heart disease. METHODS: Retrospective cohort study of adults with congenital heart disease that underwent TT-VIVR and had >6 months of follow-up (January 1, 2011, to April 30, 2023). Echocardiographic indices of cardiac remodeling and heart failure indices (New York Heart Association class, NT-proBNP (N-terminal pro-brain natriuretic peptide), glomerular filtration rate, and model for end-stage liver disease excluding international normalized ratio score) were assessed preintervention and at 1-, 3-, and 5-year postintervention. RESULTS: Of 39 patients (age 39 [32–46] years), 14 (36%) and 25 (64%) received Melody valve and Sapien valve prosthesis, respectively. At 1-year post-TT-VIVR, there was a temporal improvement in right atrial reservoir strain (17±8% versus 22±8%, P <0.001), right atrial volume (81 [59–108] versus 63 [48–82] mL/m 2 , P <0.001), right atrial pressure (12±4% versus 6±4%, P <0.001), and right ventricular global longitudinal strain (−15±7% versus −20±7%, P <0.001). Similarly, there was a temporal improvement in NT-proBNP, glomerular filtration rate, model for end-stage liver disease excluding international normalized ratio score, and New York Heart Association class. The temporal improvements in heart failure indices and valve function were maintained at 3- and 5-year post-TT-VIVR. CONCLUSIONS: Considering the significant mortality risk associated with reoperations for tricuspid valve replacement, these data suggest favorable outcomes after TT-VIVR, and support TT-VIVR as a viable alternative to surgical tricuspid valve replacement, especially in high-risk patients.