Back to Authors

Qureshi, Athar M

0000-0001-5992-568X

Mayo Clinic

Lillie Frank Abercrombie Section of Cardiology, Texas Children's Hospital, Baylor College of Medicine, Houston, Texas, USA.

Citations 2

Feasibility of intentional bioprosthetic valve fracture in the tricuspid position
Hagel, Jonathon A. , Qureshi, Athar M. , Tanase, Daniel , Eicken, Andreas , Zampi, Jeffrey D. , Cabalka, Allison K. , Anderson, Jason H. , Shahanavaz, Shabana , Qureshi, Athar M , Tanase, Daniel , Zampi, Jeffrey D , Cabalka, Allison , Anderson, Jason , Lin, C. Huie

Catheterization and Cardiovascular Interventions | August 1, 2024 | Volume: 104 | Issue: 3 | Pages: 523-530

10.1002/ccd.31168 Get It

AbstractBackgroundTranscatheter tricuspid valve‐in‐valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture.AimsEvaluate the feasibility of transcatheter tricuspid ViV replacement with fracture of the underlying BPV ring.MethodsAn international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow‐up data were collected. Comparison was made to the pre‐ and post‐ViV replacement with fracture of the tricuspid valve frame conditions.ResultsTen patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3–5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption.ConclusionIntentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.
Transcatheter Pulmonary Valve Replacement With the Harmony Valve in Patients Who Do Not Meet Recommended Oversizing Criteria on the Screening Perimeter Plot
McElhinney, Doff B. , Gillespie, Matthew J. , Cabalka, Allison K. , Morray, Brian H. , Balzer, David T. , Qureshi, Athar M. , Hoskoppal, Arvind , Cabalka, Allison , Morray, Brian H , Qureshi, Athar M , Hoskoppal, Arvind K , Goldstein, Bryan H , McElhinney, Doff B , Aboulhosn, Jamil , Goldstein, Bryan H.

Circulation: Cardiovascular Interventions | April 12, 2024 | Volume: 17 | Issue: 5 | Pages: No page available

10.1161/circinterventions.123.013889 Get It

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.