Background: Heart failure (HF) is the leading cause of mortality in adults with congenital heart disease (CHD) after transcatheter pulmonary valve replacement (TPVR), likely due to preexisting myocardial dysfunction and suboptimal reverse remodeling. Left ventricular (LV) diastolic dysfunction, unmasked by an acute increase in preload post-TPVR, may elevate left-sided filling pressures and precipitate pulmonary edema. However, the prognostic implications of elevated left-sided filling pressures prior to TPVR are currently unknown. Objective: To evaluate the prognostic value of pre-TPVR pulmonary artery wedge pressure (PAWP) and the heart failure with preserved ejection fraction – Age, Body mass index (BMI), Atrial fibrillation (HFpEF-ABA) score in patients undergoing TPVR. Methods: Adults with congenital heart disease (CHD) undergoing TPVR were stratified by pre-implant PAWP (<15 vs ≥15 mmHg) and HFpEF-ABA score (low <25%, intermediate 25–75%, high >75%). The composite endpoint was all-cause mortality, heart transplantation, heart failure (HF) hospitalization, or sustained ventricular arrhythmia. Kaplan-Meier and Cox regression analyses assessed associations with clinical outcomes. Results: Out of 150 patients, 37 (24.7%) had PAWP ≥15 mmHg. Elevated PAWP was associated with older age (36 [31;53] vs. 26 [19; 37] years, p<0.01), BMI (27.9 [24.5; 35.1] vs. 24.2 [20.6; 29.7] kg/m 2 , p<0.01), and higher HFpEF-ABA score (42.8 [9.5;63.6] vs. 6.4 [2.5;18.1]%, p<0.001) compared to normal PAWP. Over a median follow-up of 38 [13; 83] months, 26 events (17.3%) occurred. Kaplan-Meier analysis demonstrated a significant difference in event-free survival based on pre-TPVR PAWP categories (log-rank p=0.002) and HFpEF-ABA score categories (log-rank p<0.001). Elevated PAWP was associated with adverse outcomes (hazard ratio [HR] 4.27, 95% CI 1.61–11.31, p=0.003) (Figure 1), but this was no longer significant after age adjustment. HFpEF-ABA ≥25% was associated with adverse outcomes (HR 10.6, 95% CI 3.8–30.0, p<0.001) (Figure 2), independent of N-terminal prohormone of brain natriuretic peptide levels and left ventricular ejection fraction. Conclusion: Albeit confounded by demographics, pre-TPVR PAWP correlated with adverse long-term outcomes, and patients with this hemodynamic profile may require closer post-procedural surveillance. HFpEF-ABA was independently associated with incident events, representing an inexpensive, novel prognostic tool in patients undergoing TPVR.
Transcatheter Valve Replacement in Adults With Congenital Heart Disease—The Mayo Clinic Experience
BACKGROUND: The current study aims to describe outcomes after transcatheter valve replacement in adults with congenital heart disease. METHODS: Retrospective study of adults with congenital heart disease who underwent transcatheter valve replacement and had a 1-year follow-up postintervention at Mayo Clinic (2010–2024). The study period was divided into early (2010–2014), mid (2015–2019), and late (2020–2024) eras. The primary outcome was valve reintervention. The secondary outcomes were all-cause mortality and temporal change in prosthetic valve gradient and clinical indices of disease severity. RESULTS: Overall, 341 patients (age 38±17 years; 175 [51%] men) received 346 prostheses (pulmonary [N=236, 68%], tricuspid [N=75, 22%], aortic [N=22, 8%], and mitral [N=7, 2%]). The prostheses were Sapien (N=181, 52%), Melody (N=142, 41%), and Harmony prostheses (N=23, 7%). The number of transcatheter valve implantations increased from the early era (N=75), mid era (N=109), to the late era (N=162). The 10-year incidence of valve reintervention was 35%, and was similar between Sapien versus Melody prosthesis (41% versus 33%; P =0.11). The 10-year incidence of all-cause mortality was 13%. There was a temporal increase in prosthetic valve Doppler mean gradient (baseline versus 10 years) for pulmonary (12±5 versus 28±11 mmHg; P <0.001), tricuspid (3±1 versus 8±3 mmHg; P <0.001), and aortic prosthesis (13±5 versus 26±12 mmHg; P <0.001). There was a temporal increase in predicted peak oxygen consumption (absolute ∆, 9% [95% CI, 4–13]; P =0.006) and a decrease in NT-proBNP (N-terminal pro-B-type natriuretic peptide) level (absolute ∆, −138 pg/mL [95% CI, −209 to −64]; P <0.001) at 1-year postintervention. CONCLUSIONS: There has been a temporal increase in the number of transcatheter valve implantations over time. Transcatheter valve replacement was associated with clinical improvement across multiple domains. However, there was a significant increase in prosthetic valve gradient within 10 years of follow-up, suggesting limited prosthesis longevity. There is a need for strategies to improve prosthetic valve longevity, which in turn may improve outcomes in this population.
Coronary anomalies, although rare, should be considered when young patients present with angina. Clinical suspicion and multi-modality imaging including coronary angiography and tomographic imaging should be pursued for symptomatic patients such as the one we are presenting with anomalous right coronary artery from the pulmonary artery. She was promptly referred for surgical intervention with re-implantation of the right coronary artery onto the aorta.
Self‐Expanding Aortic Endoprosthesis for Conduit Preparation Prior to Transcatheter Pulmonary Valve Replacement
ABSTRACT Background Preparation of the right ventricular outflow tract (RVOT) using covered stent placement is a common preparatory step for transcatheter pulmonary valve replacement (TPVR) to reduce the risk of disruption associated with dilating calcified RVOT conduits. Aim We present a novel method employing a self‐expanding covered aortic endoprosthesis and discuss its advantages as an alternative strategy. Methods Patients with congenital heart disease undergoing RVOT conduit preparation with the GORE TAG Thoracic Branch Endoprosthesis Extender (W.L. Gore & Associates, Newark, DE) followed by TPVR, were prospectively enrolled in a dedicated database. To date, 14 patients have been included. Data on demographics, diagnoses, procedural details, hemodynamic parameters, and outcomes were analyzed. Results Fourteen patients (median age: 35 years [range: 18–79]; 57% female) successfully underwent endograft placement immediately before TPVR. Treated conduits included pulmonary homografts ( n = 8), surgical bioprostheses ( n = 2), Hancock conduit ( n = 1), Contegra conduit ( n = 1), native RVOT ( n = 1), and Melody valve within a surgical bioprosthesis ( n = 1). Most patients presented with mixed stenosis and regurgitation ( n = 9), with the remaining having stenosis ( n = 4) or regurgitation ( n = 1). Valves implanted post‐preparation included the Sapien S3 valve (Edwards Lifesciences, Irvine, CA) ( n = 10) and the Melody valve (Medtronic, Minneapolis, MN) ( n = 5). Significant reductions in RVOT systolic gradient were observed (median 34 mmHg pre‐procedure to 3 mmHg post‐procedure), along with marked conduit expansion (median diameter 13 mm pre‐procedure to 25.5 mm post‐procedure). No complications were reported. Conclusions This study highlights the feasibility of a self‐expanding aortic endoprosthesis for RVOT preparation before TPVR. Further comparative study is warranted. Procedural success was achieved in all cases.
Branched Endovascular Repair of Aortic Recoarctation and Postcoarctation Descending Thoracic Aortic Aneurysm With the Off-the-Shelf Thoracic Branch Endoprosthesis
Recurrent coarctation of the aorta (reCoA) can be treated via redo surgical or endovascular means with the latter option providing a shorter hospitalization, expedient recovery, and a lower incidence of early morbidity and mortality. A common barrier to endovascular repair with standard thoracic endografts is the proximity of the left subclavian artery (LSA) to the reCoA which has previously necessitated adjunctive open revascularization or additional off-label endovascular techniques. This case describes percutaneous endovascular repair of postsurgical reCoA and a poststenotic descending thoracic aortic aneurysm with an off-the-shelf thoracic branched endograft incorporating the LSA with successful resolution of aortic pressure gradient and complete aneurysm exclusion. Clinical Impact This case highlights the use of a commercially available, off-the-shelf endograft to treat thoracic aortic coarctation and associated aortic aneurysm. The paper highlights unique technical points for use of the Gore Thoracic Branch Endoprosthesis in the off-label treatment of thoracic aortic coarctation which is an ideal endovascular option for lesions in proximity to the left subclavian artery.
Novel Diagnosis of Isolated Cardiac Erdheim–Chester Disease by Interatrial Biopsy Using Frozen Section Examination
Erdheim–Chester disease (ECD) is a rare non-Langerhans cell histiocytosis characterised by multiorgan pathological histiocytic infiltration. Cardiac involvement occurs in 40–75% of patients and increases mortality. A 55-year-old woman with chest pain and dyspnoea was found to have an interatrial septal mass and aortitis suspicious for ECD without other organ involvement. After two inadequate transcatheter interatrial biopsies were obtained using ultrasound guidance alone, diagnostic samples were successfully obtained using intraprocedural frozen section examination. The patient started genotype-targeted treatment with good response. Biopsy confirmation of ECD is required to guide treatment; however, cardiac biopsies are uncommonly performed when other organs are affected. Our unique case of isolated cardiovascular involvement highlights how frozen sectioning with multimodal intraprocedural imaging guidance can improve diagnostic yield of endomyocardial biopsies. It also highlights how diagnosis of rare conditions requires careful multidisciplinary evaluation of affected organs, procedural risk and diagnostic yield. The use of frozen sectioning can improve diagnostic yield of endomyocardial biopsies.
Transcatheter Pulmonary Flow Restrictors as a Palliative Bridge to Heart Transplant
ABSTRACT Background In recent years, transcatheter implantation devices to restrict pulmonary arterial flow have emerged as a potential alternative to surgical pulmonary artery banding. Case Presentation A term male was diagnosed with critical aortic stenosis (AS) and severely reduced left ventricle (LV) systolic function. He underwent aortic balloon valvuloplasty on day 2 of life, resulting in some antegrade flow, but LV ejection fraction only improved to 15%. He remained ductal dependent for systemic perfusion. Pulmonary over‐circulation ensued with systemic steal evident in his second week of life. On day 14, he underwent a transcatheter stage 1 procedure including the placement of bilateral pulmonary flow restrictor (PFR) devices and ductal stenting. Post‐procedure, he improved clinically, weaned off respiratory support, and transitioned to oral feeds while awaiting cardiac transplant. Twelve days later, he received a donor heart, with an uneventful recovery. He is now 3 years post‐transplant and has excellent graft function, and his transplant course has been unremarkable. Conclusion Transcatheter‐based palliation for a neonate with critical AS, utilizing endoluminal PFRs, proved effective in stabilizing the infant and successfully bridging him to transplant. This highlights an opportunity for the utilization of PFRs in neonatal conditions where control of pulmonary blood flow is imperative as a bridge to transplantation.
Same‐Day Discharge After Uncomplicated Transcatheter Tricuspid Valve‐In‐Valve Implantation
ABSTRACT Background Tricuspid valve‐in‐valve (TVIV) implantation has traditionally included post‐procedure overnight in‐hospital observation with next‐day discharge. Recently, our practice has shifted toward same‐day discharge for most patients after vascular access site hemostasis and adequate recovery from anesthesia. However, data on the safety of this approach remains scarce. Aims Our study aims to describe our practice change and to identify factors that may lead to overnight observation post‐TVIV. Methods We retrospectively reviewed medical records of patients who underwent uncomplicated TVIV implantation as an outpatient procedure at Mayo Clinic between 2011 and 2023. Results Of the 83 patients who underwent TVIV from 2011 to 2023, 65 (78%) were included in the study. The first 39 patients in our institutional series were observed overnight as standard practice. 18 (69%) of the most recent 26 patients in our series were discharged the same day; three patients who remained in the hospital overnight were because of provider preference and/or patient preference without any specific medical concern. Of all 47 patients who were observed overnight, one patient was treated for fluid overload, one patient had non‐sustained ventricular tachycardia on telemetry that resulted in adjustment of antiarrhythmic therapy, two patients had continued bleeding from the access sites and was observed for another day. Among the two of them, one also developed atrial tachyarrhythmias requiring initiation of additional antiarrhythmic therapy. Out of 18 patients discharged the same day, one patient had an ED presentation within 24 h due to access site bleeding which was resolved promptly. There was no mortality or procedural‐related readmission. Conclusion Same‐day discharge may be considered for adult patients who have undergone uncomplicated TVIV with adequate hemostasis and recovery after anesthesia.
Detection of Right and Left Ventricular Dysfunction in Pediatric Patients Using Artificial Intelligence–Enabled ECGs
Background Early detection of left and right ventricular systolic dysfunction (LVSD and RVSD respectively) in children can lead to intervention to reduce morbidity and death. Existing artificial intelligence algorithms can identify LVSD and RVSD in adults using a 12‐lead ECG; however, its efficacy in children is uncertain. We aimed to develop novel artificial intelligence–enabled ECG algorithms for LVSD and RVSD detection in pediatric patients. Methods and Results We identified 10 142 unique pediatric patients (age≤18) with a 10‐second, 12‐lead surface ECG within 14 days of a transthoracic echocardiogram, performed between 2002 and 2022. LVSD was defined quantitatively by left ventricular ejection fraction (LVEF). RVSD was defined semiquantitatively. Novel pediatric models for LVEF ≤35% and LVEF <50% achieved excellent test areas under the curve of 0.93 (95% CI, 0.89–0.98) and 0.88 (95% CI, 0.83–0.94) respectively. The model to detect LVEF <50% had a sensitivity of 0.85, specificity of 0.80, positive predictive value of 0.095, and negative predictive value of 0.995. In comparison, the previously validated adult data‐derived model for LVEF <35% achieved an area under the curve of 0.87 (95% CI, 0.84–0.90) for LVEF ≤35% in children. A novel pediatric model for any RVSD detection reached a test area under the curve of 0.90 (0.87–0.94). Conclusions An artificial intelligence–enabled ECG demonstrates accurate detection of both LVSD and RVSD in pediatric patients. While adult‐trained models offer good performance, improvements are seen when training pediatric‐specific models.
Feasibility of intentional bioprosthetic valve fracture in the tricuspid position
AbstractBackgroundTranscatheter tricuspid valve‐in‐valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture.AimsEvaluate the feasibility of transcatheter tricuspid ViV replacement with fracture of the underlying BPV ring.MethodsAn international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow‐up data were collected. Comparison was made to the pre‐ and post‐ViV replacement with fracture of the tricuspid valve frame conditions.ResultsTen patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3–5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption.ConclusionIntentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.