BACKGROUND: Pulsed field ablation is now widely used for atrial fibrillation (AF) ablation, but atrial tachyarrhythmia recurrence remains common and postablation risk tools are limited. We assessed whether a validated sinus‑rhythm artificial intelligence— enabled ECG AF probability score, and its early postablation change, predicts recurrence after pulsed field ablation. METHODS: We studied consecutive patients undergoing index pulsed field ablation across 3 Mayo Clinic sites (February 2024–March 2025) with ≥1 sinus‑rhythm ECG within 180 days preprocedure. Baseline artificial intelligence—enabled ECG AF score (range 0–1) was the mean across baseline ECGs. Recovery indices (RI30/60/90), defined as mean postprocedure artificial intelligence—enabled ECG score within days 1–30/60/90 minus baseline, predicted post‑blanking recurrence using corresponding 30‑, 60‑, and 90‑day blanking windows. The primary outcome was time to first documented AF/atrial flutter/atrial tachycardia episode >30 seconds, ascertained via clinic ECGs, ambulatory monitoring, and device interrogations. Cox regression adjusted for prespecified clinical and echocardiographic covariates assessed associations; Harrell C‑statistic quantified discrimination. RESULTS: Among 1052 patients (67±10 years; 33% women), median baseline score was 0.35; 320 (30%) recurred over 188 days. Higher baseline score independently predicted recurrence (hazard ratio per 0.1 increase, 1.08 [95% CI, 1.03–1.14]). Scores rose on day 0 after ablation, then declined over subsequent weeks, with persistently higher, less‑improving trajectories among patients who recurred (time×recurrence interaction P <0.001). Day 0 score was not independently associated with recurrence after adjustment. Attenuated early recovery (higher recovery index) was independently associated with recurrence, most robustly for RI-90 (hazard ratio per 0.1 increase, 1.15 [95% CI, 1.07–1.24]), and improved discrimination beyond baseline and covariates (C‑statistic, 0.63–0.67; ΔC=0.04). Findings were consistent in a historical thermal ablation cohort. CONCLUSIONS: Baseline and early postablation dynamics of a sinus‑rhythm artificial intelligence—enabled ECG AF probability score are associated with pulsed field ablation recurrence and may aid multivariable risk stratification; prospective validation is warranted.
AI to the Rescue: Fighting Atrial Fibrillation With Code
Background Early detection of left and right ventricular systolic dysfunction (LVSD and RVSD respectively) in children can lead to intervention to reduce morbidity and death. Existing artificial intelligence algorithms can identify LVSD and RVSD in adults using a 12‐lead ECG; however, its efficacy in children is uncertain. We aimed to develop novel artificial intelligence–enabled ECG algorithms for LVSD and RVSD detection in pediatric patients. Methods and Results We identified 10 142 unique pediatric patients (age≤18) with a 10‐second, 12‐lead surface ECG within 14 days of a transthoracic echocardiogram, performed between 2002 and 2022. LVSD was defined quantitatively by left ventricular ejection fraction (LVEF). RVSD was defined semiquantitatively. Novel pediatric models for LVEF ≤35% and LVEF <50% achieved excellent test areas under the curve of 0.93 (95% CI, 0.89–0.98) and 0.88 (95% CI, 0.83–0.94) respectively. The model to detect LVEF <50% had a sensitivity of 0.85, specificity of 0.80, positive predictive value of 0.095, and negative predictive value of 0.995. In comparison, the previously validated adult data‐derived model for LVEF <35% achieved an area under the curve of 0.87 (95% CI, 0.84–0.90) for LVEF ≤35% in children. A novel pediatric model for any RVSD detection reached a test area under the curve of 0.90 (0.87–0.94). Conclusions An artificial intelligence–enabled ECG demonstrates accurate detection of both LVSD and RVSD in pediatric patients. While adult‐trained models offer good performance, improvements are seen when training pediatric‐specific models.
Unlocking the potential of artificial intelligence in electrocardiogram biometrics: age-related changes, anomaly detection, and data authenticity in mobile health platforms
Abstract Aims Mobile devices such as smartphones and watches can now record single-lead electrocardiograms (ECGs), making wearables a potential screening tool for cardiac and wellness monitoring outside of healthcare settings. Because friends and family often share their smart phones and devices, confirmation that a sample is from a given patient is important before it is added to the electronic health record. Methods and results We sought to determine whether the application of Siamese neural network would permit the diagnostic ECG sample to serve as both a medical test and biometric identifier. When using similarity scores to discriminate whether a pair of ECGs came from the same patient or different patients, inputs of single-lead and 12-lead medians produced an area under the curve of 0.94 and 0.97, respectively. Conclusion The similar performance of the single-lead and 12-lead configurations underscores the potential use of mobile devices to monitor cardiac health.