Ventricular Fibrillation Mapping in a Large-Animal Model Using Dual Mechanical Circulatory Support: Electroanatomic Substrate Preservation Without Ischemic Changes
Quelal, Karol , Tri, Jason , Haq, Ikram-Ul , Welle, Amalia, Niu, Hanxu, Behfar, Atta , Yalamuri, Suraj , Ward, Robert C. , Ezzeddine, Fatima M. , Tolkacheva, Elena G. , Tan, Nicholas Y. , Munoz, Freddy Del‐Carpio , Asirvatham, Samuel J. , DeSimone, Christopher V. , Quelal, Karol , Tri, Jason A , Haq, Ikram U , Ward, Robert C , Ezzeddine, Fatima , Tolkacheva, E G , Del-Carpio Munoz, Freddy , Asirvatham, Samuel J , Behfar, Atta , Welle, Amalia A., Yalamuri, Suraj

Circulation: Arrhythmia and Electrophysiology | September 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1161/circep.126.014954 Get It

BACKGROUND: Ventricular fibrillation (VF) remains a leading cause of sudden cardiac death with an incompletely characterized electrophysiological substrate. Traditional large-animal VF models are limited by hemodynamic collapse and myocardial ischemia. This study establishes a reproducible swine model using dual mechanical circulatory devices to enable high-density electroanatomic mapping under nonischemic conditions. METHODS: Five Yorkshire swine (55–65 kg) underwent sustained VF supported by venoarterial extracorporeal membrane oxygenation (2.5–3.0 L/min) and percutaneous left ventricular unloading (Impella CP, P-2–P-4). High-density electroanatomic mapping using CARTO 7 was performed at baseline and after defibrillation. Bipolar voltage was acquired from 7 predefined ventricular regions (21 measurements per animal per time point; n=210 paired observations). Unipolar voltage mapping and continuous surface ECG monitoring were used to assess acute ischemic injury. Systemic perfusion was maintained at systolic arterial pressure ≥80 mm Hg. Linear mixed-effects modeling was used to analyze voltage changes from pre-VF to post-VF. RESULTS: Sustained VF (10±1 minutes) was reproducibly induced and maintained with consistent hemodynamics (systolic arterial pressure, 90±5 mm Hg; extracorporeal membrane oxygenation flow, 2.5±0.5 L/min). All animals were successfully defibrillated. High-density mapping was feasible in all experiments (1000±300 points per chamber). Bipolar voltage showed no change from pre-VF (5.86±2.56 mV) to post-VF (6.53±2.22 mV; mean difference, 0.67 mV [95% CI, –0.31 to 1.65]; P =0.15). Both left ( P =0.17) and right ventricles ( P =0.08) demonstrated voltage preservation. Regional analysis showed no significant changes (all P >0.05); post-VF voltages remained above viability thresholds (>1.5 mV). Unipolar voltage maps recovered toward baseline, with no ECG injury pattern identified after defibrillation. CONCLUSIONS: Dual mechanical circulatory support with venoarterial extracorporeal membrane oxygenation and Impella CP enables reproducible, high-fidelity electroanatomic mapping and preserves myocardial substrate after sustained VF in a large-animal model. This platform overcomes key technical barriers in VF research, providing a nonischemic foundation for future mechanistic and translational studies.
Limited Clinical Utility of Artificial Intelligence-Enabled Electrocardiogram for Bicuspid Aortic Valve Detection: Uncovering Limitations for Specific Cardiac Phenotypes
Montoya-Hernández, Manuel A. , López-Jiménez, Francisco , Poterucha, Timothy J. , Liu, Kan, Medina-Inojosa, Jose R., Tsaban, Gal , Attia, Zachi, Enriquez‐Sarano, Maurice , Oh, Jae K., Asirvatham, Samuel J. , Friedman, Paul A., Niaz, Talha , Madhavan, Malini, Michelena, Héctor I. , Asirvatham, Samuel J , Lopez-Jimenez, Francisco , Enriquez-Sarano, Maurice , Hernandez, Manuel Alejandro Montoya , Poterucha, Timothy Joseph , Medina‐Inojosa, José R. , Attia, Zachi I. , Oh, Jae K. , Friedman, Paul A. , Madhavan, Malini

Journal of the Heart Valve Society | September 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/30494826261488198 Get It

Background Bicuspid aortic valve (BAV) is the most common congenital heart defect, associated with a lifetime morbidity burden exceeding 80% and an estimated 7% probability of transmission to first-degree relatives. Hence, echocardiographic screening of relatives is recommended. The aim of our study is to develop an artificial intelligence-enabled electrocardiogram (AI-ECG) model for the detection of BAV. Methods Between January 1, 1990, and June 30, 2023, the Mayo Clinic healthcare system database was searched for patients aged ≥18 years with echocardiograms performed for family history of BAV, abnormal auscultation, a BAV-related diagnosis, or to rule out the condition, and with an electrocardiogram (ECG) obtained within 6 months. Cases were patients with a confirmed BAV diagnosis, and controls were those with normal aortic valves. ECGs were randomly assigned into training (80%), internal validation (10%), and test (10%) groups. The AI-ECG model was built using Keras under TensorFlow. Results A total of 13,065 valid ECG–echocardiogram pairs were included (mean [SD] age, 58 [17] years; 44% women), with a median time of 1 day (interquartile range, 0–3 days) between studies. With a 45% BAV prevalence in the test group ( n = 1301), the area under the curve was 0.704, positive predictive value (PPV) 60.1%, and negative predictive value (NPV) 69.4%. At a prevalence of 7%, the NPV increased to 96.1%, but the PPV decreased to 12.2%. Conclusions In this retrospective cohort and using the current AI-ECG model, BAV detection showed modest diagnostic performance and limited standalone clinical utility, suggesting that ECG-only screening for BAV may require additional modalities or more refined phenotyping.
Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States
Fatunde, Olubadewa A. , Vemulapalli, Hema Srikanth , Rodriguez, Juan F. , Rodriguez-Riascos, Juan F , Vemulapalli, Hema S , Somappa, Aakash , Estrada-Vargas, Camilo A , Fatunde, Olubadewa A , Prajapati, Poojan , Vijayakumar, Keerthika , Kapa, Suraj , Nguyen, Duy, Asirvatham, Samuel J , McLeod, Christopher J , El Masry, Hicham , Deshmukh, Abhishek J , Kella, Danesh K , Killu, Ammar M , Mulpuru, Siva K , Sardana, Mayank , Scott, Luis R , Sugrue, Alan M, Srivathsan, Komandoor , Prasitlumkum, Narut , Rojas, Carlos, Prajapati, Poojan , Vijayakumar, Keerthika , Kapa, Suraj , Nguyen, Duy, Asirvatham, Samuel J. , Madhavan, Malini , McLeod, Christopher J. , Masry, Hicham El , Deshmukh, Abhishek , Kella, Danesh , Killu, Ammar M. , Mulpuru, Siva K. , Scott, Luis R. , Sugrue, Alan , Srivathsan, Komandoor

Journal of Cardiovascular Electrophysiology | September 15, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/jce.70503 Get It

ABSTRACT Background Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. Objective To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry. Methods This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter‐defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances. Results Twenty‐six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [ n = 1] and vascular complications [ n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre‐existing valve disease. After a median follow‐up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence‐free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction. Conclusion PFA for VA appears feasible and acutely effective, with a low rate of procedure‐related complications. While acute success was high, long‐term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy‐delivery strategies. Larger prospective studies are warranted.
Cardiac Resynchronization Therapy and Circulating Metabolomic Profile in Patients With Advanced Heart Failure
Qian, Zhiyong , Lee, Hon-Chi , Mulpuru, Siva K. , Vučković, Ivan , Deshmukh, Abhishek , DeSimone, Christopher V. , Asirvatham, Samuel J. , Wen, Songnan, Li, Chuanwei , Zhang, Song , Dasari, Surendra, Dzeja, Petras P. , Yu, Bing , Bailey, Kent R. , Chen, Horng H. , Cha, Yong‐Mei , Deshmukh, Abhishek J , Lanza, Ian R , Yu, Bing , Bailey, Kent R , Chen, Horng , Cha, Yong-Mei , Asirvatham, Samuel J , DeSimone, Christopher V , Vuckovic, Ivan , Zhang, Song , Dasari, Surendra, Lanza, Ian R.

Circulation: Heart Failure | September 10, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1161/circheartfailure.125.014148 Get It

BACKGROUND: It is unknown whether cardiac resynchronization therapy (CRT) improves systemic metabolomic profile by enhancing left ventricular function. The observational cohort study aimed to investigate the effect of CRT on left ventricular ejection fraction (LVEF) and circulating plasma metabolites in patients who had heart failure with reduced LVEF. METHODS: We prospectively screened patients with ischemic cardiomyopathy and nonischemic cardiomyopathy who received CRT with a defibrillator for LVEF ≤35% according to current guidelines. Clinical assessment included echocardiography and device interrogation. Blood samples for metabolomic analysis were collected before CRT and at 6-month follow-up. Plasma was subjected to gas chromatography-mass spectrometry and 1 H nuclear magnetic resonance-based metabolomic analysis. RESULTS: Totally 92 patients were enrolled, with a mean age of 67.3±11.3 years (37.0% female). LVEF was significantly improved from 28.9±7.6% at baseline to 36.0±11.3% at 6 months ( P <0.001) and to 40.1±12.6% at 12 months ( P <0.001). After CRT, 42 metabolite features were significantly decreased compared with the baseline. The ketone bodies, including 3-hydroxybutyrate ( P <0.001) and acetone ( P =0.01), were reduced. A branched-chain amino acid, isoleucine, was also decreased after CRT ( P =0.01). These metabolomic changes were mainly observed in the nonischemic cardiomyopathy group, while the metabolomic profile in the ischemic cardiomyopathy group was characterized by enhanced amino acid oxidation and elevated levels of lactate and pyruvate. The improvement in LVEF positively correlated with the ratio of changes in ketone bodies and isoleucine. CONCLUSIONS: CRT may modulate the systemic plasma metabolomic profile, which correlated with improvement in left ventricular function in patients with severe heart failure with reduced ejection fraction.
Incidence and Risk Factors of Mortality in Adults with Congenital Heart Disease: Results from the Mayo Adult Congenital Heart Disease Registry
Nallathambi, Naveenkumar , Gupta, Ishika, Vijayakumar, Keerthika , Miranda, William R. , Egbe, Alexander C. , Burchill, Luke J. , Lahr, Brian D. , Lee, Alexander T.J. , Deshmukh, Abhishek , Asirvatham, Samuel J. , Madhavan, Malini , Asirvatham, Samuel J , Burchill, Luke J , Gupta, Ishika

No container title available | August 10, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.08.07.26359991 Get It

Abstract Background Adults with congenital heart disease (ACHD) represent a rapidly expanding population with evolving mortality patterns. Despite improved survival, excess mortality persists. Objective To evaluate the incidence, causes, and predictors of mortality in a contemporary ACHD cohort. Methods We performed a retrospective cohort study of adults (≥18 years) first evaluated at Mayo Clinic from 2002–2023. Baseline clinical, imaging, and electrocardiographic data were analyzed. Vital status was determined using institutional records and the Accurint national mortality database. Kaplan-Meier analysis and Cox proportional hazard models were used to evaluate mortality and identify independent predictors of mortality Results A total of 7,678 ACHD patients were included, with median age of 36.8 years and median follow-up of 11.4 years. During 78,768 patient-years of follow-up, 1,116 patients died (median age at death 57.2 years), corresponding to an annual mortality rate of 1.4%. The cumulative rate of all-cause mortality at 5, 10, 15, and 20 years was 6.9%, 12.0%, 19.0%, and 26.2%, respectively. When stratified by CHD complexity, the annual death rate in patients with severe CHD (2.4%/year) was twice that of patients with moderate or mild CHD (both 1.2%/year). Older age and ACHD subtypes, specifically, cyanotic heart disease (HR 3.9, 95% CI 2.9–5.3) and Fontan physiology (HR 3.2, 95% CI 2.3–4.4), were strongly associated with increased mortality. Additional independent predictors included male sex, ventricular dysfunction, advanced NYHA class, prior heart failure hospitalization, hypertension, smoking, coronary artery disease, renal dysfunction, and abnormal hemoglobin levels. Cardiovascular causes accounted for 57.7% of deaths with known etiology, predominantly heart failure (48.9%) and sudden cardiac death (21.9%), while non-cardiovascular causes were driven mainly by infection and malignancy. Conclusions In this large contemporary ACHD cohort, mortality was driven by ventricular dysfunction, heart failure, and systemic end-organ involvement in addition to the underlying congenital anatomy. Both cardiovascular and non-cardiovascular causes contributed significantly to mortality. These findings underscore the need for comprehensive multidisciplinary ACHD care focused on early recognition of cardiac functional decline, management of acquired comorbidities, and end-organ dysfunction.
Empiric and Trigger‐Guided Superior Vena Cava Isolation in AF Ablation: Systematic Review and Meta‐Analysis
Sehrawat, Ojasav , Garg, Vasudha, Foo, Cher Y. , Khandekar, Ninad , Matai, Pallavi, ASIRVATHAM, SAMUEL, Siontis, Konstantinos C., Noseworthy, Peter A., Asirvatham, Samuel J. , Foo, Cher Ying , Asirvatham, Samuel J , Xue, Chao , Siontis, Konstantinos C. , Noseworthy, Peter A.

Pacing and Clinical Electrophysiology | May 19, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/pace.70296 Get It

ABSTRACT Background Superior vena cava isolation (SVCI) is performed as an adjunct to pulmonary vein isolation (PVI) for atrial fibrillation, yet whether an empiric or trigger‐guided strategy is preferable remains uncertain. Prior meta‐analyses have been largely restricted to index procedures in paroxysmal AF and have not explicitly stratified by ablation strategy. We sought to address these gaps through a systematic review of available randomized evidence. Methods Major databases were searched through November 2025 for RCTs comparing PVI+SVCI versus PVI alone. Trials were stratified by strategy: empiric SVCI (performed irrespective of SVC ectopy) or trigger‐guided SVCI (performed only upon demonstrated SVC triggers). The primary outcome was atrial tachyarrhythmia recurrence (≥30 s) beyond the blanking period. Random‐effects models, pre‐specified subgroup analyses, meta‐regression, and GRADE certainty assessment were performed. Results Eight RCTs ( n = 1231) were included; most enrolled paroxysmal AF, while two incorporated non‐paroxysmal AF subtypes and one evaluated repeat ablation procedures. Overall, SVCI+PVI significantly reduced recurrence versus PVI alone (97/604 vs. 135/627; RR 0.77, 95% CI 0.61–0.97; p = 0.03; I 2 = 0%). On stratified analysis, empiric SVCI demonstrated a significant recurrence reduction (RR 0.70, 95% CI 0.53–0.92; p = 0.01; I 2 = 0%), while trigger‐guided SVCI did not reach statistical significance (RR 0.80, 95% CI 0.37–1.74; p = 0.57; I 2 = 52%). In paroxysmal AF ( n = 1038), adjunctive SVCI significantly reduced recurrence compared with PVI alone (RR 0.68, 95% CI 0.52–0.90; p = 0.01; I 2 = 0%). Fluoroscopy time was longer with SVCI; total procedure duration was comparable. Major complications were infrequent but numerically higher with SVCI+PVI (15/604 vs. 7/627; RR 1.96, 95% CI 0.87–4.38; p = 0.10). Meta‐regression identified no significant effect modifiers. GRADE certainty was high for overall and empiric analyses, and moderate for trigger‐guided SVCI. Conclusions Empiric SVCI significantly reduced AT/AF recurrence as an adjunct to PVI, while trigger‐guided SVCI did not demonstrate a significant benefit. These findings suggest SVC isolation confers benefit independent of prior trigger documentation, supporting the role of empiric SVCI as an adjunct to AF ablation.
First-in-Human Clinical Experience With Focal Pulsed Field and Radiofrequency Dual-Modality Ablation for Treatment Refractory Left Ventricular Summit PVCs
Patil, Shivaraj, Liu, Xiaoke Ken, Siontis, Konstantinos C. , Prasitlumkum, Narut , Asirvatham, S, Cha, Yong‐Mei , Munoz, Freddy Del‐Carpio , Deshmukh, Abhishek , DeSimone, Christopher V. , Friedman, Paul A. , Madhavan, Malini , Mulpuru, S K, Munger, Thomas, Nguyen, Duy T. , Tan, N, Sugrue, Alan , Killu, Ammar M. , Asirvatham, Samuel J. , Liu, Xiaoke , Asirvatham, Samuel J , Del-Carpio Munoz, Freddy , Deshmukh, Abhishek J , Ezzeddine, Fatima , Friedman, Paul A , Kowlgi, Narayan G , Madhavan, Malini , Mulpuru, Siva K , Nguyen, Duy, Noseworthy, Peter A , Tan, Nicholas , Sugrue, Alan , Kapa, Suraj , Killu, Ammar M , DeSimone, Christopher V , Prasitlumkum, Narut , Ezzeddine, Fatima M. , Kowlgi, Gurukripa N. , Mulpuru, Siva K. , Munger, Thomas M., Noseworthy, Peter A. , Kapa, Suraj

Circulation: Arrhythmia and Electrophysiology | April 24, 2026 | Volume: 19 | Issue: 6 | Pages: No page available

10.1161/circep.126.014942 Get It

BACKGROUND: Radiofrequency (RF) ablation of premature ventricular complexes (PVCs) originating from the left ventricular summit may be unsuccessful, highlighting the need for alternative approaches. We aimed to assess the efficacy and safety of a novel dual-modality focal catheter in treating left ventricular summit PVCs in patients who had failed previous RF ablation. METHODS: Patients were prospectively enrolled and underwent a redo ablation procedure using an irrigated, contact-force sensing, dual-modality focal catheter (TactiFlex Duo, Abbott) under compassionate use indication. The ablation strategy, including the choice of energy modality (monopolar pulsed field [PF], RF, or both), was left to the operator’s discretion. Safety assessments included serial biomarkers, renal function, and CMR within 36 hours. Efficacy was defined as ≥80% reduction in PVC burden with symptom resolution at 3-month follow-up. RESULTS: Six consecutive patients (4 men; mean age, 53.8±15 years) with symptomatic left ventricular summit PVCs and a prior failed RF ablation (range, 1–2) were prospectively enrolled. All PVCs had an inferior axis, with a left bundle V1 morphology observed in 4 of 6 cases (mean burden, 30.1±5.3%). Acute suppression of PVCs was achieved in all cases. Acute suppression with a single PF application in the great cardiac vein-anterior interventricular vein occurred in 2 patients, while 3 patients required additional RF, PF, or combined RF+PF applications at adjacent sites. One patient with an inaccessible great cardiac vein-anterior interventricular vein was successfully treated in the left ventricular outflow tract with RF+PF application. Transient, reversible left anterior descending vasospasm was observed during PF delivery in 2 of 5 cases that underwent PF application adjacent to a coronary artery, despite pretreatment with intracoronary nitroglycerin without ECG or hemodynamic sequelae. All patients had durable suppression of PVCs at follow-up. CONCLUSIONS: In its first human application, dual-modality ablation was feasible and effective for refractory left ventricular summit PVCs. Transient coronary vasospasm occurred, though it was reversible and without acute clinical consequences.
Functional Evaluation of TRPC6 Missense Variants in Cancer Patients via Molecular Docking Analysis Compared with Patch Clamp Electrophysiology
Wu, Ying, SUN, XIAOJING , Reddy, Joseph S. , Advani, Pooja , Cerhan, J., Villarraga, Hector R, Asirvatham, Samuel J, Wang, R Y, Lee, H. C., Asirvatham, Samuel J. , Advani, Pooja P, Norton, Nadine , Asirvatham, Samuel J , Wu, Ying, Sun, Xiaojing, Boddicker, Nicholas , Cerhan, James R. , Villarraga, Hector R., Wang, Ru-Xing, Lee, Hon-Chi, Zanchi, Fernando Berton , Lu, Tong

No container title available | January 3, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.01.01.697223 Get It

ABSTRACT Gain-of-function mutations in the transient receptor potential 6 (TRPC6) channel have recently been recognized as risk factors for both doxorubicin (DOX)-induced cardiomyopathy. Functional evaluation of TRPC6 missense variants is therefore important for cancer patients undergoing anthracycline treatment. However, traditional electrophysiological methods are labor-intensive and time-consuming. In this study, we compared the functional responses of TRPC6 missense variants to 1-oleoyl-2-acetyl-sn-glycerol (OAG), a TRPC6 agonist, using molecular docking and patch clamp recording techniques. For the wild-type (WT) TRPC6 structure (PDB ID: 6UZ8), OAG exhibited a binding energy of -4.49 kcal/mol and a dissociation constant (Kd) of 0.511 mM. Twenty TRPC6 missense variants were identified from cancer patients in the Mayo Clinic database. Of these, fifteen variants had resolvable structures, nine of which displayed increased Kd values and six decreased Kd values compared to WT in molecular docking analysis. Patch clamp recordings revealed that TRPC6 WT and mutant channels were inactive at baseline but were activated upon 50 μM OAG stimulation, except two loss-of-function variants. Moreover, a 24-h treatment with 0.5 μM DOX significantly enhanced OAG-induced channel activation. All three variants identified in patients with heart failure demonstrated gain-of-function properties in both electrophysiological measurements and in-silico predictions. Importantly, the results obtained from molecular docking and patch clamp recordings were strongly correlated, showing an 82% concordance, higher than the predictions from AlphaMissense. These findings indicate that our computational analysis provides a rapid and reliable method for predicting the functional impact of TRPC6 missense variants, which may aid clinical decision-making in cancer patients receiving chemotherapy.
Dose-Dependent Effects of Radiation on the Coronary Arteries: Results From a Preclinical Model of Single-Fraction Proton Beam Cardiac Radioablation
Hirao, Tatsuhiko , Rettmann, Maryam E. , Deisher, A., Newman, Laura K. , Gades, Naomi M. , Lerman, Amir, Asirvatham, Samuel J., Kruse, Jon J. , Merrell, Kenneth W., Shumway, Dean A. , Packer, Douglas L. , Siontis, Konstantinos C., Lerman, Amir , Asirvatham, Samuel J. , Merrell, Kenneth W. , Deisher, Amanda J, Koya, Taro , Newman, Laura K , Gades, Naomi M , Lerman, Amir , Asirvatham, Samuel J , Kruse, Jon J , Merrell, Kenneth W , Shumway, Dean A , Packer, Douglas L , Siontis, Konstantinos C , Siontis, Konstantinos C.

Circulation: Arrhythmia and Electrophysiology | December 25, 2025 | Volume: 19 | Issue: 1 | Pages: No page available

10.1161/circep.125.013995 Get It

BACKGROUND: Cardiac radioablation is emerging as a treatment modality for refractory ventricular tachycardia. This study aimed to evaluate the effects of radiation on the coronary arteries in a swine model of proton beam cardiac radioablation. METHODS: Eighteen swine underwent single-fraction 30 to 40 Gy pencil-beam scanning proton therapy targeting the left ventricle and were euthanized 12 to 40 weeks later. Treatment planning was performed without restricting the dose to the coronary arteries. The maximum point dose (D max ) to the epicardial coronary arteries was calculated. In secondary analyses, the mean (D mean ) and minimum dose received by the highest irradiated 0.01 cm 3 (D 0.01 ) of each coronary artery were also calculated. Coronary artery segments were harvested from the D max sites for histological analysis, and the D max was correlated with stenosis severity. RESULTS: Ninety-six coronary arteries were analyzed. No stenoses were observed by computed tomography imaging preirradiation. By histological analysis posteuthanasia, 25/96 (26%) coronaries sampled at their D max sites had ≥75% stenosis. The median D max was 4.7 Gy for the <75% stenosis group and 29.7 Gy for the ≥75% stenosis group ( P <0.001). The AUC-ROC for the association between D max and stenosis ≥75% was 92.2%. A D max value of 20.1 Gy best predicted stenosis ≥75%, with sensitivity 92.3% and specificity 87.1%. The AUC-ROCs for the associations of D mean and D 0.01 with stenosis ≥75% were 84.8% and 91.6%, respectively. In histopathologic analysis, intimal hyperplasia was the most common coronary artery abnormality at the D max sites, and it was present in 61.5% of all arteries and in 93.9% of arteries with D max ≥20 Gy. CONCLUSIONS: In this preclinical model of proton beam cardiac radioablation, coronary stenoses occurred in a dose-dependent manner, with D max showing the closest correlation with stenosis ≥75%. These data provide for the first time a framework for dose constraint considerations for the coronary arteries during treatment planning for cardiac radioablation and thoracic malignancy radiation.
Local Calcium Chloride Infusion Enhances Acute and Chronic Efficacy of Ventricular Pulsed‐Field Ablation
Koya, Taro , Haq, Ikram ul, Tri, Jason , Yang, Ying, Otsuka, Naoto , Sauer, William H. , Asirvatham, S., Nguyen, Duy T., Asirvatham, Samuel J. , Sauer, William H. , Haq, Ikram U , Tri, Jason A , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | December 22, 2025 | Volume: 37 | Issue: 2 | Pages: 374-380

10.1111/jce.70228 Get It

ABSTRACT Background Pulsed‐field ablation (PFA) offers myocardial selectivity with minimal thermal injury, but depth for ventricular lesions may be insufficient or heterogeneous at clinically tolerable field strengths. Calcium electroporation—local calcium chloride (CaCl₂) infusion after PFA—may amplify electroporation‐mediated cell death while maintaining low energy settings. Objective To determine whether immediate post‐PFA CaCl₂ infusion enhances acute and chronic ventricular lesion formation in vivo. Methods Nine swine underwent focal ventricular PFA (750–1000 V, biphasic, 20 μs × 50 pulses, 200 ms interpulse) via an irrigated focal catheter and benchtop electroporator. Immediately post‐PFA, lesions were randomized to saline, 0.2 g Ca, or 0.4 g Ca infused locally through the catheter tip. Acute hearts were explanted for TTC analysis; surviving animals were studied at 7 days for chronic lesion geometry. Results Among 41 acute lesions (17 control, 12 Ca 0.2 g, 12 Ca 0.4 g), Ca 0.4 g increased dark‐zone depth (3.5 ± 1.4 vs. 2.3 ± 0.8 mm; p = 0.038) and pale‐zone depth (2.6 ± 1.3 vs. 1.3 ± 0.8 mm; p = 0.011) versus control. At 7 days ( n = 33 lesions), Ca 0.4 g produced larger scars than control (width 11.6 ± 2.1 vs. 10.0 ± 1.9 mm; p = 0.027; depth 4.2 ± 1 vs. 3.0 ± 0.8 mm; p < 0.001; volume 193.6.4 ± 82.3 vs. 109.4 ± 48.2 mm³; p = 0.001). Conclusions Local CaCl₂ infusion after ventricular PFA significantly augments acute electroporation effect and chronic lesion size at low output, supporting facilitated PFA as a strategy for deeper, more durable ventricular ablation.