Dose-Dependent Effects of Radiation on the Coronary Arteries: Results From a Preclinical Model of Single-Fraction Proton Beam Cardiac Radioablation
Hirao, Tatsuhiko , Rettmann, Maryam E. , Deisher, A., Newman, Laura K. , Gades, Naomi M. , Lerman, Amir, Asirvatham, Samuel J., Kruse, Jon J. , Merrell, Kenneth W., Shumway, Dean A. , Packer, Douglas L. , Siontis, Konstantinos C., Lerman, Amir , Asirvatham, Samuel J. , Merrell, Kenneth W. , Deisher, Amanda J, Koya, Taro , Newman, Laura K , Gades, Naomi M , Lerman, Amir , Asirvatham, Samuel J , Kruse, Jon J , Merrell, Kenneth W , Shumway, Dean A , Packer, Douglas L , Siontis, Konstantinos C , Siontis, Konstantinos C.

Circulation: Arrhythmia and Electrophysiology | December 25, 2025 | Volume: 19 | Issue: 1 | Pages: No page available

10.1161/circep.125.013995 Get It

BACKGROUND: Cardiac radioablation is emerging as a treatment modality for refractory ventricular tachycardia. This study aimed to evaluate the effects of radiation on the coronary arteries in a swine model of proton beam cardiac radioablation. METHODS: Eighteen swine underwent single-fraction 30 to 40 Gy pencil-beam scanning proton therapy targeting the left ventricle and were euthanized 12 to 40 weeks later. Treatment planning was performed without restricting the dose to the coronary arteries. The maximum point dose (D max ) to the epicardial coronary arteries was calculated. In secondary analyses, the mean (D mean ) and minimum dose received by the highest irradiated 0.01 cm 3 (D 0.01 ) of each coronary artery were also calculated. Coronary artery segments were harvested from the D max sites for histological analysis, and the D max was correlated with stenosis severity. RESULTS: Ninety-six coronary arteries were analyzed. No stenoses were observed by computed tomography imaging preirradiation. By histological analysis posteuthanasia, 25/96 (26%) coronaries sampled at their D max sites had ≥75% stenosis. The median D max was 4.7 Gy for the <75% stenosis group and 29.7 Gy for the ≥75% stenosis group ( P <0.001). The AUC-ROC for the association between D max and stenosis ≥75% was 92.2%. A D max value of 20.1 Gy best predicted stenosis ≥75%, with sensitivity 92.3% and specificity 87.1%. The AUC-ROCs for the associations of D mean and D 0.01 with stenosis ≥75% were 84.8% and 91.6%, respectively. In histopathologic analysis, intimal hyperplasia was the most common coronary artery abnormality at the D max sites, and it was present in 61.5% of all arteries and in 93.9% of arteries with D max ≥20 Gy. CONCLUSIONS: In this preclinical model of proton beam cardiac radioablation, coronary stenoses occurred in a dose-dependent manner, with D max showing the closest correlation with stenosis ≥75%. These data provide for the first time a framework for dose constraint considerations for the coronary arteries during treatment planning for cardiac radioablation and thoracic malignancy radiation.
Abstract 4357269: Dose-Dependent Effects of Radiation on the Coronary Arteries: Results from Proton Beam Cardiac Radioablation in Swine
Rettmann, Maryam E. , Deisher, A., Gades, Naomi M. , Kruse, Jon J. , Merrell, Kenneth W. , Shumway, Dean A. , Packer, D. L., Siontis, Konstantinos C. , Hirao, Tatsuhiko , Koya, Taro

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4357269 Get It

Background: Cardiac radioablation (CRA) is emerging as a treatment modality for refractory ventricular tachycardia (VT). This study aimed to evaluate the effects of radiation on the coronary arteries in a swine model of proton beam CRA. Methods: Eighteen domestic swine underwent 30–40 Gy pencil-beam scanning proton therapy in a single-fraction targeting the left ventricle with no attempt to spare coronary arteries and were euthanized 12-40 weeks later. Contrast-enhanced cardiac computed tomography (CT) was performed at baseline for treatment planning and at study end. Using dose-volume histograms, the maximum point (D max ), mean (D mean ) doses and the minimal doses received by the highest irradiated volumes of 0.01 cc (D 0.01cc ) for the left main, left anterior descending, circumflex, and right coronary artery, as well as the large diagonal and obtuse marginal branches were calculated. The D max location for each artery was mapped from the baseline planning CT onto the follow-up CT using deformable registration. Coronary artery segments were harvested from the D max sites for histological analysis. Receiver operating characteristic (ROC) analysis was performed to identify dose thresholds for predicting histologically severe coronary stenoses (≥75%). Results: Ninety-six coronary artery segments were analyzed. No stenoses were observed by CT imaging before irradiation. By histological analysis post-euthanasia, 25/96 (26%) coronary segments sampled at the Dmax site per artery had ≥75% stenosis. The median D max was 4.7 Gy for the <75% stenosis group and 29.7 Gy for the ≥75% stenosis group (p<0.001). The AUC-ROC for the association between D max and severe stenosis was 92.2%. A D max value of 20.1 Gy in a single fraction best predicted severe stenosis, with sensitivity of 92.3% and specificity of 87.1%. The AUC-ROC for the association between severe stenosis versus D mean and D 0.01cc was 84.8% and 91.6%, respectively. Based on histopathologic analysis, intimal hyperplasia was the most common coronary artery abnormality at the D max sites. Conclusion: In this pre-clinical model of proton beam CRA, coronary stenoses occurred in a dose-dependent manner, with D max being a better dosimetric predictor of stenosis than D mean and D 0.01cc . These data provide for the first time radiation dose constraint information for the epicardial coronary arteries that can be considered in treatment planning for CRA and radiation for thoracic malignancies.
Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model
Hirao, Tatsuhiko , Rettmann, Maryam E. , Schmidt, Megan , Yasin, Omar , Kowlgi, Gurukripa N. , Otsuka, Naoto , Koya, Taro , Newman, Laura K. , Packer, Douglas L. , Siontis, Konstantinos C. , Schmidt, Megan M , Yasin, Omar , Kowlgi, Narayan G

Circulation: Arrhythmia and Electrophysiology | January 24, 2025 | Volume: 18 | Issue: 2 | Pages: No page available

10.1161/circep.124.013120 Get It

BACKGROUND: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter. METHODS: Twenty canines were divided into 3 groups: 4 noninfarcted, acute (phase I); 8 noninfarcted, chronic (phase II); and 8 infarcted, chronic (phase III). Lesions were delivered with a temperature-controlled radiofrequency system utilizing a chemical vapor deposit diamond for efficient thermal diffusivity. In phase I, 17 ablation settings were tested (temperature set points, 50/60/70 °C; ablation duration, 15/30/60/90/120 s; and power limit, 30/50 W). Four and one of these sets of parameters were further tested in phases II and III, respectively. Lesions were assessed by ex vivo contrast-enhanced magnetic resonance imaging and gross pathology 5 weeks after ablation in phases II/III. RESULTS: Across all phases, 111 ablation lesions were delivered. Ablation with the power limit of 50 W, the temperature set point of 60 °C, and the duration of 60 s produced significantly larger and deeper lesions (mean, 569.2 mm 3 ; mean maximal depth, 9.8 mm) compared with 50 W/60 °C/30 s (mean, 340.4 mm 3 ; mean maximal depth, 8.3 mm) and 50 W/50 °C/60 s (mean, 227 mm 3 ; mean maximal depth, 6.9 mm), with P <0.05 for all pairwise comparisons. Ablation of infarcted myocardium in phase III (50 W/60 °C/30 s) resulted in smaller impedance and bipolar electrogram amplitude changes and lesion size compared with ablation in normal myocardium with the same settings. No steam pop, myocardial perforation, or char formation was observed in any of the 111 ablations across all phases. CONCLUSIONS: In vivo radiofrequency ablation in a canine model with a diamond-tip temperature-controlled catheter using a temperature set point of 60 °C and a power limit of 50 W created large lesions without steam pop risk in both normal and infarcted ventricular myocardia.
Abstract 4135873: Time Course of Late Gadolinium Enhancement Intensity in Ventricular Myocardium after Proton Beam Irradiation in Swine
Deisher, A., Newman, Laura K. , Kruse, Jon J. , Shumway, Dean A. , Merrell, Kenneth W. , Packer, D. L., Siontis, Konstantinos C. , Rettmann, Maryam E. , Koya, Taro , Hirao, Tatsuhiko

Circulation | November 13, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4135873 Get It

Background: Proton beam irradiation to the ventricular myocardium may enable non-invasive targeting of ventricular tachycardia. Previous work has demonstrated the feasibility of imaging ablation lesion with late gadolinium enhanced (LGE) cardiac magnetic resonance imaging (MRI). Hypothesis: We hypothesize that proton beam irradiation will lead to progressively increasing density of LGE corresponding to lesion formation during follow-up after treatment delivery. Aim: The aim of the current study was to determine the time course of LGE intensity in ventricular myocardium following proton beam therapy. Methods: Eleven swine were irradiated with 40 Gy proton beam in the anterior or lateral left ventricular (LV) followed by LGE cardiac MRI every 4 weeks for up to 24 weeks. After manual contouring of the endocardial and epicardial myocardium, a region of interest (ROI) in the area irradiated with 0-5 Gy was contoured (remote ROI). The mean and standard deviation (SD) of the signal intensity (SI) of the remote ROI were calculated. Light LGE was defined as voxels with SI > mean+2SD but < mean+3SD of the remote ROI, while voxels with SI > mean+3SD of the remote ROI were classified as having dense LGE. Voxels identified as bright due to image artifacts or noise were manually removed. The analysis was conducted in a fashion blinded to swine ID and time point after irradiation. Results: A total of 33 time points were analyzed (3.1 ± 1.4 MRI studies per swine). Figure 1A shows a representative time course of LGE in the same swine, progressing from diffuse light LGE at 8 weeks to dense LGE at 16-24 weeks. Figure 1B demonstrates the proportion of light versus dense LGE across timepoints in irradiated myocardial regions. At 8 weeks, light and dense LGE areas were evenly distributed. At 12 to 24 weeks, dense LGE increased to approximately 75%. The proportion of dense versus light LGE was significantly higher at 12, 16, and 24 weeks, as compared to 8 weeks. Conclusion: In ventricular myocardium, diffuse light LGE evident at 8 weeks progresses to denser LGE at 12-24 weeks following proton beam irradiation corresponding with lesion formation.
Abstract 11620: Time Course of Pericardial Effusion After Catheter-Free Ventricular Ablation With Proton Beam in Swine Normal Heart
Imamura, Kimitake, Suzuki, Atsushi , Yasin, Omar , Otsuka, Naoto , Packer, Douglas L. , Miller, Alexa, Hirao, Tatsuhiko , Rettmann, Maryam E. , Kowlgi, Gurukripa N. , Hohmann, Stephan , Konishi, Hiroki , Miller, Alexa

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.11620 Get It

Background: Cardiac proton beam ablation therapy has emerged as a promising tool for catheter-free arrhythmia ablation. The time course of the lesion change was demonstrated in MRI 8 weeks following the ablation; however, the pericardial effusion after the ablation has not been fully analyzed. Objective: The purpose of this study was to evaluate the pericardial effusion after pencil-beam scanned proton therapy on normal myocardium in swine in MRI. Methods: 32 domestic swine were irradiated with pencil-beam scanned proton therapy using irradiation doses of 30/40Gy to the left ventricle (LV) anterior wall, posterior wall, and apex. Each swine was subjected to monthly contrast-enhanced cardiac MRI to evaluate the post-irradiation effects. Results: Moderate to significant pericardial effusion (PE) was observed in 10 swine (31%), starting at 4 weeks, and increasing from 8-16 weeks until 24 weeks. With the exception of one case,, improvement was observed in all animals within a month from when the PE first became moderate or significant. . In the case where the significant PE did not improve, the PE was non-septic and transudate. Clinically, the PE did not cause cardiac tamponade and did not correlate to sudden death. Also, there was no correlation between animals with larger tissue volumes receiving higher dose (more than 20Gy) and the grade of PE . Conclusion: Proton beam radiation caused various grades of pericardial effusion, but in 90% of the animals, it resolved without intervention within a month with no major adverse events.