Ventricular Fibrillation Mapping in a Large-Animal Model Using Dual Mechanical Circulatory Support: Electroanatomic Substrate Preservation Without Ischemic Changes
Circulation: Arrhythmia and Electrophysiology | September 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available
BACKGROUND: Ventricular fibrillation (VF) remains a leading cause of sudden cardiac death with an incompletely characterized electrophysiological substrate. Traditional large-animal VF models are limited by hemodynamic collapse and myocardial ischemia. This study establishes a reproducible swine model using dual mechanical circulatory devices to enable high-density electroanatomic mapping under nonischemic conditions. METHODS: Five Yorkshire swine (55–65 kg) underwent sustained VF supported by venoarterial extracorporeal membrane oxygenation (2.5–3.0 L/min) and percutaneous left ventricular unloading (Impella CP, P-2–P-4). High-density electroanatomic mapping using CARTO 7 was performed at baseline and after defibrillation. Bipolar voltage was acquired from 7 predefined ventricular regions (21 measurements per animal per time point; n=210 paired observations). Unipolar voltage mapping and continuous surface ECG monitoring were used to assess acute ischemic injury. Systemic perfusion was maintained at systolic arterial pressure ≥80 mm Hg. Linear mixed-effects modeling was used to analyze voltage changes from pre-VF to post-VF. RESULTS: Sustained VF (10±1 minutes) was reproducibly induced and maintained with consistent hemodynamics (systolic arterial pressure, 90±5 mm Hg; extracorporeal membrane oxygenation flow, 2.5±0.5 L/min). All animals were successfully defibrillated. High-density mapping was feasible in all experiments (1000±300 points per chamber). Bipolar voltage showed no change from pre-VF (5.86±2.56 mV) to post-VF (6.53±2.22 mV; mean difference, 0.67 mV [95% CI, –0.31 to 1.65]; P =0.15). Both left ( P =0.17) and right ventricles ( P =0.08) demonstrated voltage preservation. Regional analysis showed no significant changes (all P >0.05); post-VF voltages remained above viability thresholds (>1.5 mV). Unipolar voltage maps recovered toward baseline, with no ECG injury pattern identified after defibrillation. CONCLUSIONS: Dual mechanical circulatory support with venoarterial extracorporeal membrane oxygenation and Impella CP enables reproducible, high-fidelity electroanatomic mapping and preserves myocardial substrate after sustained VF in a large-animal model. This platform overcomes key technical barriers in VF research, providing a nonischemic foundation for future mechanistic and translational studies.
Acid–Base Status During Venoarterial Extracorporeal Membrane Oxygenator Support in Patients With Cardiogenic Shock
Background The prognostic significance of an adverse acid–base milieu despite venoarterial extracorporeal membrane oxygenation support in patients with cardiogenic shock remains poorly defined. We examined metabolic and respiratory disturbances in the ELSO (Extracorporeal Life Support Organization) Registry among patients who received venoarterial extracorporeal membrane oxygenation support for refractory cardiogenic shock. Methods Arterial blood gas acid–base values at 24 hours following venoarterial extracorporeal membrane oxygenation initiation were analyzed, with patients classified by pH, arterial partial pressure of carbon dioxide, and bicarbonate. Multivariable logistic regression and exploratory machine learning analyses were used to assess predictors of in‐hospital mortality. Results Among 15 144 adult patients, 74.6% (10 860) had neither respiratory nor metabolic acidosis, 13.1% (1909) had isolated respiratory acidosis, 11.6% (1684) had isolated metabolic acidosis, and 0.7% (100) had combined acidosis. In‐hospital mortality occurred in 7719 (51.0%) patients and increased incrementally across patients with lower pH (adjusted odds ratio [OR], 2.03 with each 0.1‐unit decrease in pH, using 7.4 as a reference point [95% CI, 1.82–2.26]), bicarbonate (adjusted OR, 1.93 per each 5‐mEq/L <24 mEq/L [95% CI, 1.76–2.12]) or base excess (adjusted OR, 1.90 per each 5‐mEq/L <0 mEq/L [95% CI, 1.75–2.07]) (all P <0.01). Mortality varied significantly, being highest for the low‐pH metabolic acidosis cluster (adjusted OR, 1.90 [95% CI, 1.70–2.12], P <0.01). Conclusions Survival decreased progressively with worse acidemia or metabolic acidosis despite 24 hours of hemodynamic support with venoarterial extracorporeal membrane oxygenation among patients with cardiogenic shock. Our findings emphasize the prognostic significance of metabolic parameters as potentially modifiable risk factors and underscore the need for early recognition and interventions to mitigate severe metabolic derangements.
Atrial fibrillation and flutter conversion with pulsed electric field delivery: preclinical proof of concept
Abstract Background Many patients with atrial fibrillation (AF) suffer life-limiting symptoms and heart failure. Although enormous advances in rhythm control have been made, device-based therapies for treating recurrent episodes are limited. Using pulsed electric fields (PEF) to induce reversible electroporation of cardiac tissue may effectively terminate AF. Purpose To assess the feasibility of PEF delivery for converting atrial arrhythmias via reversible electroporation. Methods Four swine models were used in this acute study. Custom-made decapolar catheters for PEF delivery were deployed with the following configurations: 1. Endocardial right atrium (RA) and coronary sinus (CS), n=2; 2. Endocardial RA and epicardial left atrium (epiLA), n=2. AF and atrial flutter (AFL) were induced with programmed stimulation. PEF delivery was performed using the BTX 830 generator. For each attempt, a single monophasic pulse at 10 or 20µs pulse width was administered, with voltage varied across attempts (range 750-3000V). Successful (type 1 and 2 breaks) and unsuccessful conversion attempts were recorded. Post-PEF signal changes and arrhythmias were identified. Results A total of 58 AF/AFL (28 and 30 respectively) episodes were induced. Of the 37 successful conversion attempts, 33 (89.1%) were type 1 breaks. Conversion success probabilities generally increased with higher voltages for both configurations. >70% conversion success was seen with ≥1500V for the RA/CS configuration and ≥2000V for the RA/epiLA configuration. Arrhythmias including intra-atrial delay and high-grade atrioventricular block were seen, usually following successive PEF deliveries. Significant muscle stimulation was provoked with the current experimental setup. Conclusion Termination of atrial arrhythmias with PEF delivery is feasible, although further work is required to optimize its efficacy and safety.
Ventricular pulsed field defibrillation: preclinical feasibility study
Abstract Background Ventricular fibrillation (VF) is a leading cause of sudden cardiac death worldwide. Defibrillation via direct current shocks is effective but associated with significant pain and morbidity, prompting the need for alternative approaches. Reversible electroporation of cardiac tissue with pulsed electric fields (PEF) may be an effective means of terminating VF. Purpose To assess the feasibility of PEF delivery for terminating VF. Methods 5 acute swine models were used. Mechanical circulatory support with peripheral veno-arterial extracorporeal membrane oxygenation +/- percutaneous left ventricular assist device (Impella 5.5 L) was implemented and titrated to a mean arterial pressure ≥65 mmHg. Decapolar catheters were introduced into the endocardial right and/or left ventricle as well as epicardium. VF was induced with R on T shocks or rapid ventricular pacing. PEF was delivered with the endocardial catheter as the cathode and epicardial catheter as the anode; monophasic pulses (5-10) at 3000V, 100µs, and 200ms inter-pulse intervals were used. If VF persisted post-PEF, catheters were repositioned into regions of intact voltages for repeat delivery. Results 10 VF episodes were induced, 7 of which were successfully terminated with PEF delivery (70.0%). The median number of attempts to achieve VF termination was 2 (range 1-5). The post-VF rhythm was complete heart block with ventricular asystole in all successful defibrillation attempts, with no recovery after 30 minutes of observation. Significant muscle stimulation was seen with the utilized PEF parameters and catheter configurations. Conclusion Termination of VF using PEF – pulsed field defibrillation – is possible. However, further study is required to optimize delivery parameters/configurations to improve effectiveness and avoid muscle stimulation as well as conduction abnormalities.
Abstract 4363387: Porcine Model of Biventricular Pressure-Volume Loop Assessment during Impella 5.5 Support
Introduction: The Impella 5.5 is frequently employed to provide temporary mechanical circulatory support as bridge to recovery or durable therapy. Optimization of device management relies on understanding ventricular pressure-volume (PV) relationships. Aim: The aim of this study was to evaluate the biventricular (BiV) relationship with PV loop assessment during Impella 5.5 support in non-myopathic ventricles. Methods: Six domestic Yorkshire Pigs were used for this study. The Impella 5.5 (J&J MedTech, NJ) was inserted percutaneously under ultrasound and fluoroscopic guidance through either the carotid artery or aortic arch, using a 26Fr DrySeal Sheath (Gore, AZ). BiV PV loop conductance catheters (Sigma-M, CD Leycom, Hengelo, The Netherlands) were inserted via femoral venous access. The LV PV loop catheter is positioned via transeptal puncture and with intracardiac echocardiogram guidance. BiV PV loops are generated for each level of Impella 5.5 support. Results: With increasing levels of Impella 5.5 support, left ventricular (LV) PV loops shifted increasingly to the left and right ventricular (RV) loops to the right. Accordingly, LV end-diastolic volume (EDV) decreased (110±4 ml to 90±8 ml; p<0.001) and RV EDV increased (121±7 ml to 147±13 ml; p<0.001), from baseline to P9. Native LV systolic function decreased with increasing Impella 5.5 support, as demonstrated by a reduction in stroke volume (SV) (56±5 ml to 49±5 ml; p<0.001), cardiac output (CO) (3.4±0.8 ml/min to 2.0±0.3 ml/min; p<0.001), ejection fraction (EF) (51±4% to 44±6%; p<0.001), stroke work (SW) (4483±1023 ml*mmHg to 2383±719 ml*mmHg; p<0.001), and LV peak positive dP/dt (825 ± 184 mmHg/s to 523 ± 99 mmHg/s; p<0.001). Conversely, the native RV experienced preload-mediated increase in SV (65±7 ml to 86±20 ml; p<0.001), CO (3.7±0.8 ml/min to 4.3±0.9 ml/min; p<0.001), EF (53±4% to 58±11%; p<0.001), SW (918±143 ml*mmHg to 1529±365 ml*mmHg; p<0.001), and RV dP/dt (164±16 mmHg/s to 228±29 mmHg/s, p<0.001). Load independent contractility was assessed in the LV (1.64±0.33 mmHg/ml to 1.71±0.41 mmHg/ml; p=0.2) and RV (0.25±0.04 mmHg/ml to 0.29±0.05 mmHg/ml; p<0.001). Conclusions: This study highlights ventricular interdependence with Impella 5.5 support with opposing BiV trends. In a healthy heart, the RV can adequately compensate for increased preload offered by the device.
Abstract 4364029: Biventricular Pressure-Volume Loop Assessment of Impella 5.5 in a Porcine Model of Myocardial Infarction
Introduction: Microaxial flow pumps reduce mortality in myocardial infarction (MI) related cardiogenic shock (CS). The Impella 5.5 generates increased flow to provide circulatory support, and optimization relies on mechanistic understanding of pressure-volume (PV) relationships. Aim: Using a porcine model of acute MI in tandem with biventricular (BiV) PV loop conductance catheters, this study aimed to understand the impact of Impella 5.5 on BiV hemodynamics in MI CS. Methods: In 6 Domestic Yorkshire Pigs, an Impella 5.5 (J&J MedTech, NJ) was inserted percutaneously under fluoroscopic guidance via carotid or aortic access. An angioplasty balloon catheter was advanced past the first diagonal and inflated to above nominal pressure with blood flow obstruction for 90 minutes. BiV PV loop conductance catheters (Sigma-M, CD Leycom, Hengelo, The Netherlands) were inserted via femoral venous access. The left ventricle (LV) PV loop catheter is positioned via transeptal puncture using intracardiac echocardiography. BiV PV loops are generated for each level of Impella support from P1 to P7. Results: With increasing Impella 5.5 support, LV PV loops shifted to the left and right ventricular (RV) loops to the right. Without statistical significance, LV end diastolic volume (EDV) decreased by a mean of 12.3 ± 10.7% from baseline and RV EDV increased by 32 ± 40%. Native LV function decreased with increasing Impella 5.5 support, demonstrated by a reduction in stroke volume (SV) (35±13 ml to 27±14 ml; p<0.001), cardiac output (CO) derived from SV&heart rate (2.0±0.5 ml/min to 1.7±0.7 ml/min; p<0.001), and ejection fraction (EF) (37±7% to 29±12%; p<0.001). Less consistent trends were noted in peak positive dP/dt and end-systolic pressure volume relationship. Native RV function increased with higher levels of Impella 5.5 support, noted by increasing SV (27±24 ml to 41±28 ml; p=0.004), CO (1.6±1.2 ml/min to 2.3±1.4 ml/min; p=0.001), and EF (42±16% to 45±9%; p=0.04). Arterial elastance and ventriculo-arterial coupling increased in the LV from baseline to P7 (2.2±1.4 mmHg/ml to 2.8±1.0 mmHg/ml and 1.8±0.5 to 3.2±1.9, respectively; p<0.001) and decreased in the RV (1.3±0.7 mmHg/ml to 0.9±0.7 mmHg/ml (p<0.001) and 2.1±2.2 to 1.3±0.6 (p=0.004)). Conclusions: Impella 5.5 speed modulation highlights significant ventricular interdependence in the setting of acute MI. PV loop derived parameters here visualized parameters that may be utilized to improve optimization of hemodynamic support in CS.
Hyperoxia and End-Organ Complications Among Cardiogenic Shock Patients Supported by Venoarterial Extracorporeal Membrane Oxygenation
OBJECTIVES: To investigate whether severe hyperoxia predisposes to end-organ complications and whether these complications contribute to in-hospital mortality among cardiogenic shock (CS) patients supported in venoarterial extracorporeal membrane oxygenation (VA-ECMO). DESIGN: Adult patients with CS from the Extracorporeal Life Support Organization Registry between 2010 and 2023 were categorized into normoxia (Pao 2 60–150 mm Hg), mild hyperoxia (Pao 2 151–300 mm Hg), and severe hyperoxia (Pao 2 > 300 mm Hg) based on their Pao 2 at 24 hours. The primary outcome was in-hospital mortality. End-organ complications were analyzed using multivariate logistic regression models, and causal mediation analysis was performed to estimate the direct and indirect effects of hyperoxia on mortality. SETTING: Multicenter, multinational prospective cohort study. PATIENTS: Adults with CS supported on VA-ECMO. INTERVENTIONS: Partial pressure of oxygen at 24 hours after VA-ECMO cannulation. MEASUREMENTS/MAIN RESULTS: A total of 10,541 patients were included (normoxia: 48.4%, mild hyperoxia: 30.0%, severe hyperoxia: 21.5%). There was higher in-hospital mortality in patients with severe hyperoxia (71.7%, adjusted OR [aOR]: 2.17; 95% CI, 1.19–2.50) and mild hyperoxia (63.8%, aOR: 1.34; 95% CI, 1.19–1.50) compared normoxia (52.7%; referent group). Severe hyperoxia was associated with more end-organ complications, which incrementally predicted higher mortality (aOR: 1.42; 95% CI, 1.25–1.61). Mediation analysis demonstrated that hyperoxia primary exerted a direct effect on mortality (86%), with contributions from neurologic (3.1%), hepatic (3.9%), renal (3.5%), and bleeding (2.3%) complications. CONCLUSIONS: Severe hyperoxia in patients with CS receiving VA-ECMO is associated with increased mortality and more end-organ complications. However, most of the effect of severe hyperoxia on mortality occurs via direct effects, independent of end-organ complications. These findings highlight the potential direct toxicity of hyperoxia and underscore the need for strategies to optimize oxygen delivery in this critically ill population.
37: Empirically High-Dose Amphotericin B for Pulmonary Blastomycosis Requiring Venovenous Extracorporeal Membrane Oxygenation
The purpose of this study was to evaluate left ventricular (LV) unloading strategies in patients supported with peripheral venoarterial extracorporeal membrane oxygenation (VA-ECMO). A retrospective review was conducted of all consecutive patients requiring VA-ECMO support for any indication, who underwent novel LV unloading strategies with either direct left atrial venoarterial (LAVA) cannulation or pulmonary artery venoarterial (PAVA) venting, in comparison to Impella and intra-aortic balloon pump (IABP). The primary outcome was successful bridge to transplant, LV assist device, or myocardial recovery. Forty-six patients (63% male, mean age 52.8 ± 17.6 years) were included. Fourteen patients (30%) underwent novel unloading with either LAVA or PAVA, 11 patients (24%) underwent IABP placement, and 21 patients (46%) underwent Impella insertion. In the novel LV unloading cohort, 10 patients (71%) survived to hospital discharge. Four patients (29%) were weaned from ECMO and eight patients (57%) underwent cardiac transplantation. Although a trend favoring cannula-based unloading for the primary outcome was noted, the cohort was too small for statistical significance (79% LAVA/PAVA, 57% Impella, 45% IABP; p = 0.21). However, probability of survival was greater in the LAVA/PAVA cohort compared to Impella and IABP (p < 0.05). Thus, we demonstrate the efficacy of LA and PA cannulation as an alternative LV unloading strategy for patients supported with peripheral VA-ECMO.
Augmented Reality and Ultrasound-Guided Vascular Access