First-in-Human Clinical Experience With Focal Pulsed Field and Radiofrequency Dual-Modality Ablation for Treatment Refractory Left Ventricular Summit PVCs
Patil, Shivaraj, Liu, Xiaoke Ken, Siontis, Konstantinos C. , Prasitlumkum, Narut , Asirvatham, S, Cha, Yong‐Mei , Munoz, Freddy Del‐Carpio , Deshmukh, Abhishek , DeSimone, Christopher V. , Friedman, Paul A. , Madhavan, Malini , Mulpuru, S K, Munger, Thomas, Nguyen, Duy T. , Tan, N, Sugrue, Alan , Killu, Ammar M. , Asirvatham, Samuel J. , Liu, Xiaoke , Asirvatham, Samuel J , Del-Carpio Munoz, Freddy , Deshmukh, Abhishek J , Ezzeddine, Fatima , Friedman, Paul A , Kowlgi, Narayan G , Madhavan, Malini , Mulpuru, Siva K , Nguyen, Duy, Noseworthy, Peter A , Tan, Nicholas , Sugrue, Alan , Kapa, Suraj , Killu, Ammar M , DeSimone, Christopher V , Prasitlumkum, Narut , Ezzeddine, Fatima M. , Kowlgi, Gurukripa N. , Mulpuru, Siva K. , Munger, Thomas M., Noseworthy, Peter A. , Kapa, Suraj

Circulation: Arrhythmia and Electrophysiology | April 24, 2026 | Volume: 19 | Issue: 6 | Pages: No page available

10.1161/circep.126.014942 Get It

BACKGROUND: Radiofrequency (RF) ablation of premature ventricular complexes (PVCs) originating from the left ventricular summit may be unsuccessful, highlighting the need for alternative approaches. We aimed to assess the efficacy and safety of a novel dual-modality focal catheter in treating left ventricular summit PVCs in patients who had failed previous RF ablation. METHODS: Patients were prospectively enrolled and underwent a redo ablation procedure using an irrigated, contact-force sensing, dual-modality focal catheter (TactiFlex Duo, Abbott) under compassionate use indication. The ablation strategy, including the choice of energy modality (monopolar pulsed field [PF], RF, or both), was left to the operator’s discretion. Safety assessments included serial biomarkers, renal function, and CMR within 36 hours. Efficacy was defined as ≥80% reduction in PVC burden with symptom resolution at 3-month follow-up. RESULTS: Six consecutive patients (4 men; mean age, 53.8±15 years) with symptomatic left ventricular summit PVCs and a prior failed RF ablation (range, 1–2) were prospectively enrolled. All PVCs had an inferior axis, with a left bundle V1 morphology observed in 4 of 6 cases (mean burden, 30.1±5.3%). Acute suppression of PVCs was achieved in all cases. Acute suppression with a single PF application in the great cardiac vein-anterior interventricular vein occurred in 2 patients, while 3 patients required additional RF, PF, or combined RF+PF applications at adjacent sites. One patient with an inaccessible great cardiac vein-anterior interventricular vein was successfully treated in the left ventricular outflow tract with RF+PF application. Transient, reversible left anterior descending vasospasm was observed during PF delivery in 2 of 5 cases that underwent PF application adjacent to a coronary artery, despite pretreatment with intracoronary nitroglycerin without ECG or hemodynamic sequelae. All patients had durable suppression of PVCs at follow-up. CONCLUSIONS: In its first human application, dual-modality ablation was feasible and effective for refractory left ventricular summit PVCs. Transient coronary vasospasm occurred, though it was reversible and without acute clinical consequences.
Atrial fibrillation and flutter conversion with pulsed electric field delivery: preclinical proof of concept
Tan, N, Munoz, F Del-Carpio, Tri, Jason , Koya, T, Otsuka, Naoto , Desimone, C, Yalamuri, S, Maor, Elad, Miklavcic, D, Asirvatham, S, Munoz, Freddy Del‐Carpio , Koya, Taro , DeSimone, Christopher V. , Yalamuri, Suraj , Maor, Elad , Castellví, Quim , Ivorra, Antoni , Miklavčič, Damijan , Asirvatham, Samuel J.

European Heart Journal | February 4, 2026 | Volume: 46 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehaf784.786 Get It

Abstract Background Many patients with atrial fibrillation (AF) suffer life-limiting symptoms and heart failure. Although enormous advances in rhythm control have been made, device-based therapies for treating recurrent episodes are limited. Using pulsed electric fields (PEF) to induce reversible electroporation of cardiac tissue may effectively terminate AF. Purpose To assess the feasibility of PEF delivery for converting atrial arrhythmias via reversible electroporation. Methods Four swine models were used in this acute study. Custom-made decapolar catheters for PEF delivery were deployed with the following configurations: 1. Endocardial right atrium (RA) and coronary sinus (CS), n=2; 2. Endocardial RA and epicardial left atrium (epiLA), n=2. AF and atrial flutter (AFL) were induced with programmed stimulation. PEF delivery was performed using the BTX 830 generator. For each attempt, a single monophasic pulse at 10 or 20µs pulse width was administered, with voltage varied across attempts (range 750-3000V). Successful (type 1 and 2 breaks) and unsuccessful conversion attempts were recorded. Post-PEF signal changes and arrhythmias were identified. Results A total of 58 AF/AFL (28 and 30 respectively) episodes were induced. Of the 37 successful conversion attempts, 33 (89.1%) were type 1 breaks. Conversion success probabilities generally increased with higher voltages for both configurations. >70% conversion success was seen with ≥1500V for the RA/CS configuration and ≥2000V for the RA/epiLA configuration. Arrhythmias including intra-atrial delay and high-grade atrioventricular block were seen, usually following successive PEF deliveries. Significant muscle stimulation was provoked with the current experimental setup. Conclusion Termination of atrial arrhythmias with PEF delivery is feasible, although further work is required to optimize its efficacy and safety.
Ventricular pulsed field defibrillation: preclinical feasibility study
Tan, N, Munoz, F Del-Carpio, Tri, Jason , Koya, T, Otsuka, Naoto , Desimone, C, Yalamuri, S, Maor, Elad, Miklavcic, D, Asirvatham, S, Munoz, Freddy Del‐Carpio , Koya, Taro , DeSimone, Christopher V. , Yalamuri, Suraj , Maor, Elad , Castellví, Quim , Ivorra, Antoni , Miklavčič, Damijan , Asirvatham, Samuel J.

European Heart Journal | February 4, 2026 | Volume: 46 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehaf784.788 Get It

Abstract Background Ventricular fibrillation (VF) is a leading cause of sudden cardiac death worldwide. Defibrillation via direct current shocks is effective but associated with significant pain and morbidity, prompting the need for alternative approaches. Reversible electroporation of cardiac tissue with pulsed electric fields (PEF) may be an effective means of terminating VF. Purpose To assess the feasibility of PEF delivery for terminating VF. Methods 5 acute swine models were used. Mechanical circulatory support with peripheral veno-arterial extracorporeal membrane oxygenation +/- percutaneous left ventricular assist device (Impella 5.5 L) was implemented and titrated to a mean arterial pressure ≥65 mmHg. Decapolar catheters were introduced into the endocardial right and/or left ventricle as well as epicardium. VF was induced with R on T shocks or rapid ventricular pacing. PEF was delivered with the endocardial catheter as the cathode and epicardial catheter as the anode; monophasic pulses (5-10) at 3000V, 100µs, and 200ms inter-pulse intervals were used. If VF persisted post-PEF, catheters were repositioned into regions of intact voltages for repeat delivery. Results 10 VF episodes were induced, 7 of which were successfully terminated with PEF delivery (70.0%). The median number of attempts to achieve VF termination was 2 (range 1-5). The post-VF rhythm was complete heart block with ventricular asystole in all successful defibrillation attempts, with no recovery after 30 minutes of observation. Significant muscle stimulation was seen with the utilized PEF parameters and catheter configurations. Conclusion Termination of VF using PEF – pulsed field defibrillation – is possible. However, further study is required to optimize delivery parameters/configurations to improve effectiveness and avoid muscle stimulation as well as conduction abnormalities.