Back to Authors

Madhavan, Malini

0000-0002-2831-4568

Mayo Clinic

Mayo Clinic, Rochester, MN.

Citations 10

First-in-Human Clinical Experience With Focal Pulsed Field and Radiofrequency Dual-Modality Ablation for Treatment Refractory Left Ventricular Summit PVCs
Patil, Shivaraj, Liu, Xiaoke Ken, Siontis, Konstantinos C. , Prasitlumkum, Narut , Asirvatham, S, Cha, Yong‐Mei , Munoz, Freddy Del‐Carpio , Deshmukh, Abhishek , DeSimone, Christopher V. , Friedman, Paul A. , Madhavan, Malini , Mulpuru, S K, Munger, Thomas, Nguyen, Duy T. , Tan, N, Sugrue, Alan , Killu, Ammar M. , Asirvatham, Samuel J. , Liu, Xiaoke , Asirvatham, Samuel J , Del-Carpio Munoz, Freddy , Deshmukh, Abhishek J , Ezzeddine, Fatima , Friedman, Paul A , Kowlgi, Narayan G , Madhavan, Malini , Mulpuru, Siva K , Nguyen, Duy, Noseworthy, Peter A , Tan, Nicholas , Sugrue, Alan , Kapa, Suraj , Killu, Ammar M , DeSimone, Christopher V , Prasitlumkum, Narut , Ezzeddine, Fatima M. , Kowlgi, Gurukripa N. , Mulpuru, Siva K. , Munger, Thomas M., Noseworthy, Peter A. , Kapa, Suraj

Circulation: Arrhythmia and Electrophysiology | April 24, 2026 | Volume: 19 | Issue: 6 | Pages: No page available

10.1161/circep.126.014942 Get It

BACKGROUND: Radiofrequency (RF) ablation of premature ventricular complexes (PVCs) originating from the left ventricular summit may be unsuccessful, highlighting the need for alternative approaches. We aimed to assess the efficacy and safety of a novel dual-modality focal catheter in treating left ventricular summit PVCs in patients who had failed previous RF ablation. METHODS: Patients were prospectively enrolled and underwent a redo ablation procedure using an irrigated, contact-force sensing, dual-modality focal catheter (TactiFlex Duo, Abbott) under compassionate use indication. The ablation strategy, including the choice of energy modality (monopolar pulsed field [PF], RF, or both), was left to the operator’s discretion. Safety assessments included serial biomarkers, renal function, and CMR within 36 hours. Efficacy was defined as ≥80% reduction in PVC burden with symptom resolution at 3-month follow-up. RESULTS: Six consecutive patients (4 men; mean age, 53.8±15 years) with symptomatic left ventricular summit PVCs and a prior failed RF ablation (range, 1–2) were prospectively enrolled. All PVCs had an inferior axis, with a left bundle V1 morphology observed in 4 of 6 cases (mean burden, 30.1±5.3%). Acute suppression of PVCs was achieved in all cases. Acute suppression with a single PF application in the great cardiac vein-anterior interventricular vein occurred in 2 patients, while 3 patients required additional RF, PF, or combined RF+PF applications at adjacent sites. One patient with an inaccessible great cardiac vein-anterior interventricular vein was successfully treated in the left ventricular outflow tract with RF+PF application. Transient, reversible left anterior descending vasospasm was observed during PF delivery in 2 of 5 cases that underwent PF application adjacent to a coronary artery, despite pretreatment with intracoronary nitroglycerin without ECG or hemodynamic sequelae. All patients had durable suppression of PVCs at follow-up. CONCLUSIONS: In its first human application, dual-modality ablation was feasible and effective for refractory left ventricular summit PVCs. Transient coronary vasospasm occurred, though it was reversible and without acute clinical consequences.
Sociodemographic and Clinical Predictors of Mortality in Adults With Congenital Heart Disease
O'Sullivan, D, Samimi, Sahar , Anjewierdan, Scott , Wi, Chung‐Il, Lopez, Keila N. , Egbe, Alexander, Watson, Dave , Jain, C. Charlie, Juhn, Young J. , Miranda, William R. , Connolly, Heidi M., Madhavan, Malini, Burchill, Luke J., Wi, Chung‐Il , O’Sullivan, Donnchadh , O'Sullivan, Donnchadh , Wi, Chung-Ii , Egbe, Alexander C , Charles Jain, C , Connolly, Heidi M , Madhavan, Malini , Burchill, Luke J , Lopez, Keila N , Anjewierden, Scott , Jain, C. Charles , Connolly, Heidi M. , Madhavan, Malini , Burchill, Luke J.

Journal of the American Heart Association | March 25, 2026 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/jaha.125.045411 Get It

Background Mortality in adults with congenital heart disease (CHD) is strongly driven by disease complexity. Social determinants of health (SDOH) influence adult CHD (ACHD) health outcomes but their impact on mortality is unclear. This study examined the influence of clinical factors and SDOH on all‐cause mortality in patients with ACHD. Methods Single‐center retrospective cohort study of patients with ACHD in the Mayo ACHD Registry who had a verifiable residential address between January 1, 2004 and December 31, 2023. Clinical and SDOH indicators were extracted, including insurance type, language, rural–urban commuting area code, and a housing‐based socioeconomic index, an individual‐level measure of socioeconomic status derived from 4 objective housing characteristics and categorized into quartiles (Q1–Q4). Cox proportional‐hazards models were fitted to evaluate associations with mortality, incorporating CHD severity, arrhythmias, SDOH indicators, and other comorbidities. County of residence was included as a random effect, and model discrimination was assessed using the concordance statistic. Results Among 6134 patients with ACHD, the mean age was 38±16 years; 51% were male; 78.7% were White and 44.9% had rural residence. Independent predictors of mortality included cyanotic CHD (adjusted hazard ratio [aHR], 5.70 [95% CI, 2.90–11.23]), Fontan palliation (aHR, 4.98 [95% CI, 2.56–9.70]), ventricular tachycardia (aHR, 1.71 [95% CI, 1.16–2.52]), older age at first visit (aHR, 1.05 per year [95% CI, 1.04–1.05]), male sex (aHR, 1.19 [95% CI, 1.03–1.39]), public insurance (aHR, 1.60 [95% CI, 1.35–1.90]), rural residence (aHR, 1.25 [95%, CI 1.06–1.47]), and non‐English language (aHR 1.75 [95% CI 1.38–2.23]). The housing‐based socioeconomic index quartile was not associated with mortality. The final model achieved a concordance statistic of 0.77. Conclusions Mortality in patients with ACHD is strongly influenced by both clinical factors and SDOH, independent of socioeconomic status. Addressing barriers to care such as language, insurance, and geography is essential for improving ACHD survival particularly in those at increased mortality risk.
Outcomes in Patients With Mitral Annular Disjunction and an Implantable‐Cardioverter Defibrillator
Shin, Jee Won Jennifer, Siontis, Konstantinos C. , Killu, Ammar M. , Giudicessi, John R. , Ackerman, Michael J. , Deshmukh, Abhishek , Kowlgi, Gurukripa N. , Madhavan, Malini , McLeod, Christopher J., Asirvatham, Samuel J. , Munoz, Freddy Del‐Carpio , Shin, Jee Won , Ezzeddine, Fatima , Siontis, Konstantinos C , Killu, Ammar M , Giudicessi, J R , Ackerman, Michael J , Deshmukh, Abhishek J , Kowlgi, Narayan G , Madhavan, Malini , Asirvatham, Samuel J , Del-Carpio Munoz, Freddy , Ezzeddine, Fatima M. , Shin, Jee Won Jennifer, McLeod, Christopher J.

Journal of Cardiovascular Electrophysiology | March 18, 2025 | Volume: 36 | Issue: 5 | Pages: 1014-1021

10.1111/jce.16612 Get It

ABSTRACT Background Mitral annular disjunction (MAD) carries an increased risk of complex ventricular arrhythmias, which can lead to sudden cardiac death. Many of these patients undergo implantable cardioverter defibrillator (ICD) implantation, but their ICD outcomes are not known. Objective The aim of this study was to assess the outcomes of ICD implantation and the predictors of appropriate ICD therapies in patients with MAD. Methods The study included patients with MAD who underwent ICD implantation. Clinical, electrocardiographic, cardiac imaging, and device therapy data were collected. Results Forty‐nine patients with MAD and ICD were included. Median age was 49 (21) years, and 29 (59%) were female. 13 (27%) patients underwent ICD implantation for primary prevention and 36 (73%) patients for secondary prevention. Over a median follow‐up of 27.3 (35.3) months, 23 (47%) patients received ICD therapies. 18 (37%) patients had appropriate ICD therapies, and 5 (10%) patients had inappropriate ICD shocks. Median time to first appropriate therapy was 22.3 (63.3) months. In patients with a secondary prevention ICD indication, the rate of appropriate ICD therapies was 44%, while in patients with a primary prevention ICD indication, it was 15%. Among patients with appropriate ICD therapies, the first therapies were delivered for monomorphic ventricular tachycardia (VT) in 7 (39%) patients and polymorphic VT or ventricular fibrillation (VF) in 11 (61%) patients. Patients with appropriate ICD therapies were more likely to have a history of SCA ( p = 0.003) and/or low left ventricular ejection fraction (LVEF) ( p = 0.022) before ICD implantation as compared to patients without appropriate ICD therapies. Conclusions In our cohort of patients with MAD and ICD, appropriate ICD therapies were common. Most appropriate ICD therapies were delivered for polymorphic VT or VF. Larger studies are needed to elucidate the mechanisms of VAs and refine risk stratification in MAD.
Detection of Right and Left Ventricular Dysfunction in Pediatric Patients Using Artificial Intelligence–Enabled ECGs
Anjewierden, Scott , O’Sullivan, Donnchadh , Mangold, Kathryn, Greason, Grace , Attia, Zachi I. , López-Jiménez, Francisco , Friedman, Paul A. , Asirvatham, Samuel J. , Anderson, Jason H. , Eidem, Benjamin W., Johnson, Jonathan N. , Prakash, Shisheer Havangi, Madhavan, Malini , Mangold, Kathryn E , Attia, Zachi I , Anderson, Jason , Havangi Prakash, Shisheer, Niaz, Talha , Madhavan, Malini , Asirvatham, Samuel J , Lopez-Jimenez, Francisco , Niaz, Talha

Journal of the American Heart Association | November 4, 2024 | Volume: 13 | Issue: 21 | Pages: No page available

10.1161/jaha.124.035201 Get It

Background Early detection of left and right ventricular systolic dysfunction (LVSD and RVSD respectively) in children can lead to intervention to reduce morbidity and death. Existing artificial intelligence algorithms can identify LVSD and RVSD in adults using a 12‐lead ECG; however, its efficacy in children is uncertain. We aimed to develop novel artificial intelligence–enabled ECG algorithms for LVSD and RVSD detection in pediatric patients. Methods and Results We identified 10 142 unique pediatric patients (age≤18) with a 10‐second, 12‐lead surface ECG within 14 days of a transthoracic echocardiogram, performed between 2002 and 2022. LVSD was defined quantitatively by left ventricular ejection fraction (LVEF). RVSD was defined semiquantitatively. Novel pediatric models for LVEF ≤35% and LVEF <50% achieved excellent test areas under the curve of 0.93 (95% CI, 0.89–0.98) and 0.88 (95% CI, 0.83–0.94) respectively. The model to detect LVEF <50% had a sensitivity of 0.85, specificity of 0.80, positive predictive value of 0.095, and negative predictive value of 0.995. In comparison, the previously validated adult data‐derived model for LVEF <35% achieved an area under the curve of 0.87 (95% CI, 0.84–0.90) for LVEF ≤35% in children. A novel pediatric model for any RVSD detection reached a test area under the curve of 0.90 (0.87–0.94). Conclusions An artificial intelligence–enabled ECG demonstrates accurate detection of both LVSD and RVSD in pediatric patients. While adult‐trained models offer good performance, improvements are seen when training pediatric‐specific models.
Candidemia in Patients With Cardiovascular Implantable Electronic Devices: Uncertainty in Management Based on Current International Guidelines
Chesdachai, Supavit , Baddour, Larry M. , Palraj, Bharath Raj, Madhavan, Malini , Tabaja, Hussam , Fida, Madiha , DeSimone, Daniel C. , Palraj, Raj , Madhavan, Malini , Fida, Madiha , Challener, Douglas , DeSimone, Daniel C , Baddour, Larry , Palraj, Raj , Chesdachai, Supavit , Tabaja, Hussam , Sohail, M. Rizwan , Challener, Douglas W.

Open Forum Infectious Diseases | June 10, 2023 | Volume: 10 | Issue: 7 | Pages: No page available

10.1093/ofid/ofad318 Get It

Abstract Background In contrast to bloodstream infection due to a variety of bacteria in patients with cardiovascular implantable electronic devices (CIED), there are limited data regarding candidemia and risk of CIED infection. Methods All patients with candidemia and a CIED at Mayo Clinic Rochester between 2012 and 2019 were reviewed. Cardiovascular implantable electronic device infection was defined by (1) clinical signs of pocket site infection or (2) echocardiographic evidence of lead vegetations. Results A total of 23 patients with candidemia had underlying CIED; 9 (39.1%) cases were community onset. None of the patients had pocket site infection. The duration between CIED placement and candidemia was prolonged (median 3.5 years; interquartile range, 2.0–6.5). Only 7 (30.4%) patients underwent transesophageal echocardiography and 2 of 7 (28.6%) had lead masses. Only the 2 patients with lead masses underwent CIED extraction, but device cultures were negative for Candida species. Two (33.3%) of 6 other patients who were managed as candidemia without device infection subsequently developed relapsing candidemia. Cardiovascular implantable electronic device removal was done in both patients and device cultures grew Candida species. Although 17.4% of patients were ultimately confirmed to have CIED infection, CIED infection status was undefined in 52.2%. Overall, 17 (73.9%) patients died within 90 days of diagnosis of candidemia. Conclusions Although current international guidelines recommend CIED removal in patients with candidemia, the optimal management strategy remains undefined. This is problematic because candidemia alone is associated with increased morbidity and mortality as seen in this cohort. Moreover, inappropriate device removal or retention can both result in increased patient morbidity and mortality.
Cardiac Implantable Electronic Devices in Ebstein Anomaly: Management and Outcomes
Tan, Nicholas Y. , Amin, Mustapha, McLeod, Christopher J. , Stephens, Elizabeth H. , Cannon, Bryan C. , Miranda, William R. , Connolly, Heidi M. , Egbe, Alexander C. , Asirvatham, Samuel J. , Madhavan, Malini , McLeod, Christopher J , Stephens, Elizabeth H , Miranda, William R , Connolly, Heidi M , Egbe, Alexander C , Asirvatham, Samuel J , Madhavan, Malini , Dearani, Joseph A.

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010744 Get It

Background: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. Methods: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. Results: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P =0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. Conclusions: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.
Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery
Khalil, Fouad , Madhavan, Malini , Ahmad, Ali , Mulpuru, Siva K. , Siontis, Konstantinos C. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Siontis, Konstantinos C , Deshmukh, Abhishek J , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Khalil, Fouad , Toya, Takumi , Badawy, Mohamed, Kapa, Suraj , DeSimone, Christopher V.

Journal of Cardiovascular Electrophysiology | December 15, 2021 | Volume: 33 | Issue: 2 | Pages: 274-283

10.1111/jce.15331 Get It

AbstractBackgroundData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves.ObjectiveTo investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri‐operative complications, and outcomes.ResultsIn our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans‐septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar‐related reentry was the dominant mechanism of VT. Forty‐seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri‐mitral area in six patients with VT and five patients with PVC ablation. No procedure‐related complications were reported. The overall recurrence‐free rate at 1‐year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with MVS.
Device‐detected nonsustained ventricular tachycardia in adult congenital heart disease without tetralogy of fallot
Doctor, Pezad , Aggarwal, Sanjeev, Lawrence, David , Singh, Gautam K. , Madhavan, Malini , Sriram, Chenni S. , Madhavan, Malini , Sriram, Chenni S , Gupta, Pooja

Pacing and Clinical Electrophysiology | December 1, 2021 | Volume: 45 | Issue: 3 | Pages: 302-313

10.1111/pace.14420 Get It

AbstractObjectivesTo evaluate any association between non‐sustained ventricular tachycardia (NSVT) detected by intra‐cardiac device and clinical outcomes in repaired adult congenital heart disease (ACHD) without tetralogy of Fallot (TOF).BackgroundNSVT portends a higher risk of serious ventricular tachyarrhythmia in TOF. However its clinical significance when incidentally detected by implantable cardiac device is not well elucidated in non‐TOF ACHD cohort.MethodsWe performed a single center, retrospective, longitudinal follow‐up study in repaired ACHD (≥18 years) patients without TOF who hosted a pacemaker or automatic implantable cardiac defibrillator (AICD). The cohort was divided based on presence/absence of device detected NSVT. The primary end‐point was a composite of sustained ventricular tachycardia (VT), ventricular fibrillation (VF), or sudden cardiac death (SCD).ResultsOne hundred fifty eight patients (male 56.3%, median [IQR] age of 35 [28–43] years at last follow‐up] with longitudinal post‐implant follow‐up duration of 8 (5–12) years were included. NSVT was detected in 52 (33%) patients. The primary composite end‐point was more frequent in NSVT group [11.5% vs. 2.8%; p = .04]. Patients with NSVT were (i) older at the time of initial implant (age 25 vs. 18 years, p = .011) and more frequently demonstrated (ii) systemic ventricular dysfunction (44% vs. 26%; p = .015), as well as (iii) history of ventriculotomy (38% vs. 21%; p = .017).ConclusionsIn our repaired ACHD cohort, we noted a significant association between device‐detected‐NSVT and the primary composite end‐point of sustained VT/VF or SCD. Systemic ventricular dysfunction and history of ventriculotomy were more frequent in the NSVT group and likely constituted the clinical milieu.
Catheter ablation of ventricular tachycardia in patients with postinfarction left ventricular aneurysm
Amin, Mustapha, Hilaire, Emilie, Siontis, Konstantinos C. , Madhavan, Malini , Mulpuru, Siva K. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Farwati, Medhat , Siontis, Konstantinos C , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Deshmukh, Abhishek J , Cha, Yong-Mei , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Kapa, Suraj

Journal of Cardiovascular Electrophysiology | October 20, 2021 | Volume: 32 | Issue: 12 | Pages: 3156-3164

10.1111/jce.15273 Get It

AbstractBackgroundWhile ventricular tachycardia (VT) in the setting of postmyocardial infarction left ventricular aneurysms (LVA) is not uncommonly encountered, there is a scarcity of data regarding the safety, efficacy, and outcomes of ablation of VT in this subset of patients.MethodsOur study included consecutive patients aged 18 years or older with postmyocardial infarction LVA who presented to Mayo Clinic for catheter ablation of VT between 2002 and 2018.ResultsOf 34 patients, the mean age was 70.4 ± 9.1 years; 91% were male. Mean LVEF was 29 ± 9.7% and left ventricular end‐diastolic dimension was 64.9 ± 6.6 mm. The site of the LVA was apical in 21 patients (62%). Fifteen patients (44%) presented with electrical storm or incessant VT. Nine patients (26%) had a history of intracardiac thrombus. All except for one patient had at least one VT originating from the aneurysm. The mean number of VTs was 2.9 ± 1.7. All patients underwent ablation at the site of the aneurysm. Ablation outside the aneurysm was performed in 13 patients (38%). Low‐voltage fractionated potentials and/or late potentials at the aneurysmal site were present in all cases. Complete elimination of all VTs was achieved in 18 (53%), while the elimination of the clinical VT with continued inducibility of nonclinical VTs was achieved in a further 11 patients (32%). Two patients developed cardiac tamponade requiring pericardiocentesis. During a mean follow‐up period of 2.3 ± 2.4 years, 11 patients (32%) experienced VT recurrence. Freedom from all‐cause mortality at 1‐year follow‐up was 94%.ConclusionRadiofrequency catheter ablation targeting the aneurysmal site is a feasible and reasonably effective management strategy for clinical VTs in patients with postinfarction LVA.