Back to Authors

Cannon, Bryan C.

https://orcid.org/0000-0002-5380-5449

Mayo Clinic

Mayo Clinic

Citations 36

Human Stem Cell–Derived Cardiomyocytes Integrate Into the Heart of Monkeys With Right Ventricular Pressure Overload
Scholz, Jodi A. , Secreto, Frank J., Wobig, Joan, Kurian, Joe R, Hagen, Clint , Zinnen, Alexandra D. , Vu, Don, Johnson, Steven J., Cetta, Frank , Qureshi, M. Yasir , Reams, Rachel Y., Cannon, Bryan C. , Heyer, Christina M., Chang, Min‐Hwang , Fadra, Numrah, Coonen, Jennifer , Simmons, Heather A. , Mejía, Andrés , Hayes, Jennifer M. , Basu, Puja , Capuano, Saverio , Bondarenko, Viktoriya, Metzger, Jeanette M. , Nelson, Timothy J., Scholz, Jodi, Qureshi, Muhammad Y , Cannon, Bryan, Emborg, Marina E , Vu, Don, Johnson, Steven J., Nelson, Timothy J.

Cell Transplantation | November 2, 2024 | Volume: 33 | Issue: No issue available | Pages: No page available

10.1177/09636897241290367 Get It

Cardiac ventricular pressure overload affects patients with congenital heart defects and can cause cardiac insufficiency. Grafts of stem cell–derived cardiomyocytes are proposed as a complementary treatment to surgical repair of the cardiac defect, aiming to support ventricular function. Here, we report successful engraftment of human induced pluripotent stem cell–derived cardiac lineage cells into the heart of immunosuppressed rhesus macaques with a novel surgical model of right ventricular pressure overload. The human troponin+ grafts were detected in low-dose (2 × 10 6 cells/kg) and high-dose (10 × 10 6 cells/kg) treatment groups up to 12 weeks post-injection. Transplanted cells integrated and progressively matched the organization of the surrounding host myocardium. Ventricular tachycardia occurred in five out of 16 animals receiving cells, with episodes of incessant tachycardia observed in two animals; ventricular tachycardia events resolved within 19 days. Our results demonstrate that grafted cardiomyocytes mature and integrate into the myocardium of nonhuman primates modeling right ventricular pressure overload.
Outcomes and complications of transvenous implantable cardioverter defibrillator systems in the pediatric population: a systematic review and meta-analysis
Shah, Manan , Bar‐Cohen, Yaniv , Berul, Charles I., Boramanand, Nicole K., Cannon, Bryan C. , Kim, J J, Triedman, John K. , Saarel, Elizabeth V. , Arias, Katherine, Cerkvenik, Jeffrey , Shah, M, Arias, K, Dubin, Anne M.

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.3108 Get It

Abstract Background Implantable cardioverter defibrillators (ICDs) are an important therapy for prevention of sudden cardiac death (SCD). Data on transvenous (TV) ICD therapy rates, complications, and system survival in children ≤ 21 years is limited by absolute numbers and inclusion of adults with congenital heart disease. Purpose To determine ICD therapy rates and complications in pediatric patients ≤ 21 years of age. Methods A systematic review and meta-analysis were conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Medline, Embase, PubMed Ahead-of-Print and in-process records, and Cochrane Database of Systematic Reviews were searched for full-text articles on pediatric ICD. Articles were assessed for inclusion by two authors via a consensus process; the exclusion criteria included: case reports, review articles, abstracts, editorials, articles not in English, articles solely on epicardial or subcutaneous leads, articles on unrelated topics, articles with <50% ICD leads, and articles with any patients >21 years old. Data were extracted by 1 author and verified by a 2nd author. Meta-analysis of aggregate data was performed, where possible. Random effects models were used for pooled inferences. All reported rates are annualized rates based on reported follow-up times in each study. Results Of 1325 articles, 23 met all inclusion and no exclusion criteria (Figure) representing 1700 patients implanted from 1987-2020. The average age of patients was 12.8 years (95% confidence interval [CI]: 11.9 – 13.7) with weight of 51.1 kg (95% CI: 42.2 – 60.0) (Table). Primary prevention was the indication in 56.4 % (95% CI: 45.0% – 67.7%). Only 14.8% (95% CI: 10.6% – 19.0%) of the patients had congenital heart disease while 22.6% (95% CI: 15.8% – 29.3%) had long QT syndrome. The annualized rate of appropriate shock was 7.0% (95% CI: 5.6% – 8.8%) and the rate of inappropriate shock was 4.8% (95% CI: 3.8% – 6.0%). Annualized rates of reported adverse events included lead failure: 2.3% (95% CI: 1.6% – 3.3%) and infection: 0.8% (95% CI: 0.4% – 1.6%), which could have led to system revision: 4.4% (95% CI: 2.1% – 9.4%). The all-cause mortality rate was 0.8% (95% CI: 0.6% – 1.2%) across 17 studies. In 9 studies with 719 patients, the heart transplant rate was 1.6% (95% CI: 0.6% – 3.9%). Conclusion In this first systematic review and meta-analysis of ICDs in pediatric patients, ICD therapy was effective for prevention of SCD with a 7.0% annualized rate of appropriate ICD shocks. This is comparable to the annualized rate of appropriate ICD shock for secondary prevention of SCD in adult randomized controlled trials. Most common adverse events in the pediatric population were lead failure and system revision. Further refinements in patient selection criteria for implantation and improvements in lead and device technology are needed for pediatric patients.FigureTable
Vigorous Exercise in Patients With Congenital Long QT Syndrome: Results of the Prospective, Observational, Multinational LIVE-LQTS Study
Lampert, Rachel , Day, Sharlene M. , Ainsworth, Barbara E. , Burg, Matthew M. , Marino, Bradley S. , Salberg, Lisa , Tome, Maite , Abrams, Dominic J. , Aziz, Peter F. , Barth, Cheryl , Behr, Elijah R. , Bell, Cheyanne , Berul, Charles I. , Bos, J. Martijn , Cannom, David S. , Cannon, Bryan C. , Concannon, Maryann, Czosek, Richard J. , Dubin, Anne M. , Dziura, James , Erickson, Christopher C. , Etheridge, Susan P. , Gray, Belinda , Haglund-Turnquist, Carla , Johnsrude, Christopher L. , Lara, Alice, Saarel, Elizabeth V. , Sanatani, Shubhayan , Shah, Maully J. , Simone, Laura, Tomaselli, Gordon F., Ware, James S. , Zaręba, Wojciech , Ackerman, Michael J. , Day, Sharlene , Burg, Matthew , Tome Esteban, Maria Teresa , Bos, Johan M , Cannon, Bryan C , Cerrone, Marina , Czosek, Richard J , Dubin, Anne M , Dziura, James , Erickson, Christopher C , Estes, N.A. Mark , Etheridge, Susan P , Goldenberg, Ilan , Gray, Belinda , Haglund-Turnquist, Carla M , Harmon, Kimberly G , James, Cynthia A , Johnsrude, Christopher , Kannankeril, Prince J , Law, Ian H , Link, Mark S. , Molossi, Silvana M , Olshansky, Brian , Noseworthy, Peter A , Saarel, Elizabeth V , Sanatani, Shubhayan , Shah, Maully , Skinner, Jonathan R , Ware, James S , Webster, Gregory , Zareba, Wojciech , Zipes, Douglas P , Ackerman, Michael J , Behr, Elijah Raphael , Abrams, Dominic J , Bradley, David J. , Cerrone, Marina , Goldenberg, Ilan , Harmon, Kimberly G. , James, Cynthia A. , Kannankeril, Prince J. , Law, Ian H. , Li, Fangyong , Olshansky, Brian , Noseworthy, Peter A. , Skinner, Jonathan R. , Webster, Gregory , Zipes, Douglas P.

Circulation | July 25, 2024 | Volume: 150 | Issue: 7 | Pages: 516-530

10.1161/circulationaha.123.067590 Get It

BACKGROUND: Whether vigorous exercise increases risk of ventricular arrhythmias for individuals diagnosed and treated for congenital long QT syndrome (LQTS) remains unknown. METHODS: The National Institutes of Health–funded LIVE-LQTS study (Lifestyle and Exercise in the Long QT Syndrome) prospectively enrolled individuals 8 to 60 years of age with phenotypic and/or genotypic LQTS from 37 sites in 5 countries from May 2015 to February 2019. Participants (or parents) answered physical activity and clinical events surveys every 6 months for 3 years with follow-up completed in February 2022. Vigorous exercise was defined as ≥6 metabolic equivalents for >60 hours per year. A blinded Clinical Events Committee adjudicated the composite end point of sudden death, sudden cardiac arrest, ventricular arrhythmia treated by an implantable cardioverter defibrillator, and likely arrhythmic syncope. A National Death Index search ascertained vital status for those with incomplete follow-up. A noninferiority hypothesis (boundary of 1.5) between vigorous exercisers and others was tested with multivariable Cox regression analysis. RESULTS: Among the 1413 participants (13% <18 years of age, 35% 18–25 years of age, 67% female, 25% with implantable cardioverter defibrillators, 90% genotype positive, 49% with LQT1, 91% were treated with beta-blockers, left cardiac sympathetic denervation, and/or implantable cardioverter defibrillator), 52% participated in vigorous exercise (55% of these competitively). Thirty-seven individuals experienced the composite end point (including one sudden cardiac arrest and one sudden death in the nonvigorous group, one sudden cardiac arrest in the vigorous group) with overall event rates at 3 years of 2.6% in the vigorous and 2.7% in the nonvigorous exercise groups. The unadjusted hazard ratio for experience of events for the vigorous group compared with the nonvigorous group was 0.97 (90% CI, 0.57–1.67), with an adjusted hazard ratio of 1.17 (90% CI, 0.67–2.04). The upper 95% one-sided confidence level extended beyond the 1.5 boundary. Neither vigorous or nonvigorous exercise was found to be superior in any group or subgroup. CONCLUSIONS: Among individuals diagnosed with phenotypic and/or genotypic LQTS who were risk assessed and treated in experienced centers, LQTS-associated cardiac event rates were low and similar between those exercising vigorously and those not exercising vigorously. Consistent with the low event rate, CIs are wide, and noninferiority was not demonstrated. These data further inform shared decision-making discussions between patient and physician about exercise and competitive sports participation. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02549664.
Utilizing median and maximum QTc values improves prediction of breakthrough cardiac events in pediatric long QT syndrome
Rohatgi, Ram K., Tseng, Andrew S. , Sugrue, Alan , Lee, Alexander T. , Wackel, Phillip L., Cannon, Bryan C. , Bos, J. Martijn , Ackerman, Michael J. , Sugrue, Alan , Wackel, Philip , Ackerman, Michael J , Tseng, A S , Bos, Johan M , Scott, Christopher G.

Journal of Cardiovascular Electrophysiology | May 10, 2024 | Volume: 35 | Issue: 7 | Pages: 1370-1381

10.1111/jce.16293 Get It

AbstractIntroductionAlthough prior studies indicate that a QTc > 500 ms on a single baseline 12‐lead electrocardiogram (ECG) is associated with significantly increased risk of arrhythmic events in long QT syndrome (LQTS), less is known about the risk of persistent QT prolongation. We sought to determine QTc persistence and its prognostic effect on breakthrough cardiac events (BCEs) among pediatric patients treated for LQTS.MethodsWe performed a retrospective analysis of 433 patients with LQTS evaluated, risk‐stratified, and undergoing active guideline‐based LQTS treatment between 1999 and 2019. BCEs were defined as arrhythmogenic syncope/seizure, sudden cardiac arrest (SCA), appropriate VF‐terminating ICD shock, and sudden cardiac death (SCD).ResultsDuring the median follow‐up of 5.5 years (interquartile range [IQR] = 3–9), 32 (7%) patients experienced a total of 129 BCEs. A maximum QTc threshold of 520 ms and median QTc threshold of 490 ms were determined to be strong predictors for BCEs. A landmark analysis controlling for age, sex, genotype, and symptomatic status demonstrated models utilizing both the median QTc and maximum QTc demonstrated the highest discriminatory value (c‐statistic = 0.93–0.95). Patients in the high‐risk group (median QTc > 490 ms and maximum QTc > 520 ms) had a significantly lower BCE free survival (70%–81%) when compared to patients in both medium‐risk (93%–97%) and low‐risk (98%–99%) groups.ConclusionsThe risk of BCE among patients treated for LQTS increases not only based upon their maximum QTc, but also their median QTc (persistence of QTc prolongation). Patients with a maximum QTc > 520 ms and median QTc > 490 ms over serial 12‐lead ECGs are at the highest risk of BCE while on guideline‐directed medical therapy.
Abstract 8952: Results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study
Berul, Charles I. , Freedenberg, Vicki , Balaji, Seshadri, Bar‐Cohen, Yaniv , Batra, Anjan S. , Cannon, Bryan C. , Ceresnak, Scott R. , Collins, Kathryn K. , Erickson, Christopher C. , Franklin, Wayne H., Kertesz, Naomi J. , Moak, Jeffrey P. , Papagiannis, John , Paul, Thomas , Tanel, Ronn E. , Tisma-Dupanovic, Svetlana, Zimmerman, Frank, Cecchin, Frank , Atallah, Joseph , Balaji, Seshadri , Chun, Terrence , Dubin, Anne M. , LaPage, Martin J , Law, Ian H. , Tisma‐Dupanovic, Svetlana, Wilkoff, Bruce L.

Circulation | April 23, 2024 | Volume: 124 | Issue: suppl_21 | Pages: No page available

10.1161/circ.124.suppl_21.a8952 Get It

Implantable cardioverter-defibrillator (ICD) therapy in children and congenital heart disease (CHD) patients is hampered by poor long-term lead survival. Lead extraction is technically difficult and carries substantial morbidity. Manufacturers developed distinct strategies for this issue: thinner lead bodies or a Gore ePTFE coil coating. Both design changes were thought to improve ease of lead removal, but have not been directly compared in children or adults. The purpose of this study was to assess thin and ePTFE-coated ICD lead survival in pediatric and CHD pts. Methods: The Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study began as a Phase IV multicenter open-label prospective study [ NCT00335036 ], facilitated by the Pediatric & Congenital EP Society. Initially designed as a randomized study, it changed to a parallel assignment registry when 1 lead had an advisory due to high incidence of failure, prompting concern about continued clinical equipoise. Pediatric and CHD pts who underwent ICD lead implant from 2005-2010 were eligible. The end date was NCDR ICD Registry v2.0 release (includes pediatric & lead data). 23 centers participated; each site obtained IRB approval. De-identified data was sent to the PI center for verification and statistical analyses. Results: A total of 982 ICD pts (357 VVI, 558 DDD, 67 CRT-D) entered the PLEASE study, incl. 423 pts (43%) with CHD. Mean age at implant = 18.3 ± 9.9 yrs. Thin (< 7Fr) ICD leads accounted for 51%, 23% were ePTFE-coated, 26% neither thin nor coated. There were 113 ICD lead failures (11.5%) at a mean lead-age of 2.2 ± 1.7 yrs, causing shocks in 55 pts. Failure occurred in 21% of thin leads vs 3.5% of ePTFE leads (p<0.01). Extraction was performed on 142 (14.5%) leads overall; 21% of thin leads (incl. extraction of 29 functioning leads due to recall) vs. 4.4% of ePTFE leads (p<0.01). There were 7 major extraction complications (4.9%), but no procedural mortality. Among thin leads, 90/270 (33.3%) of recalled leads failed vs 15/229 (6.6%) non-recalled thin leads. Conclusions: This Phase IV study demonstrates that ICD leads in children and CHD pts have suboptimal performance overall. Thinner leads were much more likely to fail and/or be extracted compared with ePTFE leads, chiefly driven by one lead type.
Utility of routine follow‐up defibrillation safety margin testing in young patients with epicardial implantable cardioverter‐defibrillators
Leng, Tomas , Stephens, Elizabeth H. , Cannon, Bryan C. , Ackerman, Michael J. , Wackel, Philip L. , Griffeth, Elaine, Cannon, Bryan C , Wackel, Philip , Griffeth, Elaine M. , Dearani, Joseph A.

Pacing and Clinical Electrophysiology | February 11, 2024 | Volume: 47 | Issue: 3 | Pages: 392-397

10.1111/pace.14948 Get It

AbstractBackgroundRoutine defibrillation threshold testing (DFT) of transvenous implantable defibrillators (ICDs) has largely been in decline. In patients with non‐transvenous ICDs that utilize subcutaneous and pleural ICD leads, serial DFT testing can detect a significant number of failures. Data about the utility of follow‐up defibrillation safety margin testing (DSM) testing in pediatric patients and young adults with an epicardial ICD are lacking.MethodsPatients aged < 25 years old who underwent epicardial ICD placement at Mayo Clinic from 2014 to 2023 with at least one follow‐up DSM test were included. The patients were divided into a “routine” (R) and “clinically indicated” (CI) group based on the index of clinical concern. Inadequate DSM was defined as unsuccessful defibrillation at an output of less than 10 J below the maximum output of the device. The purpose of this study was to assess the utility of follow‐up DSM testing.ResultsAn epicardial ICD system was placed in 122 patients. A total of 26 patients met inclusion criteria and underwent a total of 47 DSM follow up tests. Inadequate DSM occurred in 1/33 (3%) in the R group and 2/14 (14%) DSM tests in the CI group. The median follow‐up period was 54 and 36 months for the R and CI group, respectively.ConclusionsOur data suggest that epicardial ICDs are reliable and routine follow‐up DSM testing may not be necessary for all patients. DSM testing should be performed in individuals with epicardial ICD systems when there is clinical concern about lead or coil performance.
Aortic Dissection in a Young Patient With Unsuspected Aortopathy
Perez, Yalile , Qureshi, M. Yasir , Babovic‐Vuksanovic, Dusica , Cannon, Bryan C. , Qureshi, Muhammad Y

Pediatrics | July 14, 2023 | Volume: 152 | Issue: 2 | Pages: No page available

10.1542/peds.2022-057694 Get It

Aortic dissection is often a fatal condition if not recognized and treated emergently. Fortunately, it is extremely rare in children and adolescents. We report a case of an adolescent boy who survived an aortic dissection due to severe aortic root dilation. A comprehensive history and physical examination, including family history, can facilitate an early diagnosis of connective tissue diseases, such as Loeys-Dietz syndrome (LDS).
Pediatric Epicardial Devices: Early and Midterm Outcomes
Griffeth, Elaine M. , Krishnan, Prasad , Dearani, Joseph A. , Ackerman, Michael J. , Wackel, Philip L. , Cannon, Bryan C. , Dearani, Joseph A. , Pahwa, Siddharth , Todd, Austin W.

World Journal for Pediatric and Congenital Heart Surgery | March 5, 2023 | Volume: 14 | Issue: 4 | Pages: 451-458

10.1177/21501351231157374 Get It

Background Lead performance is suboptimal in young patients and a main cause of device system failure. Our objective was to assess early and midterm outcomes after epicardial device implantation in a contemporary pediatric cohort. Methods A total of 116 consecutive pediatric patients underwent 137 epicardial device implantations from 2010 to 2019. Forty pacemakers and 97 implantable cardioverter defibrillators (ICDs) were implanted. Lead failure was defined as leads repaired, replaced, or abandoned due to fracture, dislodgement, or dysfunction. Freedom from device system failure was determined using Kaplan-Meier analysis. Results Mean age at implantation was 10 ± 5 years, 46 (34%) were younger than 8 years old, 41 (30%) had prior cardiac surgery, and 38 (28%) had prior devices. Main indications were acquired heart block (17/40 [43%]), sinus node dysfunction (14/40 [35%]), and congenital heart block (7/40 [18%]) for pacemakers, and hypertrophic cardiomyopathy (46/97 [47%]), long QT syndrome (31/97 [32%]), and ventricular arrhythmia (17/97 [18%]) for ICDs. There were no early deaths. Three-year freedom from device system failure was 80% (95% CI 73%, 88%) for all patients and 88% (95% CI 79%, 99%) for patients <8 years old. Device system failure causes included lead fracture (20/34 [59%]), lead dysfunction (5/34 [15%]), lead dislodgement (5/34 [15%]), infection (3/34 [9%]), and pericarditis (1/34 [3%]). Reintervention was required in 26/34 (76%) device system failures. Conclusions Epicardial device implantation is safe, shows acceptable midterm outcomes in children, and is an effective option in patients younger than 8 years old. Close device surveillance continues to be essential to detect lead failure early and ensure timely reintervention.
Pediatric Electrophysiology Device Needs: A Survey from the Pediatric and Congenital Electrophysiology Society Taskforce on Pediatric‐Specific Devices
Dubin, Anne M. , Bar‐Cohen, Yaniv , Berul, Charles I. , Cannon, Bryan C. , Saarel, Elizabeth V. , Shah, Maully J. , Triedman, John K. , Saarel, Elizabeth V , Dubin, Anne M

Journal of the American Heart Association | November 3, 2022 | Volume: 11 | Issue: 22 | Pages: No page available

10.1161/jaha.122.026904 Get It

Background There are few US Food and Drug Administration (FDA)–approved devices specifically aimed at the pediatric patient with arrhythmia. This has led to a high off‐label utilization of devices in this vulnerable population. The Pediatric and Congenital Electrophysiology Society (PACES), the international organization representing pediatric and congenital heart disease arrhythmia specialists, developed a task force to comprehensively address device development issues relevant to pediatric patients with congenital arrhythmia. Methods and Results As a first step, the taskforce developed a 26‐question survey for the pediatric arrhythmia community to assess providers’ understanding of the FDA approval process, specifically in regard to pediatric labeling. There were 92/211 respondents (44%) with a >90% completion rate. The vast majority of respondents believed there was a paucity of devices available for children (96%). More than 60% of respondents stated that they did not understand the FDA regulatory process and were not aware of whether the devices they used were labeled for pediatric use. Conclusions Pediatric electrophysiologists are keenly aware of the deficit of available pediatric devices for their patients. The majority do not understand the FDA approval process and could benefit from additional educational resources regarding this. A collaborative forum including PACES, FDA, patients and their families, and Industry would be an important next step in clarifying opportunities and priorities to serve this vulnerable population.
Cardiac Implantable Electronic Devices in Ebstein Anomaly: Management and Outcomes
Tan, Nicholas Y. , Amin, Mustapha, McLeod, Christopher J. , Stephens, Elizabeth H. , Cannon, Bryan C. , Miranda, William R. , Connolly, Heidi M. , Egbe, Alexander C. , Asirvatham, Samuel J. , Madhavan, Malini , McLeod, Christopher J , Stephens, Elizabeth H , Miranda, William R , Connolly, Heidi M , Egbe, Alexander C , Asirvatham, Samuel J , Madhavan, Malini , Dearani, Joseph A.

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010744 Get It

Background: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. Methods: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. Results: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P =0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. Conclusions: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.