Back to Authors

Cerkvenik, Jeffrey

https://orcid.org/0000-0003-1664-8912

Mayo Clinic

Medtronic (United States)

Citations 3

Outcomes and complications of transvenous implantable cardioverter defibrillator systems in the pediatric population: a systematic review and meta-analysis
Shah, Manan , Bar‐Cohen, Yaniv , Berul, Charles I., Boramanand, Nicole K., Cannon, Bryan C. , Kim, J J, Triedman, John K. , Saarel, Elizabeth V. , Arias, Katherine, Cerkvenik, Jeffrey , Shah, M, Arias, K, Dubin, Anne M.

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.3108 Get It

Abstract Background Implantable cardioverter defibrillators (ICDs) are an important therapy for prevention of sudden cardiac death (SCD). Data on transvenous (TV) ICD therapy rates, complications, and system survival in children ≤ 21 years is limited by absolute numbers and inclusion of adults with congenital heart disease. Purpose To determine ICD therapy rates and complications in pediatric patients ≤ 21 years of age. Methods A systematic review and meta-analysis were conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Medline, Embase, PubMed Ahead-of-Print and in-process records, and Cochrane Database of Systematic Reviews were searched for full-text articles on pediatric ICD. Articles were assessed for inclusion by two authors via a consensus process; the exclusion criteria included: case reports, review articles, abstracts, editorials, articles not in English, articles solely on epicardial or subcutaneous leads, articles on unrelated topics, articles with <50% ICD leads, and articles with any patients >21 years old. Data were extracted by 1 author and verified by a 2nd author. Meta-analysis of aggregate data was performed, where possible. Random effects models were used for pooled inferences. All reported rates are annualized rates based on reported follow-up times in each study. Results Of 1325 articles, 23 met all inclusion and no exclusion criteria (Figure) representing 1700 patients implanted from 1987-2020. The average age of patients was 12.8 years (95% confidence interval [CI]: 11.9 – 13.7) with weight of 51.1 kg (95% CI: 42.2 – 60.0) (Table). Primary prevention was the indication in 56.4 % (95% CI: 45.0% – 67.7%). Only 14.8% (95% CI: 10.6% – 19.0%) of the patients had congenital heart disease while 22.6% (95% CI: 15.8% – 29.3%) had long QT syndrome. The annualized rate of appropriate shock was 7.0% (95% CI: 5.6% – 8.8%) and the rate of inappropriate shock was 4.8% (95% CI: 3.8% – 6.0%). Annualized rates of reported adverse events included lead failure: 2.3% (95% CI: 1.6% – 3.3%) and infection: 0.8% (95% CI: 0.4% – 1.6%), which could have led to system revision: 4.4% (95% CI: 2.1% – 9.4%). The all-cause mortality rate was 0.8% (95% CI: 0.6% – 1.2%) across 17 studies. In 9 studies with 719 patients, the heart transplant rate was 1.6% (95% CI: 0.6% – 3.9%). Conclusion In this first systematic review and meta-analysis of ICDs in pediatric patients, ICD therapy was effective for prevention of SCD with a 7.0% annualized rate of appropriate ICD shocks. This is comparable to the annualized rate of appropriate ICD shock for secondary prevention of SCD in adult randomized controlled trials. Most common adverse events in the pediatric population were lead failure and system revision. Further refinements in patient selection criteria for implantation and improvements in lead and device technology are needed for pediatric patients.FigureTable
Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial
Haines, David E. , Boersma, Lucas V.A. , Sood, Nitesh , Natale, Andrea , Marchlinski, Francis E. , Calkins, Hugh , Sanders, Prashanthan , Packer, Douglas L. , Kuck, Karl-Heinz , Hindricks, Gerhard , Önal, Birce , Cerkvenik, Jeffrey , Tada, Hiroshi , Investigators, on behalf of the PULSED AF, Verma, Atul , Boersma, Lucas , Natale, Andrea , Marchlinski, Francis E , Calkins, Hugh , Sanders, Prashanthan , Packer, Douglas L , Kuck, Karl-Heinz , Onal, Birce , Verma, Atul , DeLurgio, David B. , Investigators, on behalf of the PULSED AF

Circulation | March 6, 2023 | Volume: 147 | Issue: 19 | Pages: 1422-1432

10.1161/circulationaha.123.063988 Get It

Background: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. Methods: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. Results: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. Conclusions: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04198701.
Effects of Cardiac Resynchronization Therapy on Cardiac Remodeling and Contractile Function: Results From Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction (REVERSE)
Sutton, Martin St. John, Cerkvenik, Jeffrey , Borlaug, Barry A. , Daubert, Claude , Gold, Michael R. , Ghio, Stefano , Chirinos, Julio A. , Linde, Cecilia , Ky, Bonnie , Borlaug, Barry A , Ky, Bonnie , Ghio, Stefano

Journal of the American Heart Association | September 14, 2018 | Volume: 4 | Issue: 9 | Pages: No page available

10.1161/jaha.115.002054 Get It

Background Cardiac resynchronization therapy results in improved ejection fraction in patients with heart failure. We sought to determine whether these effects were mediated by changes in contractility, afterload, or volumes. Methods and Results In 610 patients with New York Heart Association class I/ II heart failure from the Re synchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction ( REVERSE ) study, we performed detailed quantitative echocardiography assessment prior to and following cardiac resynchronization therapy. We derived measures of contractility (the slope [end‐systolic elastance] and the volume intercept of the end‐systolic pressure–volume relationship, stroke work, and preload recruitable stroke work), measures of arterial load and ventricular–arterial coupling, and measures of chamber size (volume intercept, end‐systolic and end‐diastolic volumes). At 6 and 12 months, cardiac resynchronization therapy was associated with a reduction in the volume intercept and end‐systolic and end‐diastolic volumes ( P <0.01). There were no consistent effects on end‐systolic elastance, stroke work, preload recruitable stroke work, or ventricular–arterial coupling. In the active cardiac resynchronization therapy population, baseline measures of arterial load were associated with the clinical composite score (odds ratio 1.30, 95% CI 1.04 to 1.63, P =0.02). The volume intercept was associated with mortality (hazard ratio 1.90, 95% CI 1.01 to 3.59, P =0.047) and more modestly with the combined end point of mortality or heart failure hospitalization (hazard ratio 1.48, 95% CI 0.8 to 2.25, P =0.06). In contrast, end‐systolic elastance, stroke work, preload recruitable stroke work, and ventricular–arterial coupling were not associated with any outcomes. Conclusion In patients with NYHA Class I/ II heart failure, cardiac resynchronization therapy exerts favorable changes in left ventricular end‐systolic and end‐diastolic volumes and the volume intercept. The volume intercept may be useful to gain insight into prognosis in heart failure. Clinical Trial Registration URL : https://www.clinicaltrials.gov/ . Unique identifier: NCT 00271154.