Background: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. Methods: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. Results: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. Conclusions: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04198701.
Two‐Year Outcomes With a Next‐Generation Left Atrial Appendage Device: Final Results of the PINNACLE FLX Trial
Background The PINNACLE FLX (Protection Against Embolism for Non‐valvular AF [Atrial Fibrillation] Patients: Investigational Device Evaluation of the Watchman FLX LAA [Left Atrial Appendage] Closure Technology) trial evaluated the safety and efficacy of a next‐generation left atrial appendage closure device (WATCHMAN FLX; Boston Scientific, Marlborough, MA). At 1 year, the study met the primary end points of safety and anatomical efficacy/appendage closure. This final report of the PINNACLE FLX trial includes the prespecified secondary end point of ischemic stroke or systemic embolism at 2 years, also making it the first report of 2‐year outcomes with this next‐generation left atrial appendage closure device. Methods and Results Patients with nonvalvular atrial fibrillation with CHA 2 DS 2 ‐VASc score ≥2 (men) or ≥3 (women), with an appropriate rationale for left atrial appendage closure, were enrolled to receive the left atrial appendage closure device at 29 US centers. Adverse events were assessed by an independent clinical events committee, and imaging was assessed by independent core laboratories. Among 395 implanted patients (36% women; mean age, 74 years; CHA 2 DS 2 ‐VASc, 4.2±1.5), the secondary efficacy end point of 2‐year ischemic stroke or systemic embolism was met, with an absolute rate of 3.4% (annualized rate, 1.7%) and an upper 1‐sided 95% confidence bound of 5.3%, which was superior to the 8.7% performance goal. Two‐year rates of adverse events were as follows: 9.3% all‐cause mortality, 5.5% cardiovascular death, 3.4% all stroke, and 10.1% major bleeding (Bleeding Academic Research Consortium 3 or 5). There were no additional systemic embolisms, device embolizations, pericardial effusions, or symptomatic device‐related thrombi after 1 year. Conclusions The secondary end point of 2‐year stroke or systemic embolism was met at 3.4%. In these final results of the PINNACLE FLX trial, the next‐generation WATCHMAN FLX device demonstrated favorable safety and efficacy outcomes.