Back to Authors

Téllez-Plaza, María

https://orcid.org/0000-0002-3850-1228

Mayo Clinic

Johns Hopkins University

Citations 2

Two‐Year Outcomes With a Next‐Generation Left Atrial Appendage Device: Final Results of the PINNACLE FLX Trial
Doshi, Shephal K. , Kar, Saibal , Sadhu, Ashish, Horton, Rodney , Osorio, José , Ellis, Christopher R. , Stone, James, Shah, Manish H. , Dukkipati, Srinivas R. , Adler, Stuart W., Kim, Jamie , Wazni, Oussama M. , Holmes, David R. , Shipley, Robert D., Christen, Thomas, Allocco, Dominic J. , Buchbinder, Maurice , Chinitz, Larry A. , Desai, Amish J., Dukkipatti, Srinivas R., Ellis, Christopher, Gibson, Douglas , Huber, Kenneth, Khairallah, Farhat, Koneru, Jayanthi N. , Mahoney, Paul G. , Mansour, Moussa , Mark, George E., Nicholson, William , REISS, J. A., Shehata, Michael , Swarup, Vijendra, Huber, Kurt , Téllez-Plaza, María , Ellis, Christopher , Shah, Manish , Nair, Devi G , Wazni, Oussama , Price, Matthew J , Holmes, David R , Reddy, Vivek Y , Kar, Saibal , Huber, Kurt , Price, Matthew J. , Reddy, Vivek Y. , DeLurgio, David B. , Ellis, Christopher, Huber, Kenneth, Mahoney, Paul, O’Neill, William W. , Reiss, James, Saliba, Walid I.

Journal of the American Heart Association | February 21, 2023 | Volume: 12 | Issue: 4 | Pages: No page available

10.1161/jaha.122.026295 Get It

Background The PINNACLE FLX (Protection Against Embolism for Non‐valvular AF [Atrial Fibrillation] Patients: Investigational Device Evaluation of the Watchman FLX LAA [Left Atrial Appendage] Closure Technology) trial evaluated the safety and efficacy of a next‐generation left atrial appendage closure device (WATCHMAN FLX; Boston Scientific, Marlborough, MA). At 1 year, the study met the primary end points of safety and anatomical efficacy/appendage closure. This final report of the PINNACLE FLX trial includes the prespecified secondary end point of ischemic stroke or systemic embolism at 2 years, also making it the first report of 2‐year outcomes with this next‐generation left atrial appendage closure device. Methods and Results Patients with nonvalvular atrial fibrillation with CHA 2 DS 2 ‐VASc score ≥2 (men) or ≥3 (women), with an appropriate rationale for left atrial appendage closure, were enrolled to receive the left atrial appendage closure device at 29 US centers. Adverse events were assessed by an independent clinical events committee, and imaging was assessed by independent core laboratories. Among 395 implanted patients (36% women; mean age, 74 years; CHA 2 DS 2 ‐VASc, 4.2±1.5), the secondary efficacy end point of 2‐year ischemic stroke or systemic embolism was met, with an absolute rate of 3.4% (annualized rate, 1.7%) and an upper 1‐sided 95% confidence bound of 5.3%, which was superior to the 8.7% performance goal. Two‐year rates of adverse events were as follows: 9.3% all‐cause mortality, 5.5% cardiovascular death, 3.4% all stroke, and 10.1% major bleeding (Bleeding Academic Research Consortium 3 or 5). There were no additional systemic embolisms, device embolizations, pericardial effusions, or symptomatic device‐related thrombi after 1 year. Conclusions The secondary end point of 2‐year stroke or systemic embolism was met at 3.4%. In these final results of the PINNACLE FLX trial, the next‐generation WATCHMAN FLX device demonstrated favorable safety and efficacy outcomes.
Ethnic, Geographic, and Genetic Differences in Arsenic Metabolism at Low Arsenic Exposure: A Preliminary Analysis in the Multi-Ethnic Study of Atherosclerosis (MESA)
Balakrishnan, Poojitha , Jones, Miranda R. , Téllez-Plaza, María , Kaufman, Joel D. , Bielinski, Suzette J. , Goessler, Walter , Goessler, Walter , Bielinski, Suzette , Kaufman, Joel D , Vaidya, Dhananjay , Post, Wendy S. , Taylor, Kent D. , Francesconi, Kevin A. , Navas‐Acién, Ana , Jones, Miranda R

International Journal of Environmental Research and Public Health | June 5, 2018 | Volume: 15 | Issue: 6 | Pages: 1179

10.3390/ijerph15061179 Get It

We investigated the effect of candidate variants in AS3MT (arsenic (III) methyltransferase) with urinary arsenic metabolites and their principal components in a subset of 264 participants in the Multi-Ethnic Study of Atherosclerosis (MESA). Urinary arsenic species, including inorganic arsenic (iAs), monomethylarsonate (MMA), dimethylarsinate (DMA), and arsenobetaine (Ab), were measured using high performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and corrected for organic sources from seafood consumption by regressing Ab on arsenic species using a validated method. Principal components of arsenic metabolism were also used as independent phenotypes. We conducted linear regression of arsenic traits with allelic dosage of candidate single nucleotide polymorphisms (SNPs) rs12768205 (G > A), rs3740394 (A > G), and rs3740393 (G > C) measured using Illumina MetaboChip. Models were stratified by non-Hispanic white vs. all other race/ethnicity and adjusted for age, sex, arsenic exposure, study site, and population stratification. Consistent with previous studies, rs12768205 showed evidence for strongest association (non-Hispanic white: iAs% −0.14 (P 0.83), MMA% −0.66 (0.49), DMA% 0.81(0.49); other race/ethnicity: 0.13 (0.71), −1.21 (0.09), 1.08 (0.20)). No association, however, passed the strict Bonferroni p-value. This was a novel study among an ethnically diverse population exposed to low arsenic levels.