Back to Authors

Sadhu, Ashish

Mayo Clinic

North Mississippi Medical Center

Citations 2

Two‐Year Outcomes With a Next‐Generation Left Atrial Appendage Device: Final Results of the PINNACLE FLX Trial
Doshi, Shephal K. , Kar, Saibal , Sadhu, Ashish, Horton, Rodney , Osorio, José , Ellis, Christopher R. , Stone, James, Shah, Manish H. , Dukkipati, Srinivas R. , Adler, Stuart W., Kim, Jamie , Wazni, Oussama M. , Holmes, David R. , Shipley, Robert D., Christen, Thomas, Allocco, Dominic J. , Buchbinder, Maurice , Chinitz, Larry A. , Desai, Amish J., Dukkipatti, Srinivas R., Ellis, Christopher, Gibson, Douglas , Huber, Kenneth, Khairallah, Farhat, Koneru, Jayanthi N. , Mahoney, Paul G. , Mansour, Moussa , Mark, George E., Nicholson, William , REISS, J. A., Shehata, Michael , Swarup, Vijendra, Huber, Kurt , Téllez-Plaza, María , Ellis, Christopher , Shah, Manish , Nair, Devi G , Wazni, Oussama , Price, Matthew J , Holmes, David R , Reddy, Vivek Y , Kar, Saibal , Huber, Kurt , Price, Matthew J. , Reddy, Vivek Y. , DeLurgio, David B. , Ellis, Christopher, Huber, Kenneth, Mahoney, Paul, O’Neill, William W. , Reiss, James, Saliba, Walid I.

Journal of the American Heart Association | February 21, 2023 | Volume: 12 | Issue: 4 | Pages: No page available

10.1161/jaha.122.026295 Get It

Background The PINNACLE FLX (Protection Against Embolism for Non‐valvular AF [Atrial Fibrillation] Patients: Investigational Device Evaluation of the Watchman FLX LAA [Left Atrial Appendage] Closure Technology) trial evaluated the safety and efficacy of a next‐generation left atrial appendage closure device (WATCHMAN FLX; Boston Scientific, Marlborough, MA). At 1 year, the study met the primary end points of safety and anatomical efficacy/appendage closure. This final report of the PINNACLE FLX trial includes the prespecified secondary end point of ischemic stroke or systemic embolism at 2 years, also making it the first report of 2‐year outcomes with this next‐generation left atrial appendage closure device. Methods and Results Patients with nonvalvular atrial fibrillation with CHA 2 DS 2 ‐VASc score ≥2 (men) or ≥3 (women), with an appropriate rationale for left atrial appendage closure, were enrolled to receive the left atrial appendage closure device at 29 US centers. Adverse events were assessed by an independent clinical events committee, and imaging was assessed by independent core laboratories. Among 395 implanted patients (36% women; mean age, 74 years; CHA 2 DS 2 ‐VASc, 4.2±1.5), the secondary efficacy end point of 2‐year ischemic stroke or systemic embolism was met, with an absolute rate of 3.4% (annualized rate, 1.7%) and an upper 1‐sided 95% confidence bound of 5.3%, which was superior to the 8.7% performance goal. Two‐year rates of adverse events were as follows: 9.3% all‐cause mortality, 5.5% cardiovascular death, 3.4% all stroke, and 10.1% major bleeding (Bleeding Academic Research Consortium 3 or 5). There were no additional systemic embolisms, device embolizations, pericardial effusions, or symptomatic device‐related thrombi after 1 year. Conclusions The secondary end point of 2‐year stroke or systemic embolism was met at 3.4%. In these final results of the PINNACLE FLX trial, the next‐generation WATCHMAN FLX device demonstrated favorable safety and efficacy outcomes.
Primary Outcome Evaluation of a Next-Generation Left Atrial Appendage Closure Device
Kar, Saibal , Doshi, Shephal K. , Sadhu, Ashish, Horton, Rodney , Osorio, José , Stone, James, Shah, Manish H. , Dukkipati, Srinivas R. , Adler, Stuart W., Kim, Jamie , Wazni, Oussama M. , Price, Mathew J., Holmes, David R. , Shipley, Robert D., Gordon, Nicole, Allocco, Dominic J. , Investigators, On behalf of the PINNACLE FLX, Kar, Saibal , Ellis, Christopher R. , Nair, Devi G , Asch, Federico M. , Reddy, Vivek Y. , Investigators, On behalf of the PINNACLE FLX

Circulation | April 6, 2021 | Volume: 143 | Issue: 18 | Pages: 1754-1762

10.1161/circulationaha.120.050117 Get It

Background: Left atrial appendage (LAA) occlusion provides an alternative to oral anticoagulation for thromboembolic risk reduction in patients with nonvalvular atrial fibrillation. Since regulatory approval in 2015, the WATCHMAN device has been the only LAA closure device available for clinical use in the United States. The PINNACLE FLX study (Protection Against Embolism for Nonvalvular AF Patients: Investigational Device Evaluation of the Watchman FLX LAA Closure Technology) evaluated the safety and effectiveness of the next-generation WATCHMAN FLX LAA closure device in patients with nonvalvular atrial fibrillation in whom oral anticoagulation is indicated, but who have an appropriate rationale to seek a nonpharmaceutical alternative. Methods: This was a prospective, nonrandomized, multicenter US Food and Drug Administration study. The primary safety end point was the occurrence of one of the following events within 7 days after the procedure or by hospital discharge, whichever was later: death, ischemic stroke, systemic embolism, or device- or procedure-related events requiring cardiac surgery. The primary effectiveness end point was the incidence of effective LAA closure (peri-device flow ≤5 mm), as assessed by the echocardiography core laboratory at 12-month follow-up. Results: A total of 400 patients were enrolled. The mean age was 73.8±8.6 years and the mean CHA 2 DS 2 -VASc score was 4.2±1.5. The incidence of the primary safety end point was 0.5% with a 1-sided 95% upper CI of 1.6%, meeting the performance goal of 4.2% ( P <0.0001). The incidence of the primary effectiveness end point was 100%, with a 1-sided 95% lower CI of 99.1%, again meeting the performance goal of 97.0% ( P <0.0001). Device-related thrombus was reported in 7 patients, no patients experienced pericardial effusion requiring open cardiac surgery, and there were no device embolizations. Conclusions: LAA closure with this next-generation LAA closure device was associated with a low incidence of adverse events and a high incidence of anatomic closure. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02702271.