Abstract 4361539: Long-term Outcomes of Leadless versus Transvenous Single-chamber Pacemaker in Elderly Patients
Sin, Yuh Miin, Singh, Ravnit, Deshmukh, Abhishek , Sroubek, Jakub , Wazni, Oussama M. , Lee, Justin Z. , Tan, Min Choon , Vignarajah, Aravinthan , Sin, Yuh Miin, DeSimone, Christopher V. , Santangeli, Pasquale

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4361539 Get It

Background: Leadless pacemaker has emerged as a promising alternative to traditional transvenous pacemaker (PM) among elderly patients who are at high risk of complications. Objective: This study aims to assess and compare 5-year clinical outcomes of leadless PM versus transvenous single-chamber PM in elderly patients using a multi-national dataset. Methods: Using the TriNetX Analytics Research Network, we included patients aged ≥65 years who underwent leadless versus transvenous single-chamber PM implantation between 1/1/2014 and 1/1/2020. Propensity score matching (PSM) was performed by using patient’s demographic, LVEF, cardiac comorbidities, and medications. The study outcomes included all-cause mortality and adverse cardiovascular events over a 5-year follow-up period. Results: After PSM, 7,501 patients in each group were analyzed. Leadless PM was associated with a significantly lower odds of 5-year all-cause mortality (odds ratio [OR]: 0.534; 95% confidence interval [CI]: 0.497-0.575), heart failure exacerbation (OR: 0.779, 95% CI: 0.721-0.841), major bleeding (OR: 0.666, 95% CI: 0.604-0.734), cardiac arrest (OR: 0.747, 95% CI: 0.646-0.864) and stroke (OR: 0.825, 95% CI: 0.750-0.908) compared to transvenous single-chamber PM. No significant difference was observed between the two groups in all-cause hospitalization (OR: 1.006, 95%CI: 0.938-1.079), cardiac thrombus (OR: 1.077, 95%CI: 0.791-1.465) or venous thromboembolism (OR: 1.028, 95%CI: 0.916-1.153). Conclusion: Leadless PM was associated with significantly improved mortality and cardiovascular outcomes compared to transvenous single-chamber PM in elderly patients. These findings support the strong consideration of leadless pacing as a strategy to reduce mortality and improve clinical outcomes in this high-risk population.
Left Ventricular Entry to Reduce Brain Lesions During Catheter Ablation: A Randomized Trial
Marcus, Gregory M. , Tung, Roderick , Gerstenfeld, Edward P. , Hue, Trisha F. , Lin, Feng , Cheng, Jing , Weiss, J. Peter , Tzou, Wendy S. , Hsia, Henry H. , Ehdaie, Ashkan , Cooper, Daniel H. , Bunch, T. Jared , Arkles, Jeffrey , Lee, Adam , Hadjis, Alexios , Nguyen, Duy T. , Chelu, Mihail G. , Valderrábano, Miguel , Bhave, Prashant D. , Beaser, Andrew D. , Kanagasundram, Arvindh N. , Wazni, Oussama M. , Bradfield, Jason S. , Wall, Grace, Chang, Kathleen , Yang, Michelle, Montenegro, Gabrielle, Jarrott, Sabrina, Kramer, Joel H. , Kim, Anthony , Morris, Yonca, Dillon, W.P. , Hsia, Henry , Nazer, Babak , Lee, Adam , Hadjis, Alexios , Chelu, Mihail G , Hsu, Jonathan C , Valderrábano, Miguel , Bhave, Prashant D , Beaser, Andrew D , Kanagasundram, Arvindh , Wazni, Oussama , Chang, Kathleen , Jarrott, Sabrina , Kim, Anthony S , Dillon, William P , Tzou, Wendy , Weiss, Peter J , Marcus, Gregory M , Moss, Joshua D. , Hsu, Jonathan C. , Montenegro, Gabrielle C , Morris, Yvonne M.

Circulation | February 24, 2025 | Volume: 151 | Issue: 15 | Pages: 1051-1059

10.1161/circulationaha.124.071352 Get It

BACKGROUND: Catheter ablation of ventricular arrhythmias, one of the most rapidly growing procedures in cardiac electrophysiology, is associated with magnetic resonance imaging–detected brain lesions in more than half of cases. Although a retrograde aortic approach is conventional, modern tools enable entry through a transseptal approach that may avoid embolization of debris from the arterial system. We sought to test the hypothesis that a transseptal puncture would mitigate brain injury compared with a retrograde aortic approach. METHODS: The TRAVERSE trial (Transseptal Versus Retrograde Aortic Ventricular Entry to Reduce Systemic Emboli) was a multicenter randomized controlled comparative effectiveness trial. Patients with left ventricular arrhythmias undergoing catheter ablation procedures were randomly assigned to a transseptal puncture approach compared (1:1) with a retrograde aortic approach. The primary outcome was the presence of an acute brain lesion detected by magnetic resonance imaging. Secondary outcomes included clinically manifest complications, procedural efficacy, and 6-month neurocognitive assessments. RESULTS: Among the 62 patients randomly assigned to a retrograde aortic approach with postoperative brain magnetic resonance imaging, 28 (45%) exhibited an acute brain lesion compared with 19 of the 69 (28%) of those randomized to a transseptal puncture ( P =0.036). No differences in clinically manifest complications or procedural efficacy were observed. More patients in the retrograde aortic arm were categorized as having a high likelihood of cognitive impairment at 6 months (33% compared with 19% of those in the transseptal arm), but substantial loss to follow-up was present. CONCLUSIONS: Among patients undergoing left ventricular catheter ablation procedures, a transseptal approach reduced the risk of acute brain lesions by nearly half compared with a retrograde aortic approach without sacrificing safety or efficacy. Given a likely embolic pathogenesis, the brain magnetic resonance imaging findings may reflect a propensity to other organ damage; these findings may extend to other procedures requiring left ventricular entry. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03946072.
Abstract 12679: Thirty-Day Readmissions for Recurrent Ventricular Tachycardia Following Catheter Ablation of Ventricular Tachycardia: Predictors and Outcomes
Ang, Qi Xuan , Deshmukh, Abhishek , Scott, Luis R. , Hussein, Ayman A. , Sroubek, Jakub , Wazni, Oussama M. , Tan, Min Choon , Yeo, Yong Hao , Santangeli, Pasquale , Lee, Justin

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.12679 Get It

Background: Despite the optimal efficacy of catheter ablation for ventricular tachycardia (VT), recurrence of VT can occur post-procedurally. However, data on the high-risk population for VT recurrence and the in-hospital outcomes remain scarce. Objective: This study aimed to determine the predictors of 30-day readmission for recurrent VT after catheter ablation of VT and assess the in-hospital outcomes. Method: Using the all-payer, nationally representative Nationwide Readmissions Database, we identified the patients aged ≥18 years who underwent catheter ablation for VT and were readmitted within 30 days because of recurrent VT from 2017 to 2020. We performed unweighted univariable and multivariable analyses to determine the outcomes and to identify the patient and hospital variables that were predictive of 30-day readmissions for recurrent VT. A p-value of <0.05 is considered statistically significant. Results: In our analysis, a total of 4,102 patients were discharged alive after VT ablation, of which 278 (6.8%) were readmitted within 30 days for recurrent VT. Recurrent VT was also the most common cause of 30-day readmission (47.7%, n=278/583). Compared to non-recurrent VT readmission, readmission due to recurrent VT had higher mortality during rehospitalization (7.55% vs 3.72%, p<0.01) and higher cumulative hospitalization cost ($57584 vs $37846, p<0.01). Via multivariable analysis, congestive heart failure (aOR: 1.84; 95% CI: 1.07-3.17; P=0.03) and non-elective index admissions (aOR: 1.88; 95% CI: 1.32-2.68; P<0.01) were the independent predictors of 30-day readmission for recurrent VT. Conclusion: Recurrent VT was the most common cause of 30-day readmission following VT ablation. Congestive heart failure and non-elective index admissions were the independent predictors of 30-day readmissions for recurrent VT. These highlight the importance of further research in ablation strategies to improve the efficacy of VT ablation.
Abstract 14310: Patient Reported Outcomes of Catheter Ablation for Atrial Fibrillation in Patients With Chronic Kidney Disease
Amin, Mustapha, Farwati, Amr , Turkmani, Mustafa , Nakagawa, Hiroshi , Tarakji, Khaldoun G. , Diab, Mohamed , Kanj, Mohamed , Dresing, Thomas , Bhargava, Mandeep , Baranowski, Bryan, Rickard, John , Cantillon, Daniel J. , Tchou, Patrick , Wazni, Oussama M. , Hussein, Ayman A. , Turkmani, Mustafa , Farwati, Medhat , Johnson, Brett, Saliba, Walid I. , Kuroda, Shunsuke , Callahan, Thomas D

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.14310 Get It

Introduction: Increasingly, catheter ablation for atrial fibrillation (AF) has been utilized for rhythm control and to improve quality of life (QoL). Data are limited on patient-centered ablation outcomes in individuals with chronic kidney disease (CKD). Objective: To examine clinical outcomes and QoL following AF ablation in CKD patients from a large patient-reported outcomes (PRO) database. Methods: All patients undergoing AF ablation (2013-2016) at our center were enrolled and assessed for outcomes using automated PRO surveys (baseline, 3 and 6 months after ablation, every 6 months thereafter). This analysis captured data at 1- and 3-year follow-up. CKD was defined as estimated glomerular filtration rate (eGFR) <60 ml/min using the 2021 CKD-EPI equation. The atrial fibrillation symptom severity scale (AFSSS) was used as the main measure for QoL assessment. In addition, data were collected on clinical improvement by patient report, AF burden, and healthcare utilization. Results: A total of 488 patients were identified (66% male, mean age 68.5, 56.2% persistent AF). QoL was significantly improved from baseline median (IQR) AFSSS of 14 (6-19.5) to 3 (0-9) at 1-year and 4 (0-9.5) at 3-year; P≤0.0001 for both. About 90% of patients reported improvement in their overall AF-related symptoms both at 1- and 3-year follow up. The proportion of patients in AF at the time of completion of the baseline survey was 51.2%, and this decreased to 6.2% at 1-year and 9.7% at 3-year follow up (P<0.0001 for both). AF burden was significantly reduced at 1-year and 3-year including frequency and duration of episodes (P<0.05 for both), with associated decrease in ER visits and hospitalizations; P<0.0001 for all comparisons. The proportion of patients on antiarrhythmics decreased from 61.8% at baseline to 35.6% and 22.7% at 1-year and 3-year, respectively (P<0.0001 for both). Conclusions: In a large AF-specific PRO system, catheter ablation for AF was associated with a significant improvement of QoL in most patients with CKD; with a decrease in AF burden and healthcare utilization.
Two‐Year Outcomes With a Next‐Generation Left Atrial Appendage Device: Final Results of the PINNACLE FLX Trial
Doshi, Shephal K. , Kar, Saibal , Sadhu, Ashish, Horton, Rodney , Osorio, José , Ellis, Christopher R. , Stone, James, Shah, Manish H. , Dukkipati, Srinivas R. , Adler, Stuart W., Kim, Jamie , Wazni, Oussama M. , Holmes, David R. , Shipley, Robert D., Christen, Thomas, Allocco, Dominic J. , Buchbinder, Maurice , Chinitz, Larry A. , Desai, Amish J., Dukkipatti, Srinivas R., Ellis, Christopher, Gibson, Douglas , Huber, Kenneth, Khairallah, Farhat, Koneru, Jayanthi N. , Mahoney, Paul G. , Mansour, Moussa , Mark, George E., Nicholson, William , REISS, J. A., Shehata, Michael , Swarup, Vijendra, Huber, Kurt , Téllez-Plaza, María , Ellis, Christopher , Shah, Manish , Nair, Devi G , Wazni, Oussama , Price, Matthew J , Holmes, David R , Reddy, Vivek Y , Kar, Saibal , Huber, Kurt , Price, Matthew J. , Reddy, Vivek Y. , DeLurgio, David B. , Ellis, Christopher, Huber, Kenneth, Mahoney, Paul, O’Neill, William W. , Reiss, James, Saliba, Walid I.

Journal of the American Heart Association | February 21, 2023 | Volume: 12 | Issue: 4 | Pages: No page available

10.1161/jaha.122.026295 Get It

Background The PINNACLE FLX (Protection Against Embolism for Non‐valvular AF [Atrial Fibrillation] Patients: Investigational Device Evaluation of the Watchman FLX LAA [Left Atrial Appendage] Closure Technology) trial evaluated the safety and efficacy of a next‐generation left atrial appendage closure device (WATCHMAN FLX; Boston Scientific, Marlborough, MA). At 1 year, the study met the primary end points of safety and anatomical efficacy/appendage closure. This final report of the PINNACLE FLX trial includes the prespecified secondary end point of ischemic stroke or systemic embolism at 2 years, also making it the first report of 2‐year outcomes with this next‐generation left atrial appendage closure device. Methods and Results Patients with nonvalvular atrial fibrillation with CHA 2 DS 2 ‐VASc score ≥2 (men) or ≥3 (women), with an appropriate rationale for left atrial appendage closure, were enrolled to receive the left atrial appendage closure device at 29 US centers. Adverse events were assessed by an independent clinical events committee, and imaging was assessed by independent core laboratories. Among 395 implanted patients (36% women; mean age, 74 years; CHA 2 DS 2 ‐VASc, 4.2±1.5), the secondary efficacy end point of 2‐year ischemic stroke or systemic embolism was met, with an absolute rate of 3.4% (annualized rate, 1.7%) and an upper 1‐sided 95% confidence bound of 5.3%, which was superior to the 8.7% performance goal. Two‐year rates of adverse events were as follows: 9.3% all‐cause mortality, 5.5% cardiovascular death, 3.4% all stroke, and 10.1% major bleeding (Bleeding Academic Research Consortium 3 or 5). There were no additional systemic embolisms, device embolizations, pericardial effusions, or symptomatic device‐related thrombi after 1 year. Conclusions The secondary end point of 2‐year stroke or systemic embolism was met at 3.4%. In these final results of the PINNACLE FLX trial, the next‐generation WATCHMAN FLX device demonstrated favorable safety and efficacy outcomes.
Cyclic Variation of Spectral Parameters for the Differentiation of Atrial Myocardium Before and Immediately Following Radiofrequency Ablation
Anjewierden, Scott , Wazni, Oussama M. , Vince, D. Geoffrey, Kanj, Mohamed , Fedewa, Russell J. , Saliba, Walid I.

Ultrasonic Imaging | September 13, 2021 | Volume: 43 | Issue: 6 | Pages: 299-307

10.1177/01617346211046314 Get It

Radiofrequency ablation (RFA) is a common treatment of atrial fibrillation. However, current treatment is associated with a greater than 20% recurrence rate, in part due to inadequate monitoring of tissue viability during ablation. Spectral parameters, in particular cyclic variation of integrated backscatter (CVIB), have shown promise as early indicators of myocardial recovery from ischemia. Our aim was to demonstrate the use of spectral parameters to differentiate atrial myocardium before and after radiofrequency ablation. An AcuNav 10 F catheter was used to collect radiofrequency signals from the posterior wall of the left atrium of patients before and immediately after RFA for AF. The normalized power spectrum was obtained and three spectral parameters (integrated backscatter [IB], slope, and intercept) were extracted across two continuous heart cycles. Parameters were gated for ventricular end-diastole and compared before and after ablation. Additionally, the cyclic variation of each of these three parameters was generated as an average of the variation across the two recorded heart cycles. Data from 14 patients before and after ablation demonstrated a significant difference in the magnitude of the cyclic variation of integrated backscatter (9.0 vs. 6.0 dB, p < .001) and cyclic variation of the intercept (14.0 vs. 11.5 dB, p = .04). No significant difference was noted in the magnitude of the cyclic variation of the slope. Among spectral parameters gated for end-diastole, significant differences were noted in the slope (−4.39 vs. −3.73 dB/MHz, p = .002) and intercept (16.8 vs. 11.9 dB, p = .002). No significant difference was noted in the integrated backscatter. Spectral parameters are able to differentiate atrial myocardium before and immediately following ablation and may be useful in monitoring atrial ablations.
Super and Nonresponders to Catheter Ablation for Atrial Fibrillation: A Quality-of-Life Assessment Using Patient Reported Outcomes
Farwati, Medhat , Wazni, Oussama M. , Tarakji, Khaldoun G. , Diab, Mohamed , Scandinaro, Anna , Amin, Mustapha, Zmaili, Mohammad , Bazarbashi, Najdat , Dikilitas, Ozan , Nakagawa, Hiroshi , Kanj, Mohamed , Dresing, Thomas , Bhargava, Mandeep , Baranowski, Bryan, Rickard, John , Cantillon, Daniel J. , Tchou, Patrick , Hussein, Ayman A. , Dikilitas, Ozan , Kuroda, Shunsuke , Callahan, Thomas D , Saliba, Walid I.

Circulation: Arrhythmia and Electrophysiology | July 19, 2021 | Volume: 14 | Issue: 8 | Pages: No page available

10.1161/circep.121.009938 Get It

Background: Atrial fibrillation (AF) ablation targets improvement in quality of life (QoL). Data is scarce on predictors of QoL improvement following ablation. We aimed to investigate the clinical characteristics underlying differential response in QoL after AF ablation (with or without arrhythmia recurrence). Methods: All patients undergoing AF ablation (2013–2016) at our center were prospectively enrolled in a fully automated patient-reported outcomes registry. A large number of variables were collected including AF symptom severity scale and AF burden (as indicated by AF frequency and duration scores). Patients were divided into 3 groups based on self-report of QoL improvement: remarkable (super responders), mild/moderate, and unchanged or worse (nonresponders). Univariable and multivariable logistic regression models assessed clinical characteristics and QoL outcomes. Results: A total of 956 patients were included (25% females, mean age 63.9). Most patients (≈80%) were super responders (n=761), 138 (14.4%) had mild/moderate improvement, and 57 (5.9%) were nonresponders. The strongest predictors of remarkable QoL improvement were freedom of arrhythmia recurrence (OR, 2.42 [95% CI, 1.27–4.59], P =0.007) and lower AF burden at 12 months. Similarly, higher AF burden was significantly associated with clinical nonresponse. In patients with observed clinical recurrence-QoL mismatch, changes in AF burden at 12 months were the main predictors of QoL outcome, with lower burden predicting higher improvement in QoL and vice versa. Conclusions: Most patients derive significant QoL benefit from AF ablation. Freedom from arrhythmia recurrence and lower AF burden predict remarkable QoL improvement following ablation.
Primary Outcome Evaluation of a Next-Generation Left Atrial Appendage Closure Device
Kar, Saibal , Doshi, Shephal K. , Sadhu, Ashish, Horton, Rodney , Osorio, José , Stone, James, Shah, Manish H. , Dukkipati, Srinivas R. , Adler, Stuart W., Kim, Jamie , Wazni, Oussama M. , Price, Mathew J., Holmes, David R. , Shipley, Robert D., Gordon, Nicole, Allocco, Dominic J. , Investigators, On behalf of the PINNACLE FLX, Kar, Saibal , Ellis, Christopher R. , Nair, Devi G , Asch, Federico M. , Reddy, Vivek Y. , Investigators, On behalf of the PINNACLE FLX

Circulation | April 6, 2021 | Volume: 143 | Issue: 18 | Pages: 1754-1762

10.1161/circulationaha.120.050117 Get It

Background: Left atrial appendage (LAA) occlusion provides an alternative to oral anticoagulation for thromboembolic risk reduction in patients with nonvalvular atrial fibrillation. Since regulatory approval in 2015, the WATCHMAN device has been the only LAA closure device available for clinical use in the United States. The PINNACLE FLX study (Protection Against Embolism for Nonvalvular AF Patients: Investigational Device Evaluation of the Watchman FLX LAA Closure Technology) evaluated the safety and effectiveness of the next-generation WATCHMAN FLX LAA closure device in patients with nonvalvular atrial fibrillation in whom oral anticoagulation is indicated, but who have an appropriate rationale to seek a nonpharmaceutical alternative. Methods: This was a prospective, nonrandomized, multicenter US Food and Drug Administration study. The primary safety end point was the occurrence of one of the following events within 7 days after the procedure or by hospital discharge, whichever was later: death, ischemic stroke, systemic embolism, or device- or procedure-related events requiring cardiac surgery. The primary effectiveness end point was the incidence of effective LAA closure (peri-device flow ≤5 mm), as assessed by the echocardiography core laboratory at 12-month follow-up. Results: A total of 400 patients were enrolled. The mean age was 73.8±8.6 years and the mean CHA 2 DS 2 -VASc score was 4.2±1.5. The incidence of the primary safety end point was 0.5% with a 1-sided 95% upper CI of 1.6%, meeting the performance goal of 4.2% ( P <0.0001). The incidence of the primary effectiveness end point was 100%, with a 1-sided 95% lower CI of 99.1%, again meeting the performance goal of 97.0% ( P <0.0001). Device-related thrombus was reported in 7 patients, no patients experienced pericardial effusion requiring open cardiac surgery, and there were no device embolizations. Conclusions: LAA closure with this next-generation LAA closure device was associated with a low incidence of adverse events and a high incidence of anatomic closure. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02702271.