Abstract Objective: The National Institutes of Health (NIH) Executive Abilities: Measures and Instruments for Neurobehavioral Evaluation and Research (EXAMINER) is a validated laptop-based battery of executive functioning tests. A modified tablet version of the EXAMINER was developed on the UCSF Tablet-based Cognitive Assessment Tool (TabCAT-EXAMINER). Here we describe the battery and investigate the reliability and validity of a composite score. Methods: A diagnostically heterogeneous sample of 2135 individuals (mean age = 65.58, SD = 16.07), including controls and participants with a variety of neurodegenerative syndromes, completed the TabCAT-EXAMINER. A composite score was developed using confirmatory factor analysis and item response theory. Validity was evaluated via linear regressions that tested associations with neuropsychological tests, demographics, clinical diagnosis, and disease severity. Replicability of cross-sectional results was tested in a separate sample of participants ( n = 342) recruited from a frontotemporal dementia study. As this separate sample also collected longitudinal TabCAT-EXAMINER measures, we additionally assessed test-retest reliability and associations between baseline disease severity and changes in TabCAT-EXAMINER scores. Results: The TabCAT-EXAMINER score was normally distributed, demonstrated high test-retest reliability, and was associated in the expected directions with independent tests of executive functioning, demographics, disease severity, and diagnosis. Greater baseline disease severity was associated with more rapid longitudinal TabCAT-EXAMINER decline. Conclusions: The TabCAT-EXAMINER is a tablet-based executive functioning battery developed for observational research and clinical trials. Performance can be summarized as a single composite score, and results of this study support its reliability and validity in cognitive aging and neurodegenerative disease cohorts.
Left Ventricular Entry to Reduce Brain Lesions During Catheter Ablation: A Randomized Trial
BACKGROUND: Catheter ablation of ventricular arrhythmias, one of the most rapidly growing procedures in cardiac electrophysiology, is associated with magnetic resonance imaging–detected brain lesions in more than half of cases. Although a retrograde aortic approach is conventional, modern tools enable entry through a transseptal approach that may avoid embolization of debris from the arterial system. We sought to test the hypothesis that a transseptal puncture would mitigate brain injury compared with a retrograde aortic approach. METHODS: The TRAVERSE trial (Transseptal Versus Retrograde Aortic Ventricular Entry to Reduce Systemic Emboli) was a multicenter randomized controlled comparative effectiveness trial. Patients with left ventricular arrhythmias undergoing catheter ablation procedures were randomly assigned to a transseptal puncture approach compared (1:1) with a retrograde aortic approach. The primary outcome was the presence of an acute brain lesion detected by magnetic resonance imaging. Secondary outcomes included clinically manifest complications, procedural efficacy, and 6-month neurocognitive assessments. RESULTS: Among the 62 patients randomly assigned to a retrograde aortic approach with postoperative brain magnetic resonance imaging, 28 (45%) exhibited an acute brain lesion compared with 19 of the 69 (28%) of those randomized to a transseptal puncture ( P =0.036). No differences in clinically manifest complications or procedural efficacy were observed. More patients in the retrograde aortic arm were categorized as having a high likelihood of cognitive impairment at 6 months (33% compared with 19% of those in the transseptal arm), but substantial loss to follow-up was present. CONCLUSIONS: Among patients undergoing left ventricular catheter ablation procedures, a transseptal approach reduced the risk of acute brain lesions by nearly half compared with a retrograde aortic approach without sacrificing safety or efficacy. Given a likely embolic pathogenesis, the brain magnetic resonance imaging findings may reflect a propensity to other organ damage; these findings may extend to other procedures requiring left ventricular entry. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03946072.