BACKGROUND: Catheter ablation of ventricular arrhythmias, one of the most rapidly growing procedures in cardiac electrophysiology, is associated with magnetic resonance imaging–detected brain lesions in more than half of cases. Although a retrograde aortic approach is conventional, modern tools enable entry through a transseptal approach that may avoid embolization of debris from the arterial system. We sought to test the hypothesis that a transseptal puncture would mitigate brain injury compared with a retrograde aortic approach. METHODS: The TRAVERSE trial (Transseptal Versus Retrograde Aortic Ventricular Entry to Reduce Systemic Emboli) was a multicenter randomized controlled comparative effectiveness trial. Patients with left ventricular arrhythmias undergoing catheter ablation procedures were randomly assigned to a transseptal puncture approach compared (1:1) with a retrograde aortic approach. The primary outcome was the presence of an acute brain lesion detected by magnetic resonance imaging. Secondary outcomes included clinically manifest complications, procedural efficacy, and 6-month neurocognitive assessments. RESULTS: Among the 62 patients randomly assigned to a retrograde aortic approach with postoperative brain magnetic resonance imaging, 28 (45%) exhibited an acute brain lesion compared with 19 of the 69 (28%) of those randomized to a transseptal puncture ( P =0.036). No differences in clinically manifest complications or procedural efficacy were observed. More patients in the retrograde aortic arm were categorized as having a high likelihood of cognitive impairment at 6 months (33% compared with 19% of those in the transseptal arm), but substantial loss to follow-up was present. CONCLUSIONS: Among patients undergoing left ventricular catheter ablation procedures, a transseptal approach reduced the risk of acute brain lesions by nearly half compared with a retrograde aortic approach without sacrificing safety or efficacy. Given a likely embolic pathogenesis, the brain magnetic resonance imaging findings may reflect a propensity to other organ damage; these findings may extend to other procedures requiring left ventricular entry. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03946072.
Anatomical location of leadless pacemaker and the risk of pacing‐induced cardiomyopathy
Abstract Background It is unclear if the location of implantation of the leadless pacemaker (LP) makes a difference in the incidence of pacing‐induced cardiomyopathy (PICM). Aim The aim of this study was to compare the incidence of PICM based on the location of implantation of LP. Methods A total of 358 consecutive patients [women: 171 (48%), mean age: 73 ± 15 years] with left ventricular ejection fraction (EF) > 50%, who received an LP (Micra) between January 2017 and June 2022, formed the study cohort. Micra‐AV and Micra‐VR were implanted in 122 (34%) and 236 (66%) patients, respectively. Fluoroscopically, the location of implantation of LP in the interventricular septum (IS) was divided into two equal halves (apex/apical septum [AS] and mid/high septum [HS]). During follow‐up, PICM was defined as an EF drop of ≥10%. Results LP was implanted in 109 (34%) and 249 (66%) patients at AS and HS locations, respectively. During a mean 18 ± 8 months follow‐up, 28 patients (7.8%) developed PICM. Among the 249 patients with HS placement of LP, 10 (4%) developed PICM, whereas among the 109 patients with AS placement of LP, 18 (16.5%) developed PICM ( p = .002). AS location was associated with a higher risk of PICM compared to HS locations (adjusted hazard ratio: 4.42, p < .001). Conclusion AS location of LP was associated with a higher risk of PICM compared to HS placement. Larger randomized studies are needed to confirm our findings.