BACKGROUND: Catheter ablation of ventricular arrhythmias, one of the most rapidly growing procedures in cardiac electrophysiology, is associated with magnetic resonance imaging–detected brain lesions in more than half of cases. Although a retrograde aortic approach is conventional, modern tools enable entry through a transseptal approach that may avoid embolization of debris from the arterial system. We sought to test the hypothesis that a transseptal puncture would mitigate brain injury compared with a retrograde aortic approach. METHODS: The TRAVERSE trial (Transseptal Versus Retrograde Aortic Ventricular Entry to Reduce Systemic Emboli) was a multicenter randomized controlled comparative effectiveness trial. Patients with left ventricular arrhythmias undergoing catheter ablation procedures were randomly assigned to a transseptal puncture approach compared (1:1) with a retrograde aortic approach. The primary outcome was the presence of an acute brain lesion detected by magnetic resonance imaging. Secondary outcomes included clinically manifest complications, procedural efficacy, and 6-month neurocognitive assessments. RESULTS: Among the 62 patients randomly assigned to a retrograde aortic approach with postoperative brain magnetic resonance imaging, 28 (45%) exhibited an acute brain lesion compared with 19 of the 69 (28%) of those randomized to a transseptal puncture ( P =0.036). No differences in clinically manifest complications or procedural efficacy were observed. More patients in the retrograde aortic arm were categorized as having a high likelihood of cognitive impairment at 6 months (33% compared with 19% of those in the transseptal arm), but substantial loss to follow-up was present. CONCLUSIONS: Among patients undergoing left ventricular catheter ablation procedures, a transseptal approach reduced the risk of acute brain lesions by nearly half compared with a retrograde aortic approach without sacrificing safety or efficacy. Given a likely embolic pathogenesis, the brain magnetic resonance imaging findings may reflect a propensity to other organ damage; these findings may extend to other procedures requiring left ventricular entry. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03946072.
Automated Vulnerability Testing Identifies Patients With Inadequate Defibrillation Safety Margin
Background— Implantable cardioverter-defibrillator system efficacy is tested at implant by induction of ventricular fibrillation (VF). Defibrillation safety margin can be assessed without VF induction using upper limit of vulnerability methods, but these methods have required manual determination of T-wave timing. Methods and Results— To test the feasibility of an inductionless system of implant testing, a multicenter prospective study of an automated vulnerability safety margin system was conducted, which measured T-wave timing using an intracardiac electrogram during a ventricular pacing train. The system delivered up to 4 T-wave shocks of 18 J. Lack of VF induction by all 4 shocks was considered evidence of defibrillation adequacy. Patients subsequently underwent conventional defibrillation testing to meet a standard implant criterion. The 95% lower CI for defibrillation success at 25 J for noninduced patients was found using Bayesian statistics. Sixty patients were enrolled at 6 centers. Vulnerability testing and defibrillation success results were obtained from 54 patients. Vulnerability testing induced VF in 10 (19%) patients, of whom 2 required system revision. All patients not induced by vulnerability testing were successfully defibrillated twice at ≤25 J. The Bayesian credible interval was 97% to 100% for the population success rate of defibrillation at 25 J for automated vulnerability safety margin noninduced patients. Conclusions— An automated system identified all patients who failed conventional safety margin testing, while inducing only 19% of patients. Although limited by sample size, this study suggests the feasibility of automated implant testing that substantially reduces the need for VF induction in patients receiving implantable cardioverter-defibrillators.