BACKGROUND: Recent randomized trials have demonstrated that for patients with severe tricuspid regurgitation (TR), transcatheter tricuspid valve interventions (TTVI) improve patients’ symptoms, function, and quality of life and that the amount of health status improvement correlates with the extent of TR reduction. Defining this relationship in greater detail can potentially provide insight into device selection and patient-specific treatment goals. We therefore sought to better understand the relationship between both baseline TR severity and change in TR after TTVI and the extent of improvement in health status after TTVI. METHODS: As part of the Tri-QOL (Kansas City Cardiomyopathy Questionnaire Validation in Tricuspid Valve Disease) study, data from 11 studies of TTVI devices were transferred to the US Food and Drug Administration to harmonize and anonymize before analysis by an independent center. This secondary, observational analysis used patient-level data from the 6 single-arm studies of patients who underwent TTVI to explore the association of change in KCCQ-OS with TR grade using multivariable models, adjusted for age, sex, chronic lung disease, and baseline KCCQ-OS. The primary model included TR grade at baseline, TR grade at 1 month, and the interaction between the two. RESULTS: Among 1056 patients with ≥severe TR who underwent TTVI, mean age was 79.1±7.1 years, 60.3% were female, and mean baseline Kansas City Cardiomyopathy Questionnaire-overall summary score [KCCQ-OS] was 49.5±22.3. Baseline TR grade was severe in 33.5%, massive in 35.9%, and torrential in 30.6%. One-month after TTVI, TR was none/trace in 21.7%, mild in 27.2%, moderate in 28.1%, and ≥evere in 23.1%, while the mean change in KCCQ-OS was 17.0±21.3 points. In a multivariable model that included TR grade at baseline, TR grade at 1 month, and their interaction, there was a strong association between reduction in TR and improvement in KCCQ-OS, with no consistent evidence of a threshold of TR grade below which there was no further improvement in KCCQ-OS. However, among patients with baseline torrential TR, the extent of health status improvement plateaued for patients achieving moderate or less TR at 1 month (ie, a 3-grade improvement from baseline). CONCLUSIONS: Health status improvement after TTVI was most strongly associated with the degree of TR reduction, although there was minimal additional improvement for most patients beyond a 3-grade reduction in TR. These findings support the goal of achieving mild or less TR with TTVI, although patients with torrential TR at baseline may be well served if moderate TR can be achieved.
Two‐Year Outcomes With a Next‐Generation Left Atrial Appendage Device: Final Results of the PINNACLE FLX Trial
Background The PINNACLE FLX (Protection Against Embolism for Non‐valvular AF [Atrial Fibrillation] Patients: Investigational Device Evaluation of the Watchman FLX LAA [Left Atrial Appendage] Closure Technology) trial evaluated the safety and efficacy of a next‐generation left atrial appendage closure device (WATCHMAN FLX; Boston Scientific, Marlborough, MA). At 1 year, the study met the primary end points of safety and anatomical efficacy/appendage closure. This final report of the PINNACLE FLX trial includes the prespecified secondary end point of ischemic stroke or systemic embolism at 2 years, also making it the first report of 2‐year outcomes with this next‐generation left atrial appendage closure device. Methods and Results Patients with nonvalvular atrial fibrillation with CHA 2 DS 2 ‐VASc score ≥2 (men) or ≥3 (women), with an appropriate rationale for left atrial appendage closure, were enrolled to receive the left atrial appendage closure device at 29 US centers. Adverse events were assessed by an independent clinical events committee, and imaging was assessed by independent core laboratories. Among 395 implanted patients (36% women; mean age, 74 years; CHA 2 DS 2 ‐VASc, 4.2±1.5), the secondary efficacy end point of 2‐year ischemic stroke or systemic embolism was met, with an absolute rate of 3.4% (annualized rate, 1.7%) and an upper 1‐sided 95% confidence bound of 5.3%, which was superior to the 8.7% performance goal. Two‐year rates of adverse events were as follows: 9.3% all‐cause mortality, 5.5% cardiovascular death, 3.4% all stroke, and 10.1% major bleeding (Bleeding Academic Research Consortium 3 or 5). There were no additional systemic embolisms, device embolizations, pericardial effusions, or symptomatic device‐related thrombi after 1 year. Conclusions The secondary end point of 2‐year stroke or systemic embolism was met at 3.4%. In these final results of the PINNACLE FLX trial, the next‐generation WATCHMAN FLX device demonstrated favorable safety and efficacy outcomes.
Letter by Natale et al Regarding Article, “Amplatzer Amulet Left Atrial Appendage Occluder Versus Watchman Device for Stroke Prophylaxis (Amulet IDE): A Randomized, Controlled Trial”
Relationship Between Residual Mitral Regurgitation and Clinical and Quality-of-Life Outcomes After Transcatheter and Medical Treatments in Heart Failure
Background: In the randomized COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation), among 614 patients with heart failure with 3+ or 4+ secondary mitral regurgitation (MR), transcatheter mitral valve repair (TMVr) with the MitraClip reduced MR, heart failure hospitalizations, and mortality and improved quality of life compared with guideline-directed medical therapy (GDMT) alone. We aimed to examine the prognostic relationship between MR reduction and outcomes after TMVr and GDMT alone. Methods: Outcomes in COAPT between 30 days and 2 years were examined on the basis of the severity of residual MR at 30 days. Results: TMVr-treated patients had less severe residual MR at 30 days than GDMT-treated patients (0/1+, 2+, and 3+/4+: 72.9%, 19.9%, and 7.2% versus 8.2%, 26.1%, and 65.8%, respectively [ P <0.0001]). The rate of composite death or heart failure hospitalizations between 30 days and 2 years was lower in patients with 30-day residual MR of 0/1+ and 2+ compared with patients with 30-day residual MR of 3+/4+ (37.7% versus 49.5% versus 72.2%, respectively [ P <0.0001]). This relationship was consistent in the TMVr and GDMT arms ( P interaction =0.92). The improvement in Kansas City Cardiomyopathy Questionnaire score from baseline to 30 days was maintained between 30 days and 2 years in patients with 30-day MR ≤2+ but deteriorated in those with 30-day MR 3+/4+ (–0.3±1.7 versus –9.4±4.6 [ P =0.0008]) consistently in both groups ( P interaction =0.95). Conclusions: In the COAPT trial, reduced MR at 30 days was associated with greater freedom from death or heart failure hospitalizations and improved quality of life through 2-year follow-up whether the MR reduction was achieved by TMVr or GDMT. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01626079.
Primary Outcome Evaluation of a Next-Generation Left Atrial Appendage Closure Device
Background: Left atrial appendage (LAA) occlusion provides an alternative to oral anticoagulation for thromboembolic risk reduction in patients with nonvalvular atrial fibrillation. Since regulatory approval in 2015, the WATCHMAN device has been the only LAA closure device available for clinical use in the United States. The PINNACLE FLX study (Protection Against Embolism for Nonvalvular AF Patients: Investigational Device Evaluation of the Watchman FLX LAA Closure Technology) evaluated the safety and effectiveness of the next-generation WATCHMAN FLX LAA closure device in patients with nonvalvular atrial fibrillation in whom oral anticoagulation is indicated, but who have an appropriate rationale to seek a nonpharmaceutical alternative. Methods: This was a prospective, nonrandomized, multicenter US Food and Drug Administration study. The primary safety end point was the occurrence of one of the following events within 7 days after the procedure or by hospital discharge, whichever was later: death, ischemic stroke, systemic embolism, or device- or procedure-related events requiring cardiac surgery. The primary effectiveness end point was the incidence of effective LAA closure (peri-device flow ≤5 mm), as assessed by the echocardiography core laboratory at 12-month follow-up. Results: A total of 400 patients were enrolled. The mean age was 73.8±8.6 years and the mean CHA 2 DS 2 -VASc score was 4.2±1.5. The incidence of the primary safety end point was 0.5% with a 1-sided 95% upper CI of 1.6%, meeting the performance goal of 4.2% ( P <0.0001). The incidence of the primary effectiveness end point was 100%, with a 1-sided 95% lower CI of 99.1%, again meeting the performance goal of 97.0% ( P <0.0001). Device-related thrombus was reported in 7 patients, no patients experienced pericardial effusion requiring open cardiac surgery, and there were no device embolizations. Conclusions: LAA closure with this next-generation LAA closure device was associated with a low incidence of adverse events and a high incidence of anatomic closure. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02702271.