Back to Authors

Calkins, Hugh

0000-0002-9262-9433

Mayo Clinic

Johns Hopkins University

Citations 4

Implantable cardioverter defibrillator use in arrhythmogenic right ventricular cardiomyopathy in North America and Europe
Carrick, Richard , Marco, Corrado De , Gasperetti, Alessio , Bosman, Laurens P. , Trancuccio, Alessandro , Mazzanti, Andrea , Murray, Brittney , Pendleton, Catherine, Tichnell, Crystal , Tandri, Harikrishna , Zeppenfeld, Katja , Wilde, Arthur A.M. , Davies, Brianna , Seifer, Colette , Roberts, Jason D. , MacIntyre, Ciorsti, Alqarawi, Wael , Cutler, Michael J. , Targetti, Mattia , Calò, Leonardo , Vitali, Francesco , Compagnucci, Paolo , Cappelletto, Chiara, Duru, Fırat , Jensen, Henrik Kjærulf , Svensson, Anneli , Dahlberg, Pia , Hasselberg, Nina E. , Marco, Andrea Di , Jordà, Paloma , Weidmann, Zoraida Moreno , Borowiec, Karolina , Delinière, Antoine , Tintelen, J. Peter van , Olivotto, Iacopo , Saguner, Ardan M. , Cox, Moniek G.P.J. , Merlo, Marco , Riele, Anneline S.J.M. te , Wu, Kathérine C. , Calkins, Hugh , James, Cynthia A. , Cadrin‐Tourigny, Julia , Carrick, Richard T , De Marco, Corrado , Gourraud, Jean-Baptiste , Trancuccio, Alessandro , Mazzanti, Andrea , Murray, Brittney , Zeppenfeld, Katja , Davies, Brianna , Alqarawi, Wael , Bertini, Matteo , Compagnucci, Paolo , Cappelletto, Chiara , Stolfo, Davide , Duru, Firat , Di Marco, Andrea , Arbelo, Elena , Delinière, Antoine , Saguner, Ardan M , Merlo, Marco , Krahn, Andrew D , Te Riele, Anneline S J M , Calkins, Hugh , James, Cynthia A , Cadrin-Tourigny, Julia , van Tintelen, J Peter , Olivotto, Iacopo , Jensen, Henrik Kjærulf , Gourraud, Jean‐Baptiste , Healey, Jeff S. , Tadros, Rafik , Casella, Michela , Russo, Antonio Dello , Luca, Antonio De , Arbelo, Elena , Biernacka, Elżbieta Katarzyna , Platonov, Pyotr G. , Haugaa, Kristina H. , Tondo, Claudio , Krahn, Andrew D.

European Heart Journal | January 10, 2024 | Volume: 45 | Issue: 7 | Pages: 538-548

10.1093/eurheartj/ehad799 Get It

Abstract Background and Aims Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. Methods This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%–25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. Results One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. Conclusions North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.
Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial
Haines, David E. , Boersma, Lucas V.A. , Sood, Nitesh , Natale, Andrea , Marchlinski, Francis E. , Calkins, Hugh , Sanders, Prashanthan , Packer, Douglas L. , Kuck, Karl-Heinz , Hindricks, Gerhard , Önal, Birce , Cerkvenik, Jeffrey , Tada, Hiroshi , Investigators, on behalf of the PULSED AF, Verma, Atul , Boersma, Lucas , Natale, Andrea , Marchlinski, Francis E , Calkins, Hugh , Sanders, Prashanthan , Packer, Douglas L , Kuck, Karl-Heinz , Onal, Birce , Verma, Atul , DeLurgio, David B. , Investigators, on behalf of the PULSED AF

Circulation | March 6, 2023 | Volume: 147 | Issue: 19 | Pages: 1422-1432

10.1161/circulationaha.123.063988 Get It

Background: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. Methods: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. Results: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. Conclusions: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04198701.
Atrial Fibrillation and Dementia: A Report From the AF-SCREEN International Collaboration
Rivard, Léna , Friberg, Leif , Conen, David , Healey, Jeff S. , Berge, Trygve , Boriani, Giuseppe , Brandes, Axel , Calkins, Hugh , Camm, A. John , Espuny, Josep Lluis Clua , Collins, Ronan, Connolly, Stuart, Dagres, Nikolaos , Elkind, Mitchell S.V. , Engdahl, Johan, Field, Thalia S. , Glotzer, Taya V., Hankey, Graeme J. , Hills, Mellanie True , Johnson, Linda S.B. , Joung, Boyoung, Krieger, Derk, Løchen, Maja-Lisa, Madhavan, Malini, Mairesse, Georges H., Montaner, Joan , Rienstra, Michiel , Rosenqvist, Mårten, Sandhu, Roopinder K., Smyth, Breda, Stavrakis, Stavros , Gelder, Isabelle C. Van, Wang, Ji‐Guang , Freedman, Ben , Joung, Boyoung , Healey, Jeffrey S , Chen, Lin Y , Lluis Clua Espuny, Josep , Dagres, Nikolaos , Elkind, Mitchell S V , Field, Thalia S , Gersh, Bernard J , Hankey, Graeme J , Harbison, Joseph A , Haeusler, Karl G , True Hills, Mellanie , Johnson, Linda S B , Khairy, Paul , Kirchhof, Paulus , Lip, Gregory Y H , Montaner, Joan , Ntaios, George , Quinn, Terence J , Rienstra, Michiel , Schnabel, Renate B , Stavrakis, Stavros , Themistoclakis, Sakis , Wang, Ji-Guang , Freedman, Ben , Boriani, Giuseppe , Joung, Boyoung , Brandes, Axel , Rivard, Lena , Friberg, Leif , Conen, David , Berge, Trygve , Calkins, Hugh , Camm, Alan John , Collins, Ronan, Connolly, Stuart, Engdahl, Johan, Glotzer, Taya V., Krieger, Derk, Løchen, Maja-Lisa, Madhavan, Malini, Mairesse, Georges H., Rosenqvist, Mårten, Sandhu, Roopinder K., Smyth, Breda, Gelder, Isabelle C. Van

Circulation | January 31, 2022 | Volume: 145 | Issue: 5 | Pages: 392-409

10.1161/circulationaha.121.055018 Get It

Growing evidence suggests a consistent association between atrial fibrillation (AF) and cognitive impairment and dementia that is independent of clinical stroke. This report from the AF-SCREEN International Collaboration summarizes the evidence linking AF to cognitive impairment and dementia. It provides guidance on the investigation and management of dementia in patients with AF on the basis of best available evidence. The document also addresses suspected pathophysiologic mechanisms and identifies knowledge gaps for future research. Whereas AF and dementia share numerous risk factors, the association appears to be independent of these variables. Nevertheless, the evidence remains inconclusive regarding a direct causal effect. Several pathophysiologic mechanisms have been proposed, some of which are potentially amenable to early intervention, including cerebral microinfarction, AF-related cerebral hypoperfusion, inflammation, microhemorrhage, brain atrophy, and systemic atherosclerotic vascular disease. The mitigating role of oral anticoagulation in specific subgroups (eg, low stroke risk, short duration or silent AF, after successful AF ablation, or atrial cardiopathy) and the effect of rhythm versus rate control strategies remain unknown. Likewise, screening for AF (in cognitively normal or cognitively impaired patients) and screening for cognitive impairment in patients with AF are debated. The pathophysiology of dementia and therapeutic strategies to reduce cognitive impairment warrant further investigation in individuals with AF. Cognition should be evaluated in future AF studies and integrated with patient-specific outcome priorities and patient preferences. Further large-scale prospective studies and randomized trials are needed to establish whether AF is a risk factor for cognitive impairment, to investigate strategies to prevent dementia, and to determine whether screening for unknown AF followed by targeted therapy might prevent or reduce cognitive impairment and dementia.
First-in-Human Experience and Acute Procedural Outcomes Using a Novel Pulsed Field Ablation System: The PULSED AF Pilot Trial
Boersma, Lucas V.A. , Haines, David E., Natale, Andrea , Marchlinski, Francis E. , Sanders, Prashanthan , Calkins, Hugh , Packer, Douglas L. , Hummel, John D. , Önal, Birce , Rosen, Sofi, Kuck, Karl-Heinz , Hindricks, Gerhard, Wilsmore, Bradley , Verma, Atul , Boersma, Lucas , Natale, Andrea , Marchlinski, Francis E , Sanders, Prashanthan , Calkins, Hugh , Packer, Douglas L , Hummel, John , Onal, Birce , Kuck, Karl-Heinz , Wilsmore, Bradley , Haines, David E., Rosen, Sofi, Hindricks, Gerhard

Circulation: Arrhythmia and Electrophysiology | December 29, 2021 | Volume: 15 | Issue: 1 | Pages: No page available

10.1161/circep.121.010168 Get It

Background: Pulsed field ablation (PFA) is a novel form of ablation using electrical fields to ablate cardiac tissue. There are only limited data assessing the feasibility and safety of this type of ablation in humans. Methods: PULSED AF (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF; https://www.clinicaltrials.gov ; unique identifier: NCT04198701) is a nonrandomized, prospective, multicenter, global, premarket clinical study. The first-in-human pilot phase evaluated the feasibility and efficacy of pulmonary vein isolation using a novel PFA system delivering bipolar, biphasic electrical fields through a circular multielectrode array catheter (PulseSelect; Medtronic, Inc). Thirty-eight patients with paroxysmal or persistent atrial fibrillation were treated in 6 centers in Australia, Canada, the United States, and the Netherlands. The primary outcomes were ability to achieve acute pulmonary vein isolation intraprocedurally and safety at 30 days. Results: Acute electrical isolation was achieved in 100% of pulmonary veins (n=152) in the 38 patients. Skin-to-skin procedure time was 160±91 minutes, left atrial dwell time was 82±35 minutes, and fluoroscopy time was 28±9 minutes. No serious adverse events related to the PFA system occurred in the 30-day follow-up including phrenic nerve injury, esophageal injury, stroke, or death. Conclusions: In this first-in-human clinical study, 100% pulmonary vein isolation was achieved using only PFA with no PFA system–related serious adverse events. Graphic Abstract: A graphic abstract is available for this article.