Standardized endpoint definitions for trials of transcatheter left atrial appendage closure: a consensus from the Left Atrial Appendage Academic Research Consortium
Abstract Since its introduction in 2002, left atrial appendage closure (LAAC) has rapidly expanded as an alternative to anticoagulation in patients with atrial fibrillation at high risk of stroke. Harmonized processes for data collection, analysis, and reporting in LAAC trials are essential to enhance research quality and improve clinical practice. The Left Atrial Appendage Academic Research Consortium (LAARC) initiative is an independent collaboration of academic research organizations, cardiology and neurology experts, clinical trialists, and regulatory authorities from the USA, Europe, and Asia. The consortium engaged clinical experts, regulators—including the US Food and Drug Administration (FDA), European Notified Bodies, and Japan’s Pharmaceuticals and Medical Devices Agency (PMDA)—and industry leaders to define standardized study elements and endpoints for LAAC trials. Key considerations included alignment with prior Academic Research Consortium initiatives, procedural and mechanistic insights, and clinical relevance. Consensus definitions were proposed for mortality, stroke, bleeding, and device performance, along with composite endpoints for safety and effectiveness. The proposed LAARC consensus definitions aim to standardize endpoint reporting, improve comparability across studies, and support regulatory and clinical trial applications for this evolving therapy through broad dissemination in the peer-reviewed literature.
Left Atrial Appendage Closure or Anticoagulation for Atrial Fibrillation
Importance Left atrial appendage occlusion (LAAO) is used in patients with contraindications to oral anticoagulation, who are at increased risk for major bleeding (MB). Objective To evaluate the incidence, predictors, management, and clinical outcomes of MB after LAAO in the Amulet IDE trial. Design, Setting, and Participants The randomized clinical Amulet IDE trial enrolled patients from 2016 through 2019 with 5-year follow-up. Procedures were performed at specialized LAAO centers. Of 1878 randomized patients (1:1 Amulet vs Watchman), 1833 underwent attempted LAAO implantation. These data were analyzed from May 2025 through November 2025. Main Outcomes and Measures Pooled (Amulet and Watchman) patients with vs without MB (Bleeding Academic Research Consortium [BARC] score ≥3: overt bleeding with transfusion and ≥3 g/dL hemoglobin drop) were compared. Results This study included a total of 1833 patients (57.7% male and 42.3% female; mean [SD] age, 75.8 [7.5] years). MB occurred in 331 patients (18.1%) over 5 years (annualized rate 5.9% per year). Patients with MB were older (76.8 vs 74.7 years) and had higher CHA 2 DS 2 -VASc (4.8 vs 4.6) and HAS-BLED (3.4 vs 3.2) scores, as well as greater prevalence of diabetes (38.7% vs 34.1%), prior MB (45.3% vs 28.0%), and kidney disease (9.4% vs 4.5%). MB risk was highest in the first 6 months after LAAO (20.5% per year), then decreased to 3.9% per year through 5 years. Most MB events were nonprocedural (88.8%) with gastrointestinal bleeding accounting for 252 of 438 events. Independent predictors of MB included increasing age (hazard ratio [HR], 1.04; 95% CI, 1.02-1.06), female sex (HR, 1.25; 95% CI, 1.01-1.56), diabetes (HR, 1.26; 95% CI, 1.01-1.58), prior MB (HR, 1.93; 95% CI, 1.55-2.40), and kidney disease (HR, 2.15; 95% CI, 1.48, 3.12). At first MB event, 47.1% of patients were not receiving antithrombotic therapy and 92 patients had recurrent events. Patients with MB had significantly higher rates of the composite of stroke, systemic embolism, or cardiovascular death (32.5% vs 18.0%; P < .001), driven by higher stroke (14.7% vs 6.6%) and cardiovascular death (24.4% vs 12.9%) rates. All-cause mortality was also higher (49.2% vs 25.4%; P < .001). MB was fatal (BARC score of 5) in 25 patients (1.4%). Conclusions and Relevance In this study, MB was common in this high-risk population and largely related to underlying patient factors. Early MB risk was highest 6 months post-LAAO, then dropped considerably. Most events were gastrointestinal and occurred even in patients on minimal or no antithrombotic therapy. MB after LAAO was strongly associated with increased stroke and mortality. Trial Registration ClinicalTrials.gov Identifier: NCT02879448
Comparison of Flow Dynamics After Left Atrial Appendage Occlusion With the Watchman FLX Versus Amulet Devices: Implications for Device‐Related Thrombosis
ABSTRACT Background This study aims to assess how Watchman FLX (Boston Scientific) and Amplatzer Amulet (Abbott) devices for left atrial appendage occlusion (LAAO) impact the flow dynamics in the LA and the risk of device‐related thrombosis (DRT). Methods Flow simulations were carried out for 12 AF patients before and after undergoing LAAO. Six patients had Watchman FLX while the other six had Amulet devices, of which three in each group had DRT. The flow parameters investigated included the LA velocities, pressure, time averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT). Low TAWSS and high OSI and RRT are generally associated with flow stasis and thrombosis. Results LA flow dynamics differed significantly between the two groups. On average, after LAAO, the Amulet patients exhibited a 25% increase in TAWSS and 24% decrease in RRT while the Watchman FLX patients exhibited, on average, a 24% decrease in TAWSS and a 23% increase in RRT. Both populations experienced an increase in LA pressure (~10% for Amulet patients and 16% for Watchman FLX patients). Increased DRT volume seems to be correlated with low TAWSS and elevated RRT. Conclusion This preliminary study suggests that the Amulet device might be associated with improved LA flow dynamics and a potentially lower incidence of DRT compared with the Watchman. However, a larger clinical study is needed to confirm these findings.
Left Atrial Appendage Occlusion vs Standard of Care After Ischemic Stroke Despite Anticoagulation
ImportancePatients with atrial fibrillation (AF) who have ischemic stroke despite taking oral anticoagulation therapy (OAT) have a very high risk of recurrence. Left atrial appendage occlusion (LAAO) is a mechanical stroke prevention strategy that may provide additional protection in patients with thromboembolic events under OAT.ObjectiveTo compare percutaneous LAAO with continuing OAT alone regarding stroke prevention in patients with AF who had a thromboembolic event despite taking OAT.Design, Setting, and ParticipantsThis cohort study was a propensity score–matched comparison of the STR-OAC LAAO cohort, an international collaboration of 21 sites combining patients from multiple prospective registries of patients who underwent LAAO between 2010 and 2022. STR-OAC LAAO cohort patients who had follow-up longer than 3 months were propensity score–matched to a previously published control cohort comprising patients from an established international collaboration of investigator-initiated prospective studies. This control cohort included patients with nonvalvular AF, recent ischemic stroke or transient ischemic attack, and follow-up longer than 3 months who were taking OAT before the index event. Analyses were adjusted for imbalances in gender, age, hypertension, diabetes, and CHA2 DS2-VASc score.ExposureLeft atrial appendage occlusion vs continuation of oral anticoagulation therapy alone (control group).Main Outcomes and MeasuresThe primary outcome was time to first ischemic stroke.ResultsFour hundred thirty-three patients from the STR-OAC LAAO cohort (mean [SD] age, 72 [9] years; 171 [39%] females and 262 [61%] males; mean [SD] CHA2 DS2-VASc score, 5.0 [1.6]) were matched to 433 of 1140 patients (38%) from the control group. During 2-year follow-up, 50 patients experienced ischemic stroke: an annualized event rate of 2.8% per patient-year in the STR-OAC LAAO group vs 8.9% per patient-year in the control group. Left atrial appendage occlusion was associated with a lower risk of ischemic stroke (hazard ratio, 0.33; 95% CI, 0.19-0.58; P < .001) compared with the control group. After LAAO, OAT was discontinued in 290 patients (67%), and the remaining 143 patients (33%) continued OAT after LAAO as an adjunctive therapy.Conclusions and RelevanceIn patients with nonvalvular AF and a prior thromboembolic event despite taking OAT, LAAO was associated with a lower risk of ischemic stroke compared with continued OAT alone. Randomized clinical trial data are needed to confirm that LAAO may be a promising treatment option for this population with a very high risk of stroke.
Reproducibility of cardiac computed tomography classifications of hypoattenuated thickening and peridevice leak following left atrial appendage closure
Abstract Aims To assess the reproducibility of interpreting hypoattenuated thickening (HAT) and peridevice leak (PDL) using cardiac computed tomography (CT) imaging following Watchman FLX left atrial appendage closure (LAAC). Methods and results In this multicentre retrospective reproducibility study, 100 anonymized post-LAAC cardiac CT scans were evaluated within the same cardiac phase by an experienced and a novice rater blinded to prior evaluations. All scans were evaluated twice by each rater, assessing overall HAT and PDL categories as well as specific associated findings based on suggested algorithms for post-LAAC interpretation. Inter- and intra-rater agreement and reliability were evaluated using absolute agreement, Cohen’s kappa, and Kendall’s tau for categorical variables, and mean difference, Bland–Altman plots, limits of agreement (lower and upper), and intra-class correlation coefficients (ICCs) for continuous variables. Within overall categories of both HAT and PDL, substantial agreement (kappa ≥0.61) and reliability (Kendall’s tau-b ≥ 0.75) were observed. Specifically, identifying high-grade HAT (kappa ≥0.78) and distal patency (kappa ≥0.85) displayed the highest agreement within HAT and PDL interpretation. Meanwhile, measuring the height of the proximal screw hub cove represented the least reliable HAT assessment among both inter- and intra-rater comparisons (ICC < 0.75), while suspected leak mechanism represented the least reproducible PDL measure. Conclusion Despite only minimal training of one rater, overall high levels of inter- and intra-rater agreement and reliability were observed across the chosen algorithms for interpretation of HAT and PDL following Watchman FLX LAAC. The prognostic implications of the included variables are to be explored in future trials and registries.
Understanding the role of the left atrial appendage on the flow in the atrium
Abstract Background The exclusion/occlusion of the left atrial appendage (LAA) is a treatment option for atrial fibrillation (AF) patients who are at high risk of stroke and high risk of bleeding. As the role of the LAA is not well understood or explored, this study aims to assess its role on flow dynamics in the left atrium. Methods Computational fluid dynamics (CFD) simulations were carried out for nine AF patients before and after LAA exclusion. The flow parameters investigated included the LA velocities, Time Averaged Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI), Relative Residence Time (RRT), and Pressure in the LA. Results This study shows that, on average, a decrease in TAWSS (1.82 ± 1.85 Pa to 1.27 ± 0.96 Pa, p < 0.05) and a slight increase in OSI (0.16 ± 0.10 to 0.17 ± 0.10, p < 0.05), RRT (1.87 ± 1.84 Pa −1 to 2.11 ± 1.78 Pa −1 , p < 0.05), and pressure (−19.2 ± 6.8 mmHg to −15.3 ± 8.3 mmHg, p < 0.05) were observed in the LA after the exclusion of the LAA, with a decrease in low‐magnitude velocities. Conclusion The exclusion of the LAA seems to be associated with changes in LA flow dynamics. Further studies are needed to elucidate the clinical implications of these changes.
Cardiac computed tomography following Watchman FLX implantation: device-related thrombus or device healing?
Abstract Aims Cardiac computed tomography (CT) is increasingly utilized during follow-up after left atrial appendage closure (LAAC). Hypoattenuated thickening (HAT) is a common finding and might represent either benign device healing or device-related thrombosis (DRT). The appearance and characteristics of HAT associated with the Watchman FLX have not been previously described. Therefore, we sought to investigate cardiac CT findings during follow-up after Watchman FLX implantation with a focus on HAT and DRT. Methods and results Retrospective single-centre, observational study including all patients with successful Watchman FLX implantation and follow-up cardiac CT between March 2019 and September 2021 (n = 244). Blinded analysis of CT images was performed describing the localization, extent, and morphology of HAT and correlated to imaging and histology findings in a canine model. Relevant clinical and preclinical ethical approvals were obtained. Overall, HAT was present in 156 cases (64%) and could be classified as either subfabric hypoattenuation (n = 59), flat sessile HAT (n = 78), protruding sessile HAT (n = 16), or pedunculated HAT (n = 3). All cases of pedunculated HAT and five cases of protruding sessile HAT were considered as high-grade HAT (n = 7). Subfabric hypoattenuation and flat sessile HAT correlated with device healing and endothelialization in histological analysis of explanted devices. Conclusion Subfabric hypoattenuation and flat sessile HAT are frequent CT findings for Watchman FLX, likely representing benign device healing and endothelialization. Pedunculated HAT and protruding HAT are infrequent CT findings that might represent DRT.
Intracardiac echocardiography for guidance of transcatheter left atrial appendage occlusion: An expert consensus document