Back to Authors

Jensen, Jesper Møller

https://orcid.org/0000-0002-4179-4471

Mayo Clinic

Aarhus University Hospital

Citations 2

Reproducibility of cardiac computed tomography classifications of hypoattenuated thickening and peridevice leak following left atrial appendage closure
Kramer, Anders , Russo, Gerardo Lo , Alarouri, Hasan S. , Collins, Jeremy D. , Jensen, Jesper Møller , Nielsen‐Kudsk, Jens Erik , Alkhouli, Mohamad , Korsholm, Kasper , Lo Russo, Gerardo , Møller Jensen, Jesper , Alkhouli, Mohamad , Collins, Jeremy , Korsholm, Kasper , Kramer, Anders Dahl

European Heart Journal - Cardiovascular Imaging | September 2, 2024 | Volume: 26 | Issue: 1 | Pages: 62-71

10.1093/ehjci/jeae236 Get It

Abstract Aims To assess the reproducibility of interpreting hypoattenuated thickening (HAT) and peridevice leak (PDL) using cardiac computed tomography (CT) imaging following Watchman FLX left atrial appendage closure (LAAC). Methods and results In this multicentre retrospective reproducibility study, 100 anonymized post-LAAC cardiac CT scans were evaluated within the same cardiac phase by an experienced and a novice rater blinded to prior evaluations. All scans were evaluated twice by each rater, assessing overall HAT and PDL categories as well as specific associated findings based on suggested algorithms for post-LAAC interpretation. Inter- and intra-rater agreement and reliability were evaluated using absolute agreement, Cohen’s kappa, and Kendall’s tau for categorical variables, and mean difference, Bland–Altman plots, limits of agreement (lower and upper), and intra-class correlation coefficients (ICCs) for continuous variables. Within overall categories of both HAT and PDL, substantial agreement (kappa ≥0.61) and reliability (Kendall’s tau-b ≥ 0.75) were observed. Specifically, identifying high-grade HAT (kappa ≥0.78) and distal patency (kappa ≥0.85) displayed the highest agreement within HAT and PDL interpretation. Meanwhile, measuring the height of the proximal screw hub cove represented the least reliable HAT assessment among both inter- and intra-rater comparisons (ICC < 0.75), while suspected leak mechanism represented the least reproducible PDL measure. Conclusion Despite only minimal training of one rater, overall high levels of inter- and intra-rater agreement and reliability were observed across the chosen algorithms for interpretation of HAT and PDL following Watchman FLX LAAC. The prognostic implications of the included variables are to be explored in future trials and registries.
Cardiac computed tomography following Watchman FLX implantation: device-related thrombus or device healing?
Kramer, Anders , Korsholm, Kasper , Jensen, Jesper Møller , Nørgaard, Bjarne Linde , Peelukhana, Srikara, Herbst, Thomáš, Horton, Rodney , Kar, Saibal , Saw, Jacqueline , Alkhouli, Mohamad , Nielsen‐Kudsk, Jens Erik , Kramer, Anders Dahl , Alkhouli, Mohamad , Korsholm, Kasper , Møller Jensen, Jesper , Nørgaard, Bjarne Linde , Peelukhana, Srikara Viswanath

European Heart Journal - Cardiovascular Imaging | October 20, 2022 | Volume: 24 | Issue: 2 | Pages: 250-259

10.1093/ehjci/jeac222 Get It

Abstract Aims Cardiac computed tomography (CT) is increasingly utilized during follow-up after left atrial appendage closure (LAAC). Hypoattenuated thickening (HAT) is a common finding and might represent either benign device healing or device-related thrombosis (DRT). The appearance and characteristics of HAT associated with the Watchman FLX have not been previously described. Therefore, we sought to investigate cardiac CT findings during follow-up after Watchman FLX implantation with a focus on HAT and DRT. Methods and results Retrospective single-centre, observational study including all patients with successful Watchman FLX implantation and follow-up cardiac CT between March 2019 and September 2021 (n = 244). Blinded analysis of CT images was performed describing the localization, extent, and morphology of HAT and correlated to imaging and histology findings in a canine model. Relevant clinical and preclinical ethical approvals were obtained. Overall, HAT was present in 156 cases (64%) and could be classified as either subfabric hypoattenuation (n = 59), flat sessile HAT (n = 78), protruding sessile HAT (n = 16), or pedunculated HAT (n = 3). All cases of pedunculated HAT and five cases of protruding sessile HAT were considered as high-grade HAT (n = 7). Subfabric hypoattenuation and flat sessile HAT correlated with device healing and endothelialization in histological analysis of explanted devices. Conclusion Subfabric hypoattenuation and flat sessile HAT are frequent CT findings for Watchman FLX, likely representing benign device healing and endothelialization. Pedunculated HAT and protruding HAT are infrequent CT findings that might represent DRT.