Back to Authors

Sularz, Agata

https://orcid.org/0000-0002-4019-6410

Mayo Clinic

Mayo Clinic

Citations 5

Non-bacterial thrombotic endocarditis and intraventricular small-vessel thromboembolic occlusion mimicking immune checkpoint inhibitor myocarditis in a patient treated with pembrolizumab: a case report
Sularz, Agata , Holthe, Jordan , Geske, Jeffrey B, Bois, Melanie C. , Bois, John, Holthe, Jordan A, Bois, John P , Sularz, Agata , Geske, Jeffrey B. , Bois, John P.

European Heart Journal - Case Reports | May 9, 2026 | Volume: 10 | Issue: 5 | Pages: No page available

10.1093/ehjcr/ytag305 Get It

Abstract Background Immune checkpoint inhibitors (ICIs) have revolutionized cancer treatment and are increasingly associated with cardiovascular toxicities, including myocarditis and accelerated atherosclerosis. While ICI myocarditis has received substantial attention, thrombotic complications remain underrecognized and may be difficult to distinguish from immune-mediated cardiac inflammation and cancer-related hypercoagulable state. We present a case of non-bacterial thrombotic endocarditis (NBTE) and myocardial microthrombi mimicking ICI myocarditis. Case summary A 76-year-old woman with metastatic adenosquamous lung carcinoma presented with progressive dyspnoea 3 weeks after initiating pembrolizumab. Pulmonary arterial and coronary imaging were unremarkable, but cardiac magnetic resonance imaging (MRI) showed late gadolinium enhancement (LGE) and myocardial oedema suggestive of ICI myocarditis. Chest computed tomography revealed inflammatory lung changes, and empirical corticosteroids were initiated with initial clinical improvement. One week later, brain MRI showed multifocal infarcts, and Doppler ultrasound identified bilateral lower extremity deep vein thromboses. Transoesophageal echocardiography showed thickened mitral and aortic valves with moderate regurgitation. Non-bacterial thrombotic endocarditis with embolic phenomena was suspected. Anticoagulation was escalated from apixaban to therapeutic enoxaparin, followed by warfarin. Despite initial stabilization, the patient died 2 months later. Post-mortem examination revealed fibrin-rich valvular vegetations consistent with NBTE, widespread intramyocardial thrombi, and no histopathologic evidence of myocarditis. Discussion This case underscores how microthrombotic complications of ICI therapy may closely mimic myocarditis on imaging. Nonspecific cardiac MRI findings, such as LGE and T2 signal elevation, can result from thrombotic or ischaemic injury alike. Histopathologic confirmation may be required for accurate diagnosis, as misclassification can lead to suboptimal treatment.
Comparison of Flow Dynamics After Left Atrial Appendage Occlusion With the Watchman FLX Versus Amulet Devices: Implications for Device‐Related Thrombosis
Bshennaty, Ahmad , Vogl, Brennan , Bavo, Alessandra , Ghazal‐Aswad, Karam, Kramer, Anders , Jia, Yuheng , Beule, Matthieu De , Nielsen‐Kudsk, Jens Erik , Saleh, Ghasaq, Bavo, Alessandra Maria , Sularz, Agata , Ghazal-Aswad, Karam, Jia, Yuheng , De Backer, Ole , Hatoum, Hoda , Kramer, Anders Dahl , Saleh, Ghasaq , Sularz, Agata , Backer, Ole De , Alkhouli, Mohamad , Hatoum, Hoda

Catheterization and Cardiovascular Interventions | June 25, 2025 | Volume: 106 | Issue: 4 | Pages: 2084-2092

10.1002/ccd.31710 Get It

ABSTRACT Background This study aims to assess how Watchman FLX (Boston Scientific) and Amplatzer Amulet (Abbott) devices for left atrial appendage occlusion (LAAO) impact the flow dynamics in the LA and the risk of device‐related thrombosis (DRT). Methods Flow simulations were carried out for 12 AF patients before and after undergoing LAAO. Six patients had Watchman FLX while the other six had Amulet devices, of which three in each group had DRT. The flow parameters investigated included the LA velocities, pressure, time averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT). Low TAWSS and high OSI and RRT are generally associated with flow stasis and thrombosis. Results LA flow dynamics differed significantly between the two groups. On average, after LAAO, the Amulet patients exhibited a 25% increase in TAWSS and 24% decrease in RRT while the Watchman FLX patients exhibited, on average, a 24% decrease in TAWSS and a 23% increase in RRT. Both populations experienced an increase in LA pressure (~10% for Amulet patients and 16% for Watchman FLX patients). Increased DRT volume seems to be correlated with low TAWSS and elevated RRT. Conclusion This preliminary study suggests that the Amulet device might be associated with improved LA flow dynamics and a potentially lower incidence of DRT compared with the Watchman. However, a larger clinical study is needed to confirm these findings.
Immediate Reduction in Left Ventricular Contractility After Mitral Transcatheter Edge‐to‐Edge Repair Is Associated With Lower Rates of Heart Failure Hospitalizations
Chen, Ke‐Wei , Chang, Jeng-Sheng , Sularz, Agata , Russo, Gerardo Lo , Chang, Shih‐Sheng , Liu, C H, Alkhouli, Mohamad , Chang, Ju-Hsin , Lo Russo, Gerardo , Saleh, Ghasaq, Chang, Shih-Sheng , Liu, Chia-Hao , Alkhouli, Mohamad , Sularz, Agata , Saleh, Ghasaq

Journal of the American Heart Association | February 26, 2025 | Volume: 14 | Issue: 5 | Pages: No page available

10.1161/jaha.124.037545 Get It

Understanding the role of the left atrial appendage on the flow in the atrium
Bshennaty, Ahmad , Vogl, Brennan , Bavo, Alessandra , Kramer, Anders , Jia, Yuheng, Beule, Matthieu De , Nielsen‐Kudsk, Jens Erik , Backer, Ole De , Alkhouli, Mohamad , Bavo, Alessandra Maria , Sularz, Agata , Kramer, Anders Dahl , De Backer, Ole , Hatoum, Hoda , Sularz, Agata , Alkhouli, Mohamad , Hatoum, Hoda

Catheterization and Cardiovascular Interventions | July 21, 2024 | Volume: 104 | Issue: 6 | Pages: 1290-1298

10.1002/ccd.31153 Get It

Abstract Background The exclusion/occlusion of the left atrial appendage (LAA) is a treatment option for atrial fibrillation (AF) patients who are at high risk of stroke and high risk of bleeding. As the role of the LAA is not well understood or explored, this study aims to assess its role on flow dynamics in the left atrium. Methods Computational fluid dynamics (CFD) simulations were carried out for nine AF patients before and after LAA exclusion. The flow parameters investigated included the LA velocities, Time Averaged Wall Shear Stress (TAWSS), Oscillatory Shear Index (OSI), Relative Residence Time (RRT), and Pressure in the LA. Results This study shows that, on average, a decrease in TAWSS (1.82 ± 1.85 Pa to 1.27 ± 0.96 Pa, p < 0.05) and a slight increase in OSI (0.16 ± 0.10 to 0.17 ± 0.10, p < 0.05), RRT (1.87 ± 1.84 Pa −1 to 2.11 ± 1.78 Pa −1 , p < 0.05), and pressure (−19.2 ± 6.8 mmHg to −15.3 ± 8.3 mmHg, p < 0.05) were observed in the LA after the exclusion of the LAA, with a decrease in low‐magnitude velocities. Conclusion The exclusion of the LAA seems to be associated with changes in LA flow dynamics. Further studies are needed to elucidate the clinical implications of these changes.
Association of Bovine Arch Anatomy With Incident Stroke After Transcatheter Aortic Valve Replacement
Russo, Gerardo Lo , Alarouri, Hasan S. , Al‐Abcha, Abdullah , Vogl, Brennan , Mahayni, Abdulah , Sularz, Agata , Hatoum, Hoda , Collins, Jeremy D. , Crestanello, Juan A. , Alkhouli, Mohamad , Lo Russo, Gerardo V, Al-Abcha, Abdulah , Collins, Jeremy , Alkhouli, Mohamad , Crestanello, Juan A , Hatoum, Hoda , Lo Russo, Gerardo , Sularz, Agata

Journal of the American Heart Association | February 13, 2024 | Volume: 13 | Issue: 4 | Pages: No page available

10.1161/jaha.123.032963 Get It

Background Acute ischemic stroke complicates 2% to 3% of transcatheter aortic valve replacements (TAVRs). This study aimed to identify the aortic anatomic correlates in patients after TAVR stroke. Methods and Results This is a single‐center, retrospective study of patients who underwent TAVR at the Mayo Clinic between 2012 and 2022. The aortic arch morphology was determined via a manual review of the pre‐TAVR computed tomography images. An “a priori” approach was used to select the covariates for the following: (1) the logistic regression model assessing the association between a bovine arch and periprocedural stroke (defined as stroke within 7 days after TAVR); and (2) the Cox proportional hazards regression model assessing the association between a bovine arch and long‐term stroke after TAVR. A total of 2775 patients were included (59.6% men; 97.8% White race; mean±SD age, 79.3±8.4 years), of whom 495 (17.8%) had a bovine arch morphology. Fifty‐seven patients (1.7%) experienced a periprocedural stroke. The incidence of acute stroke was significantly higher among patients with a bovine arch compared with those with a nonbovine arch (3.6% versus 1.7%; P =0.01). After adjustment, a bovine arch was independently associated with increased periprocedural strokes (adjusted odds ratio, 2.16 [95% CI, 1.22–3.83]). At a median follow‐up of 2.7 years, the overall incidence of post‐TAVR stroke was 6.0% and was significantly higher in patients with a bovine arch even after adjusting for potential confounders (10.5% versus 5.0%; adjusted hazard ratio, 2.11 [95% CI, 1.51–2.93]; P <0.001). Conclusions A bovine arch anatomy is associated with a significantly higher risk of periprocedural and long‐term stroke after TAVR.