BACKGROUND: Whether vigorous exercise increases risk of ventricular arrhythmias for individuals diagnosed and treated for congenital long QT syndrome (LQTS) remains unknown. METHODS: The National Institutes of Health–funded LIVE-LQTS study (Lifestyle and Exercise in the Long QT Syndrome) prospectively enrolled individuals 8 to 60 years of age with phenotypic and/or genotypic LQTS from 37 sites in 5 countries from May 2015 to February 2019. Participants (or parents) answered physical activity and clinical events surveys every 6 months for 3 years with follow-up completed in February 2022. Vigorous exercise was defined as ≥6 metabolic equivalents for >60 hours per year. A blinded Clinical Events Committee adjudicated the composite end point of sudden death, sudden cardiac arrest, ventricular arrhythmia treated by an implantable cardioverter defibrillator, and likely arrhythmic syncope. A National Death Index search ascertained vital status for those with incomplete follow-up. A noninferiority hypothesis (boundary of 1.5) between vigorous exercisers and others was tested with multivariable Cox regression analysis. RESULTS: Among the 1413 participants (13% <18 years of age, 35% 18–25 years of age, 67% female, 25% with implantable cardioverter defibrillators, 90% genotype positive, 49% with LQT1, 91% were treated with beta-blockers, left cardiac sympathetic denervation, and/or implantable cardioverter defibrillator), 52% participated in vigorous exercise (55% of these competitively). Thirty-seven individuals experienced the composite end point (including one sudden cardiac arrest and one sudden death in the nonvigorous group, one sudden cardiac arrest in the vigorous group) with overall event rates at 3 years of 2.6% in the vigorous and 2.7% in the nonvigorous exercise groups. The unadjusted hazard ratio for experience of events for the vigorous group compared with the nonvigorous group was 0.97 (90% CI, 0.57–1.67), with an adjusted hazard ratio of 1.17 (90% CI, 0.67–2.04). The upper 95% one-sided confidence level extended beyond the 1.5 boundary. Neither vigorous or nonvigorous exercise was found to be superior in any group or subgroup. CONCLUSIONS: Among individuals diagnosed with phenotypic and/or genotypic LQTS who were risk assessed and treated in experienced centers, LQTS-associated cardiac event rates were low and similar between those exercising vigorously and those not exercising vigorously. Consistent with the low event rate, CIs are wide, and noninferiority was not demonstrated. These data further inform shared decision-making discussions between patient and physician about exercise and competitive sports participation. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02549664.
Molecular characterization of the calcium release channel deficiency syndrome
We identified a potentially novel homozygous duplication involving the promoter region and exons 1–4 of the gene encoding type 2 cardiac ryanodine receptor ( RYR2 ) that is responsible for highly penetrant, exertion-related sudden deaths/cardiac arrests in the Amish community without an overt phenotype to suggest RYR2- mediated catecholaminergic polymorphic ventricular tachycardia (CPVT). Homozygous RYR2 duplication (RYR2-DUP) induced pluripotent stem cell cardiomyocytes (iPSC-CMs) were generated from 2 unrelated patients. There was no difference in baseline Ca 2+ handling measurements between WT-iPSC-CM and RYR2-DUP-iPSC-CM lines. However, compared with WT-iPSC-CMs, both patient lines demonstrated a dramatic reduction in caffeine-stimulated and isoproterenol-stimulated (ISO-stimulated) Ca 2+ transient amplitude, suggesting RyR2 loss of function. There was a greater than 50% reduction in RYR2 transcript/RyR2 protein expression in both patient iPSC-CMs compared with WT. Delayed afterdepolarization was observed in the RYR2-DUP-iPSC-CMs but not in the WT-iPSC-CMs. Compared with WT-iPSC-CMs, there was significantly elevated arrhythmic activity in the RYR2-DUP-iPSC-CMs in response to ISO. Nadolol, propranolol, and flecainide reduced erratic activity by 8.5-fold, 6.8-fold, and 2.4-fold, respectively, from ISO challenge. Unlike the gain-of-function mechanism observed in RYR2- mediated CPVT, the homozygous multiexon duplication precipitated a dramatic reduction in RYR2 transcription and RyR2 protein translation, a loss of function in calcium handling, and a calcium-induced calcium release apparatus that is insensitive to catecholamines and caffeine.
Identification of a Novel Homozygous Multi-Exon Duplication in RYR2 Among Children With Exertion-Related Unexplained Sudden Deaths in the Amish Community
Background: Despite safety concerns, many young patients with implantable cardioverter-defibrillators (ICDs) participate in sports. We undertook a prospective, multinational registry to determine the incidence of serious adverse events because of sports participation. The primary end points were death or resuscitated arrest during sports or injury during sports because of arrhythmia or shock. Secondary end points included system malfunction and incidence of ventricular arrhythmias requiring multiple shocks for termination. Methods: Athletes with ICDs aged ≤21 years were included in this post hoc subanalysis of the ICD Sports Registry. Data on sports and clinical outcomes were obtained by phone interview and medical records review. ICD shocks and clinical details of lead malfunction were classified by 2 electrophysiologists. Results: A total of 129 young athletes participating in competitive (n=117) or dangerous (n=12) sports were enrolled. The mean age was 16 years (range, 10–21; 40% female; 92% white). The most common diagnoses were long QT syndrome (n=49), hypertrophic cardiomyopathy (n=30), and congenital heart disease (n=16). The most common sports were basketball and soccer, including 79 varsity/junior varsity high school and college athletes. During a median follow-up of 42 months, 35 athletes (27%) received 38 shocks. There were no occurrences of death, arrest, or injury related to arrhythmia, during sports. There was 1 ventricular tachycardia/ventricular fibrillation storm during competition. Freedom from lead malfunction was 92.3% at 5 years and 79.6% at 10 years. Conclusions: Although shocks related to competition/practice are not uncommon, there were no serious adverse sequelae. Lead malfunction rates were similar to previously reported in unselected pediatric ICD populations. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00637754.
Cosmetic outcomes and quality of life in children with cardiac implantable electronic devices
AbstractBackgroundAxillary implant location is an alternative implant location in patients for cardiac implantable electronic devices (CIEDs) for the purposes of improved cosmetic outcome. The impact from the patient's perspective is unknown. The purpose of this study was to compare scar perception scores and quality of life (QOL) in pediatric patients with axillary CIED implant location versus the standard infraclavicular approach.MethodsThis is a multicenter prospective study conducted at eight pediatric centers and it includes patients aged from 8 to 18 years with a CIED. Patients with prior sternotomy were excluded. Scar perception and QOL outcomes were compared between the infraclavicular and axillary implant locations.ResultsA total of 141 patients (83 implantable cardioverter defibrillator [ICD]/58 pacemakers) were included, 55 with an axillary device and 86 with an infraclavicular device. Patients with an ICD in the axillary position had better perception of scar appearance and consciousness. Patients in the axillary group reported, on average, a total Pediatric QOL Inventory score that was 6 (1, 11) units higher than the infraclavicular group, after adjusting for sex and race (P = 0.02).ConclusionsQOL is significantly improved in axillary in comparison to the infraclavicular CIED position, regardless of device type. Scar perception is improved in patients with ICD in the axillary position.
Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators
Background— Implantable cardioverter-defibrillator (ICD) therapy in children and congenital heart disease patients is hampered by poor long-term lead survival. Lead extraction is technically difficult and carries substantial morbidity. We sought to determine the outcomes of ICD leads in pediatric and congenital heart disease patients. Methods and Results— The Pediatric Lead Extractability and Survival Evaluation (PLEASE) is a 24-center international registry. Pediatric and congenital heart disease patients with ICD lead implantations from 2005 to 2010 were eligible. Study subjects comprised 878 ICD patients (44% congenital heart disease). Mean±SD age at implantation was 18.6±9.8 years. Of the 965 total leads, 54% were thin (≤7F), of which 57% were Fidelis, and 23% were coated with expanded polytetrafluoroethylene. There were 139 ICD lead failures (14%) in 132 patients (15%) at a mean lead age of 2.0±1.4 years, causing shocks in 53 patients (40%). Independent predictors of lead failure included younger implantation age and Fidelis leads. Actuarial analysis showed an incremental risk of lead failure with younger age at implantation: <8 years compared with >18 years ( P =0.015). The actuarial yearly failure rate was 2.3% for non-Fidelis and 9.1% for Fidelis leads. Extraction was performed on 143 leads (80% thin, 7% expanded polytetrafluoroethylene coated), with lead age as the only independent predictor for advanced extraction techniques. There were 6 major extraction complications (4%) but no procedural mortality. Conclusions— This study demonstrates that ICD leads in children and congenital heart disease patients have an age-related suboptimal performance, further compounded by a high failure rate of Fidelis leads. Advanced extraction techniques were common and correlated with older lead age. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00335036.
Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators
Background— The risks of sports participation for implantable cardioverter-defibrillator (ICD) patients are unknown. Methods and Results— Athletes with ICDs (age, 10–60 years) participating in organized (n=328) or high-risk (n=44) sports were recruited. Sports-related and clinical data were obtained by phone interview and medical records. Follow-up occurred every 6 months. ICD shock data and clinical outcomes were adjudicated by 2 electrophysiologists. Median age was 33 years (89 subjects <20 years of age); 33% were female. Sixty were competitive athletes (varsity/junior varsity/traveling team). A pre-ICD history of ventricular arrhythmia was present in 42%. Running, basketball, and soccer were the most common sports. Over a median 31-month (interquartile range, 21–46 months) follow-up, there were no occurrences of either primary end point—death or resuscitated arrest or arrhythmia- or shock-related injury—during sports. There were 49 shocks in 37 participants (10% of study population) during competition/practice, 39 shocks in 29 participants (8%) during other physical activity, and 33 shocks in 24 participants (6%) at rest. In 8 ventricular arrhythmia episodes (device defined), multiple shocks were received: 1 at rest, 4 during competition/practice, and 3 during other physical activity. Ultimately, the ICD terminated all episodes. Freedom from lead malfunction was 97% at 5 years (from implantation) and 90% at 10 years. Conclusions— Many athletes with ICDs can engage in vigorous and competitive sports without physical injury or failure to terminate the arrhythmia despite the occurrence of both inappropriate and appropriate shocks. These data provide a basis for more informed physician and patient decision making in terms of sports participation for athletes with ICDs.