ABSTRACT Objectives Multicenter research of geriatric emergency department (GED) care remains limited. Our objectives were to: 1. Prospectively collect data prioritized by the Geriatric Emergency care Applied Research (GEAR) network, a transdisciplinary taskforce for GED care, and create a multicenter GED research repository of prospective and electronic health record (EHR) data, 2. Assess concordance between prospective and EHR data. Methods The GEAR Standardization Study (GEARSS) is a multicenter, prospective study of older emergency department (ED) patients (65+) focusing on the 4Ms of age‐friendly care (mobility, medication safety, mentation, what matters) and elder mistreatment. Demographic and clinical data were collected via interviews by trained research assistants (RA) on Days 0, 4, 30, and 90 and linked to EHR. Prevalence of chronic comorbidities and incident delirium were measured and reported using descriptive statistics. Prospective and EHR data concordance was assessed with Cohen's Kappa. Results 999 participants were recruited from 5 EDs (3/25/2021–6/30/2022) across 3 institutions: Grady Health System, Northwestern Memorial Hospital, and Yale New Haven Health. The cohort was 57.0% female, 55.2% White, 39.1% Black, and 3.4% Hispanic, and the mean age was 75.1 years. For rheumatologic disease, peptic ulcer disease, diabetes, renal disease, and cancer, prevalence differed between prospective and EHR data by > 10%. About two‐thirds of participants were at risk for falls. Concordance between prospective and EHR data was good for ethnicity ( K = 0.73); excellent for sex ( K = 1.00), age ( K = 1.00), and race ( K = 0.98); fair for disposition ( K = 0.53); slight for ED observation status ( K = 0.33) and dementia diagnosis ( K = 0.24); poor for delirium presence ( K = 0.07). Conclusion In GEARSS, demographic variables aligned strongly between prospective and EHR data, while diagnosis, disposition, and mentation factors did not. This multicenter data source provides preliminary findings for common geriatric syndromes and conditions. Choice of measures using these data should be driven by GED research questions.
The
PRO
‐
AGE
Tool and Its Association With Post Discharge Outcomes in Older Adults Admitted From the Emergency Department
ABSTRACT Background Existing risk scores assessing geriatric vulnerability in the emergency department (ED) have shown limited predictive power, especially in diverse populations. We investigated the relationship of a quick and easy‐to‐administer geriatric vulnerability scoring system with functional decline and mortality in older patients admitted to multiple hospitals through the ED in the United States (US) and Brazil (BR). Method Federated, international, multicenter observational study of hospitalized ED patients aged ≥ 65 from US and BR. The six criteria from the PRO‐AGE score (Physical impairment, Recent hospitalization, Older age [≥ 90], Acute mental alteration, Getting thinner, and Exhaustion; 0–8; higher scores = greater vulnerability) were assessed on admission. We used proportional hazards models to investigate the relationships between PRO‐AGE score groups and 90‐day mortality and functional decline, defined as new dependence in activities of daily living (ADL) and instrumental ADL (IADL), after adjusting for age, sex, race and ethnicity, education, Charlson comorbidity score, and study site. Death was considered a competing event for the functional decline outcome. Results A total of 1390 patients were included (US = 560; Brazil = 830). The 90‐day risk of death was higher for the upper compared with the lower (reference) PRO‐AGE group in both cohorts (US: HR = 11.76; 95% confidence interval [CI] = 2.56–54.04; BR: HR = 12.29; 95% CI = 3.54–42.59), whereas the risk of new 90‐day ADL disability was higher for upper (HR = 2.08; 95% CI = 1.21–3.56) and middle groups (HR = 2.10; 95% CI = 1.35–3.27) in the US but only the upper group in BR (HR = 1.70; 95% CI = 1.02–2.85). Conclusion A higher PRO‐AGE score was associated with mortality and functional decline in older ED patients admitted to hospitals in the US and BR, demonstrating its generalizability as a geriatric vulnerability risk score.
Safety of Sports for Young Patients With Implantable Cardioverter-Defibrillators
Background: Despite safety concerns, many young patients with implantable cardioverter-defibrillators (ICDs) participate in sports. We undertook a prospective, multinational registry to determine the incidence of serious adverse events because of sports participation. The primary end points were death or resuscitated arrest during sports or injury during sports because of arrhythmia or shock. Secondary end points included system malfunction and incidence of ventricular arrhythmias requiring multiple shocks for termination. Methods: Athletes with ICDs aged ≤21 years were included in this post hoc subanalysis of the ICD Sports Registry. Data on sports and clinical outcomes were obtained by phone interview and medical records review. ICD shocks and clinical details of lead malfunction were classified by 2 electrophysiologists. Results: A total of 129 young athletes participating in competitive (n=117) or dangerous (n=12) sports were enrolled. The mean age was 16 years (range, 10–21; 40% female; 92% white). The most common diagnoses were long QT syndrome (n=49), hypertrophic cardiomyopathy (n=30), and congenital heart disease (n=16). The most common sports were basketball and soccer, including 79 varsity/junior varsity high school and college athletes. During a median follow-up of 42 months, 35 athletes (27%) received 38 shocks. There were no occurrences of death, arrest, or injury related to arrhythmia, during sports. There was 1 ventricular tachycardia/ventricular fibrillation storm during competition. Freedom from lead malfunction was 92.3% at 5 years and 79.6% at 10 years. Conclusions: Although shocks related to competition/practice are not uncommon, there were no serious adverse sequelae. Lead malfunction rates were similar to previously reported in unselected pediatric ICD populations. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00637754.
Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators
Background— The risks of sports participation for implantable cardioverter-defibrillator (ICD) patients are unknown. Methods and Results— Athletes with ICDs (age, 10–60 years) participating in organized (n=328) or high-risk (n=44) sports were recruited. Sports-related and clinical data were obtained by phone interview and medical records. Follow-up occurred every 6 months. ICD shock data and clinical outcomes were adjudicated by 2 electrophysiologists. Median age was 33 years (89 subjects <20 years of age); 33% were female. Sixty were competitive athletes (varsity/junior varsity/traveling team). A pre-ICD history of ventricular arrhythmia was present in 42%. Running, basketball, and soccer were the most common sports. Over a median 31-month (interquartile range, 21–46 months) follow-up, there were no occurrences of either primary end point—death or resuscitated arrest or arrhythmia- or shock-related injury—during sports. There were 49 shocks in 37 participants (10% of study population) during competition/practice, 39 shocks in 29 participants (8%) during other physical activity, and 33 shocks in 24 participants (6%) at rest. In 8 ventricular arrhythmia episodes (device defined), multiple shocks were received: 1 at rest, 4 during competition/practice, and 3 during other physical activity. Ultimately, the ICD terminated all episodes. Freedom from lead malfunction was 97% at 5 years (from implantation) and 90% at 10 years. Conclusions— Many athletes with ICDs can engage in vigorous and competitive sports without physical injury or failure to terminate the arrhythmia despite the occurrence of both inappropriate and appropriate shocks. These data provide a basis for more informed physician and patient decision making in terms of sports participation for athletes with ICDs.