Back to Authors

Scheinman, Melvin M.

https://orcid.org/0000-0002-3793-1867

Mayo Clinic

University of California, San Francisco

Citations 3

A Clinical Diagnostic Test for Calcium Release Deficiency Syndrome
Ni, Mingke , Saenen, Johan , Hoeksema, Wiert F. , Antiperovitch, Pavel , Arnaud, Marine , Tian, Shanshan, Sun, Bo , Estillore, John Paul , Wang, Ruiwu , Khan, Habib , Roston, Thomas M. , Mazzanti, Andrea , Giudicessi, John, Siontis, Konstantinos C. , Alak, Aiman, Acosta, J. Gabriel , Menon, Syamkumar M. Divakara, Tan, Nigel S. , Vivekanantham, Hari , Pandya, Tanvi, Cunningham, Jennifer , Gula, Lorne J. , Wong, Jorge , Amit, Guy , Scheinman, Melvin M. , Ackerman, Michael J. , Priori, Silvia G. , Sacher, Frédéric , Nof, Eyal , Glikson, Michael , Wilde, Arthur A.M. , Jensen, Henrik Kjærulf , Chen, S.R. Wayne , Roberts, Jason D. , Jensen, Henrik Kjærulf , Mazzanti, Andrea , Priori, Silvia , Dadon, Ziv , Ormerod, Julian O.M. , Tadros, Rafik , Christiansen, Morten Krogh , Steinberg, Christian , Giudicessi, John R. , Werf, Christian van der , Nazer, Babak , Krahn, Andrew D. , Gollob, Michael H. , Healey, Jeff S. , Glikson, Michael , Watkins, Hugh , Postema, Pieter G. , Belhassen, Bernard

JAMA | June 20, 2024 | Volume: 332 | Issue: 3 | Pages: 204

10.1001/jama.2024.8599 Get It

Importance Sudden death and cardiac arrest frequently occur without explanation, even after a thorough clinical evaluation. Calcium release deficiency syndrome (CRDS), a life-threatening genetic arrhythmia syndrome, is undetectable with standard testing and leads to unexplained cardiac arrest. Objective To explore the cardiac repolarization response on an electrocardiogram after brief tachycardia and a pause as a clinical diagnostic test for CRDS. Design, Setting, and Participants An international, multicenter, case-control study including individual cases of CRDS, 3 patient control groups (individuals with suspected supraventricular tachycardia; survivors of unexplained cardiac arrest [UCA]; and individuals with genotype-positive catecholaminergic polymorphic ventricular tachycardia [CPVT]), and genetic mouse models (CRDS, wild type, and CPVT were used to define the cellular mechanism) conducted at 10 centers in 7 countries. Patient tracings were recorded between June 2005 and December 2023, and the analyses were performed from April 2023 to December 2023. Intervention Brief tachycardia and a subsequent pause (either spontaneous or mediated through cardiac pacing). Main Outcomes and Measures Change in QT interval and change in T-wave amplitude (defined as the difference between their absolute values on the postpause sinus beat and the last beat prior to tachycardia). Results Among 10 case patients with CRDS, 45 control patients with suspected supraventricular tachycardia, 10 control patients who experienced UCA, and 3 control patients with genotype-positive CPVT, the median change in T-wave amplitude on the postpause sinus beat (after brief ventricular tachycardia at ≥150 beats/min) was higher in patients with CRDS ( P < .001). The smallest change in T-wave amplitude was 0.250 mV for a CRDS case patient compared with the largest change in T-wave amplitude of 0.160 mV for a control patient, indicating 100% discrimination. Although the median change in QT interval was longer in CRDS cases ( P = .002), an overlap between the cases and controls was present. The genetic mouse models recapitulated the findings observed in humans and suggested the repolarization response was secondary to a pathologically large systolic release of calcium from the sarcoplasmic reticulum. Conclusions and Relevance There is a unique repolarization response on an electrocardiogram after provocation with brief tachycardia and a subsequent pause in CRDS cases and mouse models, which is absent from the controls. If these findings are confirmed in larger studies, this easy to perform maneuver may serve as an effective clinical diagnostic test for CRDS and become an important part of the evaluation of cardiac arrest.
Safety of Sports for Athletes With Implantable Cardioverter-Defibrillators
Lampert, Rachel , Olshansky, Brian , Heidbüchel, Hein , Lawless, Christine E., Saarel, Elizabeth V. , Ackerman, Michael J. , Calkins, Hugh , Maron, Barry J. , Scheinman, Melvin M. , Wilkoff, Bruce L. , Zipes, Douglas P. , Berul, Charles I. , Cheng, Alan , Law, Ian H. , Loomis, Michele, Barth, Cheryl , Dziura, James , Cannom, David S. , Estes, N.A. Mark , Link, Mark S. , Marcus, Gregory M. , Brandt, Cynthia , Li, Fangyong , Olshansky, Brian , Law, Ian H , Zipes, Douglas P

Circulation | May 20, 2013 | Volume: 127 | Issue: 20 | Pages: 2021-2030

10.1161/circulationaha.112.000447 Get It

Background— The risks of sports participation for implantable cardioverter-defibrillator (ICD) patients are unknown. Methods and Results— Athletes with ICDs (age, 10–60 years) participating in organized (n=328) or high-risk (n=44) sports were recruited. Sports-related and clinical data were obtained by phone interview and medical records. Follow-up occurred every 6 months. ICD shock data and clinical outcomes were adjudicated by 2 electrophysiologists. Median age was 33 years (89 subjects <20 years of age); 33% were female. Sixty were competitive athletes (varsity/junior varsity/traveling team). A pre-ICD history of ventricular arrhythmia was present in 42%. Running, basketball, and soccer were the most common sports. Over a median 31-month (interquartile range, 21–46 months) follow-up, there were no occurrences of either primary end point—death or resuscitated arrest or arrhythmia- or shock-related injury—during sports. There were 49 shocks in 37 participants (10% of study population) during competition/practice, 39 shocks in 29 participants (8%) during other physical activity, and 33 shocks in 24 participants (6%) at rest. In 8 ventricular arrhythmia episodes (device defined), multiple shocks were received: 1 at rest, 4 during competition/practice, and 3 during other physical activity. Ultimately, the ICD terminated all episodes. Freedom from lead malfunction was 97% at 5 years (from implantation) and 90% at 10 years. Conclusions— Many athletes with ICDs can engage in vigorous and competitive sports without physical injury or failure to terminate the arrhythmia despite the occurrence of both inappropriate and appropriate shocks. These data provide a basis for more informed physician and patient decision making in terms of sports participation for athletes with ICDs.