A Clinical Diagnostic Test for Calcium Release Deficiency Syndrome
Ni, Mingke , Saenen, Johan , Hoeksema, Wiert F. , Antiperovitch, Pavel , Arnaud, Marine , Tian, Shanshan, Sun, Bo , Estillore, John Paul , Wang, Ruiwu , Khan, Habib , Roston, Thomas M. , Mazzanti, Andrea , Giudicessi, John, Siontis, Konstantinos C. , Alak, Aiman, Acosta, J. Gabriel , Menon, Syamkumar M. Divakara, Tan, Nigel S. , Vivekanantham, Hari , Pandya, Tanvi, Cunningham, Jennifer , Gula, Lorne J. , Wong, Jorge , Amit, Guy , Scheinman, Melvin M. , Ackerman, Michael J. , Priori, Silvia G. , Sacher, Frédéric , Nof, Eyal , Glikson, Michael , Wilde, Arthur A.M. , Jensen, Henrik Kjærulf , Chen, S.R. Wayne , Roberts, Jason D. , Jensen, Henrik Kjærulf , Mazzanti, Andrea , Priori, Silvia , Dadon, Ziv , Ormerod, Julian O.M. , Tadros, Rafik , Christiansen, Morten Krogh , Steinberg, Christian , Giudicessi, John R. , Werf, Christian van der , Nazer, Babak , Krahn, Andrew D. , Gollob, Michael H. , Healey, Jeff S. , Glikson, Michael , Watkins, Hugh , Postema, Pieter G. , Belhassen, Bernard

JAMA | June 20, 2024 | Volume: 332 | Issue: 3 | Pages: 204

10.1001/jama.2024.8599 Get It

Importance Sudden death and cardiac arrest frequently occur without explanation, even after a thorough clinical evaluation. Calcium release deficiency syndrome (CRDS), a life-threatening genetic arrhythmia syndrome, is undetectable with standard testing and leads to unexplained cardiac arrest. Objective To explore the cardiac repolarization response on an electrocardiogram after brief tachycardia and a pause as a clinical diagnostic test for CRDS. Design, Setting, and Participants An international, multicenter, case-control study including individual cases of CRDS, 3 patient control groups (individuals with suspected supraventricular tachycardia; survivors of unexplained cardiac arrest [UCA]; and individuals with genotype-positive catecholaminergic polymorphic ventricular tachycardia [CPVT]), and genetic mouse models (CRDS, wild type, and CPVT were used to define the cellular mechanism) conducted at 10 centers in 7 countries. Patient tracings were recorded between June 2005 and December 2023, and the analyses were performed from April 2023 to December 2023. Intervention Brief tachycardia and a subsequent pause (either spontaneous or mediated through cardiac pacing). Main Outcomes and Measures Change in QT interval and change in T-wave amplitude (defined as the difference between their absolute values on the postpause sinus beat and the last beat prior to tachycardia). Results Among 10 case patients with CRDS, 45 control patients with suspected supraventricular tachycardia, 10 control patients who experienced UCA, and 3 control patients with genotype-positive CPVT, the median change in T-wave amplitude on the postpause sinus beat (after brief ventricular tachycardia at ≥150 beats/min) was higher in patients with CRDS ( P < .001). The smallest change in T-wave amplitude was 0.250 mV for a CRDS case patient compared with the largest change in T-wave amplitude of 0.160 mV for a control patient, indicating 100% discrimination. Although the median change in QT interval was longer in CRDS cases ( P = .002), an overlap between the cases and controls was present. The genetic mouse models recapitulated the findings observed in humans and suggested the repolarization response was secondary to a pathologically large systolic release of calcium from the sarcoplasmic reticulum. Conclusions and Relevance There is a unique repolarization response on an electrocardiogram after provocation with brief tachycardia and a subsequent pause in CRDS cases and mouse models, which is absent from the controls. If these findings are confirmed in larger studies, this easy to perform maneuver may serve as an effective clinical diagnostic test for CRDS and become an important part of the evaluation of cardiac arrest.
Outcome and safety of intraoperative defibrillation testing during device replacement: the Simpler trial
Nof, Eyal , Rav, Moshe , Beinart, Roy, Kutyifa, Valentina , Regev, Ehud , Biffi, Mauro , Cha, Yong‐Mei , Ovdat, Tal , Klempfner, Robert , Glikson, Michael , Goldenberg, Ilan , Milman, Anat , Rav Acha, Moshe , Beinart, Roy , Kutyifa, Valentina , Merkely, Béla , Regev, Ehud , Biffi, Mauro , Cha, Yong-Mei , Ovdat, Tal , Glikson, Michael

EP Europace | January 13, 2023 | Volume: 25 | Issue: 3 | Pages: 956-960

10.1093/europace/euac282 Get It

AbstractAimsIntraoperative defibrillation testing (DT) during implant or replacement of implantable cardioverter-defibrillators (ICDs) has been a matter of debate for many years. This debate was put to rest by the Simple and Nordic ICD trials, and the practice of testing during new implantations has essentially been almost abandoned. Old registries demonstrated an increased incidence of significant findings in DT during replacements. The aim of the present study was to evaluate frequency of significant findings and safety of DT in subjects undergoing device replacement.Methods and resultsA prospective observational multi-centre study included consecutive patients undergoing ICD generator replacement. The primary outcome was a failure to terminate induced ventricular fibrillation (VF) with a single shock 10 J below the maximal capacity of the device. Secondary outcomes included complications of DT. Patients were followed-up at 1- and 6-months post-procedure. A total of 92 patients were eligible, and consented to the study, of which 84 underwent DT during battery replacement. The median age was 68 years and 79.8% were males. Induction of VF was successful in 84 patients as was a successful conversion on the first attempt in all. There were no procedure-related complications. During follow up one patient had two appropriate ICD shock events. In four patients, ICD programming was changed. None suffered inappropriate shock. There was no evidence of lead malfunction. Two deaths occurred, none of which was related to arrhythmia.ConclusionThe present study found DT was not associated with complications in patients undergoing ICD generator replacement but produced no clinically important information.
Intraoperative defibrillation testing during replacements of implantable cardioverter-defibrillators: The Simpler trial
Nof, Eyal , Regev, Ehud , Rav, Moshe , Kutyifa, Valentina, Merkely, B, Biffi, M, Cha, YM, Ovdat, T, Klempfner, R., Glikson, Michael , Milman, Anat , Beinart, Roy , Kutyifa, Valentina , Biffi, Mauro , Ovdat, T, Glikson, Michael

EP Europace | May 19, 2022 | Volume: 24 | Issue: Supplement_1 | Pages: No page available

10.1093/europace/euac053.461 Get It

Abstract Funding Acknowledgements Type of funding sources: Foundation. Main funding source(s): Maurice Kahn Foundation via the Mayo- Sheba Collaboration Fund. Background The need for intraoperative defibrillation testing (DFT) during implant and/or replacement of implantable cardioverter-defibrillators (ICDs) has been a matter of debate for many years. This debate was put to rest by the Simple and the Nordic ICD trials, and the practice of testing during new implantations has practically been nearly abandoned. Nevertheless, induction of VF for testing purposes (VFT) may still have an important role in selective populations at risk for defibrillation failure, who were not included in the SIMPLE and Nordic trials. One such population includes those who undergo device replacements. Old registries demonstrated an increased incidence of significant findings in VFT during replacements. In the present study, we sought to test this observation. Objectives Evaluate frequency of significant findings and the safety of VFT in subjects undergoing device replacement. Methods A prospective observational multi-center study of VFT included consecutive patients undergoing ICD generator replacement in 5 centers in Israel, Europe, and the US. All centers followed the same VFT protocol. The primary outcome was defined as failure to terminate induced VF with a single shock at 10 Joules below the maximal capacity of the device. Secondary outcomes included complications of VFT. Patients were followed-up at 1 month and 6 months post-procedure. Data collection included documentation of any peri-operative complications and clinical endpoints (occurrence of appropriate shock, inappropriate shocks, lead failure, need for re-intervention, and infection). Results A total of 92 patients were eligible, and consented for the study, of which 84 underwent DFT during battery replacement. The median age was 68 years and 79.8% were male subjects. Induction of VF was successful in all 84 patients as well as VFT with a successful conversion on first attempt. During follow up one patient had two appropriate ICD shock events. In four patients, the ICD programming was changed. None suffered an inappropriate shock. There was no evidence of lead malfunction. A total of two deaths occurred, none of which were related to the device. Conclusion The present study found VFT was not associated with complications in patients undergoing ICD/CRTD generator replacement but produced no clinically important information.
Subcutaneous ICD combined with VT ablation for the secondary prevention of sudden cardiac death: pilot data from the prospective multinational SICD-VTAbl study
Sacher, F., Mulpuru, Siva K. , Friedman, Paul A. , Meyer, Christopher , Benshushan, Abraham, Tiefenbrun, Nava L., Nof, Eyal , Investigators, The SICD-VTAbl, Goldenberg, Ilan , Maury, Philippe , Clémenty, Nicolas , Huang, David T. , Meyer, C, Benshushan, A D, Tiefenbrun, Nava, Investigators, The SICD-VTAbl

European Heart Journal | October 20, 2021 | Volume: 42 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehab724.0399 Get It

Abstract Background The aim of the Subcutaneous ICD Combined with Ventricular Tachycardia Ablation (SICD-VTAbl) Study is to provide preliminary data on the safety and efficacy of a management strategy that incorporates S-ICD implantation and VT ablation among patients with a secondary prevention indication for an ICD. We hypothesize that VT ablation for the prevention of monomorphic VT recurrence combined with S-ICD implantation for termination of life-threatening VT/VF is safe, while reducing the need for device interventions and systemic complications associated with conventional transvenous ICD implantation for secondary prevention. Methods SICD-VTAbl is an uncontrolled, prospective, multinational observational study, conducted in France, Germany, US (Rochester NY, and Rochester MN) and coordinated in Israel. We aim to prospectively enroll 30 patients presenting with scar-related VT/VF who will undergo VT ablation/substrate modification followed by S-ICD implantation. The primary endpoint is the first occurrence of S-ICD therapy (appropriate and inappropriate). Secondary endpoints include separate occurrence of appropriate and inappropriate ICD therapies, peri-procedural complications, and adverse clinical outcomes. Results We provide clinical, arrhythmia, and outcome data on the first 15 patients enrolled in the SICD-VTAbl Study through February 2021. Mean age was 59±12 years, 78% were males, 60% had New York Heart Association (NYHA) Class ≥II symptoms, 20% had renal insufficiency, and 33% were treated with an antiarrhythmic medication (all amiodarone). Periprocedural, arrhythmia, and long-term outcome data are provided in Table 1. There were no major complications associated with the VT ablation and the S-ICD implantation procedures. During a median follow-up of 6 months (interquartile range: 2–12 months), 2 patients (13%) received S-ICD therapy: one patient (7%) experienced VF terminated by the S-ICD and one patient experienced a single episode of inappropriate S-ICD therapy. Adverse events during follow-up, unrelated to study procedures, occurred in 3 patients (20%): hospitalization for heart failure exacerbation (N=1) and non-cardiovascular hospitalizations (N=2). None of the patients died during follow-up (Table 1). Conclusions Our preliminary data from the SICD-VTAbl Study suggest that a management approach that incorporates VT ablation followed by S-ICD implantation is safe and may lead to improved arrhythmia and clinical outcomes in patients presenting with a secondary prevention indication for an ICD. Funding Acknowledgement Type of funding sources: Other. Main funding source(s): Research grant to Sheba Medical Center from Boston Scientific