Back to Authors

Clémenty, Nicolas

0000-0002-7415-0787

Mayo Clinic

Clinique du Millénaire

Citations 6

Infection management in the extravascular implantable cardioverter defibrillator: experience from the EV ICD Pivotal study
Murgatroyd, Francis , Manlucu, Jaimie , Knight, Bradley P. , Leclercq, Christophe , Birgersdotter‐Green, Ulrika , Mattioni, Thomas A., Sholevar, Darius P., Hersi, Ahmad , Wiggenhorn, Christopher, Friedman, Paul A. , Knight, Bradley P , Clémenty, Nicolas , Crozier, Ian , Boersma, Lucas V.A.

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.746 Get It

Abstract Background The extravascular implantable cardioverter defibrillator (EV ICD) has recently emerged as an option for guideline indicated ICD patients. Results from the EV ICD Pilot and Pivotal studies demonstrated that the device can provide safe and effective therapy through chronic follow up. Lead placement outside the vasculature has the potential to reduce systemic infections. Infection occurrence and management details from the Pivotal are reported. Purpose To report on details of infection occurrence and management from the EV ICD Pivotal study. Methods The EV ICD Pivotal study was an international, prospective, single-arm, premarket clinical study. Patients with a class I or IIa indication for a single-chamber ICD per ESC or ACC/AHA/HRS guidelines were enrolled. Results In the EV ICD Pivotal study, 316 patients had an implant attempt, (74.7% male, age 53.8±13.1 years, 82% primary prevention, LVEF of 38.9%±15.4%, and NYHA Class I [23.7%] or II/III [65.5%]), of which 15 had a system or procedure-related infection (4.7%, 9 - 737 days post-implant) through an average 16.2 months follow-up. Of these infections, 8 were classified as major complications, 3 as minor, and 4 as observations. Most (n=9) infections were addressed through medication with or without wound care (2.8% of patients) while 6 (1.9% of patients) resulted in system removal. There was a single lead-related infection addressed through system explant. However, there were no reports of mediastinitis, sepsis, or endocarditis. No system removal resulted in sequelae. Conclusions Infection rates observed in the EV ICD Pivotal study were similar to those reported in the subcutaneous implantable cardioverter defibrillator. The results from this study support that EV ICD related infections are treatable with antibiotic therapy or system removal. No system or procedure-related systemic infections such as mediastinitis, sepsis, or endocarditis have been reported in the Pivotal study.
Performance and Safety of the Extravascular Implantable Cardioverter Defibrillator Through Long-Term Follow-Up: Final Results From the Pivotal Study
Friedman, Paul A. , Murgatroyd, Francis , Boersma, Lucas V.A. , Manlucu, Jaimie , Knight, Bradley P. , Leclercq, Christophe , Amin, Anish K. , Birgersdotter‐Green, Ulrika , Chan, Joseph Yat Sun , Engel, Gregory , Carvajal, Ignacio Muñoz , Sagi, Venkata, Johansen, Jens Brock , Steinwender, Clemens , Hounshell, Troy , Abben, Richard, Thompson, Amy , Wiggenhorn, Christopher, Willey, Sarah, Investigators, on behalf of the Extravascular ICD Pivotal Study, Friedman, Paul A , Leclercq, Christophe , Merkely, Béla , Birgersdotter-Green, Ulrika Maria , Chan, Joseph Yat Sun , Biffi, Mauro , Knops, Reinoud Elwin , Muñoz Carvajal, Ignacio , Epstein, Laurence M , Johansen, Jens Brock , Sterliński, Maciej , Steinwender, Clemens , Hounshell, Troy , Abben, Richard , Thompson, Amy E , Crozier, Ian , Knight, Bradley P , Boersma, Lucas , Clémenty, Nicolas , Biffi, Mauro , Engel, Gregory, Epstein, Laurence M. , Zhang, Yan , Crozier, Ian , Investigators, on behalf of the Extravascular ICD Pivotal Study

Circulation | September 27, 2024 | Volume: 151 | Issue: 4 | Pages: 322-332

10.1161/circulationaha.124.071795 Get It

BACKGROUND: Substernal lead placement of the extravascular implantable cardioverter defibrillator (EV ICD) permits both defibrillation at thresholds similar to those seen with transvenous implantable cardioverter defibrillators and effective anti-tachycardia pacing (ATP) while avoiding the vasculature and associated complications. The global Pivotal study has shown the EV ICD system to be safe and effective through 6 months, but long-term experience has yet to be published. Our aim was to report the performance and safety of the EV ICD system throughout the study. METHODS: The EV ICD Pivotal study was a prospective, global, single-arm, premarket clinical study. Individuals with a Class I or IIa indication for a single-chamber implantable cardioverter defibrillator per guidelines were enrolled. Freedom from major system- or procedure-related complications and appropriate and inappropriate therapy rates were assessed through 3 years with the Kaplan-Meier method. ATP success was calculated from simple proportions. RESULTS: An implantation was attempted in 316 patients (25.3% female; 53.8±13.1 years of age; 81.6% primary prevention; left ventricular ejection fraction, 38.9±15.4%). Of 299 patients with a successful implantation, 24 experienced 82 spontaneous arrhythmic episodes that were appropriately treated with ATP only (38, 46.3%), shock only (34, 41.5%), or both (10, 12.2%) for a Kaplan-Meier–estimated rate of first any appropriate therapy of 9.2% at 3 years. ATP was successful in 77.1% (37/48) of episodes, and ATP use significantly increased from discharge to last follow-up visit ( P <0.0001). Shock therapy was successful in 100% (27/27) of discrete, spontaneous ventricular arrhythmias. The inappropriate shock rates at 1 and 3 years were 9.8% and 17.5%, respectively, with P-wave oversensing the predominant cause. No major intraprocedural complications were reported, and the estimated freedom from system- or procedure-related major complications was 91.9% at 1 year and 89.0% at 3 years. The most common major complications were lead dislodgement (10 events; n=9 patients, 2.8%), postoperative wound or device pocket infection (n=8, 2.5%), and device inappropriate shock delivery (n=4, 1.3%). Twenty-four system revisions were performed as a result of major complications related to the EV ICD system or procedure. CONCLUSIONS: From implantation to study completion, the EV ICD Pivotal study demonstrated that a single integrated system with an extravascular lead placed in the substernal space maintains high ATP success, effective defibrillation, and a consistent safety profile. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04060680.
Leadless pacemakers at 5-year follow-up: the Micra transcatheter pacing system post-approval registry
Garweg, Christophe , Clementy, Nicolas, Al-Samadi, Faisal, Iacopino, Saverio , Roberts, Paul R. , Johansen, Jens Brock , Vinolas-Prat, X., Cha, Yong‐Mei , Grubman, Eric , Bordachar, Pierre , Fagan, Dedra H. , Piccini, Jonathan P. , El-Chami, Mikhael F , Garweg, Christophe , Johansen, Jens Brock , Cha, Yong-Mei , Stromberg, Kurt , El‐Chami, Mikhael F. , Clémenty, Nicolas , Martínez‐Sande, José Luis , Tondo, Claudio , Stromberg, Kurt

European Heart Journal | February 9, 2024 | Volume: 45 | Issue: 14 | Pages: 1241-1251

10.1093/eurheartj/ehae101 Get It

Abstract Background and Aims Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. Methods All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine–Gray competing risk models. Results 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6–64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%–5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36–.61; P &lt; .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%–6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P &lt; .001). Conclusions Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.
Chronic safety and performance of the extravascular ICD: results from the global EV ICD Pivotal study
Friedman, Paul A. , Murgatroyd, Francis , Manlucu, Jaimie , Leclercq, Christophe , Amin, Anish K. , Birgersdotter‐Green, Ulrika , Wiggenhorn, Christopher, Boersma, Lucas V.A. , Knight, Bradley P. , Clémenty, Nicolas , Merkely, Béla , Chan, J Y S, Biffi, Mauro , Knops, Reinoud Elwin , Crozier, Ian

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.682 Get It

Abstract Background Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death in patients at high risk for ventricular arrhythmias, but conventional systems carry a risk of transvenous (TV) lead-related complications. The novel extravascular ICD (EV ICD) may reduce some of these complications, while offering anti-tachycardia pacing (ATP), pause prevention pacing, and a device of similar size and projected battery longevity as a TV ICD, by placing a lead substernally. The EV ICD Pivotal study demonstrated EV ICD safety and performance for termination of ventricular arrythmias at 6 months. Longer-term performance is unknown. Purpose To report the chronic safety and performance of the EV ICD system. Methods The extravascular implantable cardioverter defibrillator (EV ICD) Pivotal study was a prospective, international, single-arm, premarket clinical study. Patients with a class I or IIa indication for a single-chamber ICD per ESC or ACC/AHA/HRS guidelines were enrolled. Freedom from major system- and/or procedure-related complications at 18 mo was evaluated, as well as conversion of arrhythmias by anti-tachycardia pacing (ATP) or shock through all available follow up. Rates of ATP success were evaluated using the generalized estimating equation (GEE) and simple proportions. Results Implantation was attempted in 316 patients: 74.7% male, age 53.8±13.1 years, 82% primary prevention, left ventricular ejection fraction of 38.9%±15.4%, and New York Heart Association Class I (23.4%) or II/III (65.5%). Of 299 implanted patients (average follow up 16.2±7.2 mo), 19 experienced 80 spontaneous, appropriately treated arrhythmic episodes: 37 treated by ATP, 15 by ATP and shock, and 28 by shock alone with a Kaplan-Meier (KM) estimated 6.8% of patients experiencing appropriate therapy by 18 mo (Figure). Of discrete episodes treated with shock, 21/21 (100%) were successfully terminated. ATP was delivered in 12 patients, successfully treating 35/52 episodes (67.3%; GEE adjusted 59.0%). Inappropriate shocks occurred in 35 patients through all follow up, with a rate of 10.2% at 1 year. The KM estimate of freedom from major EV ICD system-or procedure-related complications rate through 18 mo was 91.9% (95% CI: 88.2% to 94.4%). The most common event was lead dislodgment (10 events in 9 patients) identified 0 to 120 days post-implant, predominantly due to anchoring technique. Conclusion The safety and effectiveness of a novel EV ICD system with a substernal lead extends through chronic follow up. Shocks were avoided in nearly half of all spontaneous episodes because of the availability of ATP.Figure
Subcutaneous ICD combined with VT ablation for the secondary prevention of sudden cardiac death: pilot data from the prospective multinational SICD-VTAbl study
Sacher, F., Mulpuru, Siva K. , Friedman, Paul A. , Meyer, Christopher , Benshushan, Abraham, Tiefenbrun, Nava L., Nof, Eyal , Investigators, The SICD-VTAbl, Goldenberg, Ilan , Maury, Philippe , Clémenty, Nicolas , Huang, David T. , Meyer, C, Benshushan, A D, Tiefenbrun, Nava, Investigators, The SICD-VTAbl

European Heart Journal | October 20, 2021 | Volume: 42 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehab724.0399 Get It

Abstract Background The aim of the Subcutaneous ICD Combined with Ventricular Tachycardia Ablation (SICD-VTAbl) Study is to provide preliminary data on the safety and efficacy of a management strategy that incorporates S-ICD implantation and VT ablation among patients with a secondary prevention indication for an ICD. We hypothesize that VT ablation for the prevention of monomorphic VT recurrence combined with S-ICD implantation for termination of life-threatening VT/VF is safe, while reducing the need for device interventions and systemic complications associated with conventional transvenous ICD implantation for secondary prevention. Methods SICD-VTAbl is an uncontrolled, prospective, multinational observational study, conducted in France, Germany, US (Rochester NY, and Rochester MN) and coordinated in Israel. We aim to prospectively enroll 30 patients presenting with scar-related VT/VF who will undergo VT ablation/substrate modification followed by S-ICD implantation. The primary endpoint is the first occurrence of S-ICD therapy (appropriate and inappropriate). Secondary endpoints include separate occurrence of appropriate and inappropriate ICD therapies, peri-procedural complications, and adverse clinical outcomes. Results We provide clinical, arrhythmia, and outcome data on the first 15 patients enrolled in the SICD-VTAbl Study through February 2021. Mean age was 59±12 years, 78% were males, 60% had New York Heart Association (NYHA) Class ≥II symptoms, 20% had renal insufficiency, and 33% were treated with an antiarrhythmic medication (all amiodarone). Periprocedural, arrhythmia, and long-term outcome data are provided in Table 1. There were no major complications associated with the VT ablation and the S-ICD implantation procedures. During a median follow-up of 6 months (interquartile range: 2–12 months), 2 patients (13%) received S-ICD therapy: one patient (7%) experienced VF terminated by the S-ICD and one patient experienced a single episode of inappropriate S-ICD therapy. Adverse events during follow-up, unrelated to study procedures, occurred in 3 patients (20%): hospitalization for heart failure exacerbation (N=1) and non-cardiovascular hospitalizations (N=2). None of the patients died during follow-up (Table 1). Conclusions Our preliminary data from the SICD-VTAbl Study suggest that a management approach that incorporates VT ablation followed by S-ICD implantation is safe and may lead to improved arrhythmia and clinical outcomes in patients presenting with a secondary prevention indication for an ICD. Funding Acknowledgement Type of funding sources: Other. Main funding source(s): Research grant to Sheba Medical Center from Boston Scientific