Abstract Background and Aims Stroke and systemic embolism are recognized but poorly characterized complications of atrial fibrillation (AF) and left atrial flutter (AFL) catheter ablation. Their incidence, outcomes, and procedural associations remain insufficiently defined. Methods Retrospective global registry was initiated by the European Heart Rhythm Association Scientific Committee. A secure database captured data from ablation centres worldwide on general AF and left AFL ablation activity, as well as detailed information on patients with symptomatic embolic events between 2017 and 2024. Results Overall, 204 centres reported 335 743 ablation procedures and 550 embolic events (incidence 0.16%). Centre-level rate ranged from 0% to 3.1%. Most events were cerebral (94%), followed by peripheral (5%), and combined (1%). Coronary air embolism accounted for 62% of all peripheral events. Intraprocedural events occurred in 93 patients (17%), within 72 h in 357 (78%) and beyond 72 h in 100 (22%); 128 cases (23%) were diagnosed after hospital discharge. Nonparoxysmal AF (0.23% vs 0.15%; P < .001), centre experience, and ablation energy source (radiofrequency, 0.16%; cryoballoon, 0.16%; pulsed field ablation, 0.25%; laserballoon, 0.88%; P < .001) were associated with embolic risk. Median NIHSS score after stroke was 4 (interquartile range, 2–9). Three-month follow-up was available for 518 patients with embolism (95%): 181 (35%) had sequelae and 16 (3%) died. Conclusions Symptomatic embolic events are infrequent but associated with significant morbidity and mortality. Most events occur early, though a substantial proportion arise later. Higher event rates were observed with laser and possibly with pulsed field ablation. A greater centre experience was associated with a lower embolism incidence.
Performance and Safety of the Extravascular Implantable Cardioverter Defibrillator Through Long-Term Follow-Up: Final Results From the Pivotal Study
BACKGROUND: Substernal lead placement of the extravascular implantable cardioverter defibrillator (EV ICD) permits both defibrillation at thresholds similar to those seen with transvenous implantable cardioverter defibrillators and effective anti-tachycardia pacing (ATP) while avoiding the vasculature and associated complications. The global Pivotal study has shown the EV ICD system to be safe and effective through 6 months, but long-term experience has yet to be published. Our aim was to report the performance and safety of the EV ICD system throughout the study. METHODS: The EV ICD Pivotal study was a prospective, global, single-arm, premarket clinical study. Individuals with a Class I or IIa indication for a single-chamber implantable cardioverter defibrillator per guidelines were enrolled. Freedom from major system- or procedure-related complications and appropriate and inappropriate therapy rates were assessed through 3 years with the Kaplan-Meier method. ATP success was calculated from simple proportions. RESULTS: An implantation was attempted in 316 patients (25.3% female; 53.8±13.1 years of age; 81.6% primary prevention; left ventricular ejection fraction, 38.9±15.4%). Of 299 patients with a successful implantation, 24 experienced 82 spontaneous arrhythmic episodes that were appropriately treated with ATP only (38, 46.3%), shock only (34, 41.5%), or both (10, 12.2%) for a Kaplan-Meier–estimated rate of first any appropriate therapy of 9.2% at 3 years. ATP was successful in 77.1% (37/48) of episodes, and ATP use significantly increased from discharge to last follow-up visit ( P <0.0001). Shock therapy was successful in 100% (27/27) of discrete, spontaneous ventricular arrhythmias. The inappropriate shock rates at 1 and 3 years were 9.8% and 17.5%, respectively, with P-wave oversensing the predominant cause. No major intraprocedural complications were reported, and the estimated freedom from system- or procedure-related major complications was 91.9% at 1 year and 89.0% at 3 years. The most common major complications were lead dislodgement (10 events; n=9 patients, 2.8%), postoperative wound or device pocket infection (n=8, 2.5%), and device inappropriate shock delivery (n=4, 1.3%). Twenty-four system revisions were performed as a result of major complications related to the EV ICD system or procedure. CONCLUSIONS: From implantation to study completion, the EV ICD Pivotal study demonstrated that a single integrated system with an extravascular lead placed in the substernal space maintains high ATP success, effective defibrillation, and a consistent safety profile. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04060680.
Efficacy and Safety of an Extravascular Implantable Cardioverter–Defibrillator