Back to Authors

Chan, Joseph Yat Sun

https://orcid.org/0000-0002-3356-4836

Mayo Clinic

Chinese University of Hong Kong

Citations 2

Performance and Safety of the Extravascular Implantable Cardioverter Defibrillator Through Long-Term Follow-Up: Final Results From the Pivotal Study
Friedman, Paul A. , Murgatroyd, Francis , Boersma, Lucas V.A. , Manlucu, Jaimie , Knight, Bradley P. , Leclercq, Christophe , Amin, Anish K. , Birgersdotter‐Green, Ulrika , Chan, Joseph Yat Sun , Engel, Gregory , Carvajal, Ignacio Muñoz , Sagi, Venkata, Johansen, Jens Brock , Steinwender, Clemens , Hounshell, Troy , Abben, Richard, Thompson, Amy , Wiggenhorn, Christopher, Willey, Sarah, Investigators, on behalf of the Extravascular ICD Pivotal Study, Friedman, Paul A , Leclercq, Christophe , Merkely, Béla , Birgersdotter-Green, Ulrika Maria , Chan, Joseph Yat Sun , Biffi, Mauro , Knops, Reinoud Elwin , Muñoz Carvajal, Ignacio , Epstein, Laurence M , Johansen, Jens Brock , Sterliński, Maciej , Steinwender, Clemens , Hounshell, Troy , Abben, Richard , Thompson, Amy E , Crozier, Ian , Knight, Bradley P , Boersma, Lucas , Clémenty, Nicolas , Biffi, Mauro , Engel, Gregory, Epstein, Laurence M. , Zhang, Yan , Crozier, Ian , Investigators, on behalf of the Extravascular ICD Pivotal Study

Circulation | September 27, 2024 | Volume: 151 | Issue: 4 | Pages: 322-332

10.1161/circulationaha.124.071795 Get It

BACKGROUND: Substernal lead placement of the extravascular implantable cardioverter defibrillator (EV ICD) permits both defibrillation at thresholds similar to those seen with transvenous implantable cardioverter defibrillators and effective anti-tachycardia pacing (ATP) while avoiding the vasculature and associated complications. The global Pivotal study has shown the EV ICD system to be safe and effective through 6 months, but long-term experience has yet to be published. Our aim was to report the performance and safety of the EV ICD system throughout the study. METHODS: The EV ICD Pivotal study was a prospective, global, single-arm, premarket clinical study. Individuals with a Class I or IIa indication for a single-chamber implantable cardioverter defibrillator per guidelines were enrolled. Freedom from major system- or procedure-related complications and appropriate and inappropriate therapy rates were assessed through 3 years with the Kaplan-Meier method. ATP success was calculated from simple proportions. RESULTS: An implantation was attempted in 316 patients (25.3% female; 53.8±13.1 years of age; 81.6% primary prevention; left ventricular ejection fraction, 38.9±15.4%). Of 299 patients with a successful implantation, 24 experienced 82 spontaneous arrhythmic episodes that were appropriately treated with ATP only (38, 46.3%), shock only (34, 41.5%), or both (10, 12.2%) for a Kaplan-Meier–estimated rate of first any appropriate therapy of 9.2% at 3 years. ATP was successful in 77.1% (37/48) of episodes, and ATP use significantly increased from discharge to last follow-up visit ( P <0.0001). Shock therapy was successful in 100% (27/27) of discrete, spontaneous ventricular arrhythmias. The inappropriate shock rates at 1 and 3 years were 9.8% and 17.5%, respectively, with P-wave oversensing the predominant cause. No major intraprocedural complications were reported, and the estimated freedom from system- or procedure-related major complications was 91.9% at 1 year and 89.0% at 3 years. The most common major complications were lead dislodgement (10 events; n=9 patients, 2.8%), postoperative wound or device pocket infection (n=8, 2.5%), and device inappropriate shock delivery (n=4, 1.3%). Twenty-four system revisions were performed as a result of major complications related to the EV ICD system or procedure. CONCLUSIONS: From implantation to study completion, the EV ICD Pivotal study demonstrated that a single integrated system with an extravascular lead placed in the substernal space maintains high ATP success, effective defibrillation, and a consistent safety profile. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04060680.
Comprehensive analysis of substernal lead removal: experience from EV ICD Pilot, Pivotal, and Continued Access Studies
Sagi, Venkata, Murgatroyd, Francis , Boersma, Lucas V.A. , Manlucu, Jaimie , Knight, Bradley P. , Leclercq, Christophe , Amin, Anish K. , Birgersdotter‐Green, Ulrika , Chan, Joseph Yat Sun , Roukoz, Henri , Denman, R. , Wiggenhorn, Christopher, Holmes, Thomas R, Lulic, Thomas, Friedman, Paul A. , Biffi, Mauro , Haqqani, Haris , Denman, Russell , Friedman, Paul A , Crozier, Ian , Knight, Bradley P , Boersma, Lucas , Amin, Anish, Biffi, Mauro , Holmes, Thomas R, Crozier, Ian

Europace | August 30, 2024 | Volume: 26 | Issue: 9 | Pages: No page available

10.1093/europace/euae225 Get It

Abstract Aims The extravascular implantable cardioverter-defibrillator (EV ICD) has been shown to be safe and effective for patients at risk of sudden cardiac death, but little is known about EV ICD lead removal in humans. This analysis aimed to characterize the EV ICD lead removal experience thus far. Methods and results This was a retrospective analysis of lead removals from the EV ICD Pilot, Pivotal, and Continued Access Studies. Patients with a successful EV ICD implant who underwent lead removal were included. The main objective was lead removal success. Ancillary objectives included characterizing technique used, procedure complications, and reimplantation status. An EV ICD system was successfully implanted in 347 patients across the 3 studies (25.9% female; 53.4 ± 13.3 years; left ventricular ejection fraction: 39.7 ± 15.9). Of these patients, 29 (8.4%) underwent lead removal with a mean lead dwell time of 12.6 ± 14.3 months (0.2–58.4). The main reason for lead removal was lead dislodgement (n = 9, 31.0%). Lead removal was successful in 27/29 (93.1%) cases [100% (19/19) success rate &lt;1 year and 80% (8/10) success rate &gt;1 year post-implant]. Simple traction was used in 22/26 (84.6%) and extraction tools in 4/26 (15.4%) successful cases where technique was known. No complications were reported for any of the removal procedures. All 11 EV ICD reimplant attempts were successful. Conclusion Complete removal of the EV ICD lead was successful in 93.1% of cases, and simple traction was sufficient in most instances. Based on these results, lead removal from the substernal space was safe and achievable up to 3 years post-implant.