BACKGROUND: Substernal lead placement of the extravascular implantable cardioverter defibrillator (EV ICD) permits both defibrillation at thresholds similar to those seen with transvenous implantable cardioverter defibrillators and effective anti-tachycardia pacing (ATP) while avoiding the vasculature and associated complications. The global Pivotal study has shown the EV ICD system to be safe and effective through 6 months, but long-term experience has yet to be published. Our aim was to report the performance and safety of the EV ICD system throughout the study. METHODS: The EV ICD Pivotal study was a prospective, global, single-arm, premarket clinical study. Individuals with a Class I or IIa indication for a single-chamber implantable cardioverter defibrillator per guidelines were enrolled. Freedom from major system- or procedure-related complications and appropriate and inappropriate therapy rates were assessed through 3 years with the Kaplan-Meier method. ATP success was calculated from simple proportions. RESULTS: An implantation was attempted in 316 patients (25.3% female; 53.8±13.1 years of age; 81.6% primary prevention; left ventricular ejection fraction, 38.9±15.4%). Of 299 patients with a successful implantation, 24 experienced 82 spontaneous arrhythmic episodes that were appropriately treated with ATP only (38, 46.3%), shock only (34, 41.5%), or both (10, 12.2%) for a Kaplan-Meier–estimated rate of first any appropriate therapy of 9.2% at 3 years. ATP was successful in 77.1% (37/48) of episodes, and ATP use significantly increased from discharge to last follow-up visit ( P <0.0001). Shock therapy was successful in 100% (27/27) of discrete, spontaneous ventricular arrhythmias. The inappropriate shock rates at 1 and 3 years were 9.8% and 17.5%, respectively, with P-wave oversensing the predominant cause. No major intraprocedural complications were reported, and the estimated freedom from system- or procedure-related major complications was 91.9% at 1 year and 89.0% at 3 years. The most common major complications were lead dislodgement (10 events; n=9 patients, 2.8%), postoperative wound or device pocket infection (n=8, 2.5%), and device inappropriate shock delivery (n=4, 1.3%). Twenty-four system revisions were performed as a result of major complications related to the EV ICD system or procedure. CONCLUSIONS: From implantation to study completion, the EV ICD Pivotal study demonstrated that a single integrated system with an extravascular lead placed in the substernal space maintains high ATP success, effective defibrillation, and a consistent safety profile. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04060680.
Comprehensive analysis of substernal lead removal: experience from EV ICD Pilot, Pivotal, and Continued Access Studies
Abstract Aims The extravascular implantable cardioverter-defibrillator (EV ICD) has been shown to be safe and effective for patients at risk of sudden cardiac death, but little is known about EV ICD lead removal in humans. This analysis aimed to characterize the EV ICD lead removal experience thus far. Methods and results This was a retrospective analysis of lead removals from the EV ICD Pilot, Pivotal, and Continued Access Studies. Patients with a successful EV ICD implant who underwent lead removal were included. The main objective was lead removal success. Ancillary objectives included characterizing technique used, procedure complications, and reimplantation status. An EV ICD system was successfully implanted in 347 patients across the 3 studies (25.9% female; 53.4 ± 13.3 years; left ventricular ejection fraction: 39.7 ± 15.9). Of these patients, 29 (8.4%) underwent lead removal with a mean lead dwell time of 12.6 ± 14.3 months (0.2–58.4). The main reason for lead removal was lead dislodgement (n = 9, 31.0%). Lead removal was successful in 27/29 (93.1%) cases [100% (19/19) success rate <1 year and 80% (8/10) success rate >1 year post-implant]. Simple traction was used in 22/26 (84.6%) and extraction tools in 4/26 (15.4%) successful cases where technique was known. No complications were reported for any of the removal procedures. All 11 EV ICD reimplant attempts were successful. Conclusion Complete removal of the EV ICD lead was successful in 93.1% of cases, and simple traction was sufficient in most instances. Based on these results, lead removal from the substernal space was safe and achievable up to 3 years post-implant.
Substernal lead removal: experience from the EV ICD pivotal study
Abstract Background The extravascular implantable cardioverter defibrillator (EV ICD) has recently emerged as a new option for guideline indicated ICD patients. Previous study results from the EV ICD Pilot and Pivotal studies have demonstrated that the device can provide safe and effective therapy through chronic follow up. However, less has been reported regarding EV ICD lead removal. Purpose To report on the experience of lead removal in the EV ICD Pivotal Study. Methods The EV ICD Pivotal study was an international, prospective, single-arm, premarket clinical study. Patients with a class I or IIa indication for a single-chamber ICD per ESC or ACC/AHA/HRS guidelines were enrolled. Lead removal summary data was reported. Results Of 316 patients with an implant attempt, (74.7% male, age 53.8±13.1 years, 82% primary prevention, LVEF of 38.9%±15.4%, and NYHA Class I [23.7%] or II/III [65.5%]) 299 were fully implanted; 17 (5.7%) of which had a lead removal procedure (14–752 days post-implant, at 13 sites) with 3 of them having been implanted for more than 1 year. Reasons for lead removal were lead dislodgement (n=7), infection (n=5), high impedance alert due to lead fracture (n=2), pacing indication (n=1), cardiac transplant (n=1), or scheduled sternotomy (n=1). New EV ICD leads were placed in 7/17 (41.2%) patients. No serious adverse events were adjudicated as related to the explant procedures. There was a single observation of incision site haemorrhage, that was resolved with wound care. Additional details on lead removal will be included at the time of presentation. Conclusions The EV ICD lead was successfully removed 14-752 days post implant. Nine patients were re-implanted with either extravascular or transvenous systems. Longer term extraction data collection is ongoing through the EV ICD Pivotal study and through the EV ICD post-approval study and will continue to provide additional insights.Lead removed 24 months post-implant.
Efficacy and Safety of an Extravascular Implantable Cardioverter–Defibrillator