Back to Authors

Clementy, Nicolas

Mayo Clinic

Centre Hospitalier Universitaire de Tours

Citations 2

Leadless pacemakers at 5-year follow-up: the Micra transcatheter pacing system post-approval registry
Garweg, Christophe , Clementy, Nicolas, Al-Samadi, Faisal, Iacopino, Saverio , Roberts, Paul R. , Johansen, Jens Brock , Vinolas-Prat, X., Cha, Yong‐Mei , Grubman, Eric , Bordachar, Pierre , Fagan, Dedra H. , Piccini, Jonathan P. , El-Chami, Mikhael F , Garweg, Christophe , Johansen, Jens Brock , Cha, Yong-Mei , Stromberg, Kurt , El‐Chami, Mikhael F. , Clémenty, Nicolas , Martínez‐Sande, José Luis , Tondo, Claudio , Stromberg, Kurt

European Heart Journal | February 9, 2024 | Volume: 45 | Issue: 14 | Pages: 1241-1251

10.1093/eurheartj/ehae101 Get It

Abstract Background and Aims Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. Methods All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine–Gray competing risk models. Results 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6–64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%–5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36–.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%–6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). Conclusions Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.