Iacopino, Saverio

https://orcid.org/0000-0002-2131-1110

Mayo Clinic

University of Milan

Citations 2

Leadless pacemakers at 5-year follow-up: the Micra transcatheter pacing system post-approval registry
Garweg, Christophe , Clementy, Nicolas, Al-Samadi, Faisal, Iacopino, Saverio , Roberts, Paul R. , Johansen, Jens Brock , Vinolas-Prat, X., Cha, Yong‐Mei , Grubman, Eric , Bordachar, Pierre , Fagan, Dedra H. , Piccini, Jonathan P. , El-Chami, Mikhael F , Garweg, Christophe , Johansen, Jens Brock , Cha, Yong-Mei , Stromberg, Kurt , El‐Chami, Mikhael F. , Clémenty, Nicolas , Martínez‐Sande, José Luis , Tondo, Claudio , Stromberg, Kurt

European Heart Journal | February 9, 2024 | Volume: 45 | Issue: 14 | Pages: 1241-1251

10.1093/eurheartj/ehae101 Get It

Abstract Background and Aims Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. Methods All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine–Gray competing risk models. Results 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6–64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%–5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36–.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%–6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). Conclusions Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.
Cryoballoon ablation vs. antiarrhythmic drugs: first-line therapy for patients with paroxysmal atrial fibrillation
Kuniss, Malte , Pavlović, Nikola , Hermida, J S, Healey, Stewart, Arena, Giuseppe , Badenco, Nicolas , Meyer, Christian , Chen, Jian , Iacopino, Saverio , Anselme, Frédéric , Packer, Douglas L. , Pitschner, Heinz-Friedrich, Asmundis, Carlo de , Willems, Stephan , Piazza, Fabio Di , Becker, Daniel , Chierchia, Gian‐Battista , Investigators, for the Cryo-FIRST, Meyer, Christian , Anselme, Frédéric , deAsmundis, Carlo , Velagić, Vedran , Investigators, for the Cryo-FIRST

EP Europace | January 25, 2021 | Volume: 23 | Issue: 7 | Pages: 1033-1041

10.1093/europace/euab029 Get It

AbstractAimsTreatment guidelines for patients with atrial fibrillation (AF) suggest that patients should be managed with an antiarrhythmic drug (AAD) before undergoing catheter ablation (CA). This study evaluated whether pulmonary vein isolation employing cryoballoon CA is superior to AAD therapy for the prevention of atrial arrhythmia (AA) recurrence in rhythm control naive patients with paroxysmal AF (PAF).Methods and resultsA total of 218 treatment naive patients with symptomatic PAF were randomized (1 : 1) to cryoballoon CA (Arctic Front Advance, Medtronic) or AAD (Class I or III) and followed for 12 months. The primary endpoint was ≥1 episode of recurrent AA (AF, atrial flutter, or atrial tachycardia) >30 s after a prespecified 90-day blanking period. Secondary endpoints included the rate of serious adverse events (SAEs) and recurrence of symptomatic palpitations (evaluated via patient diaries). Freedom from AA was achieved in 82.2% of subjects in the cryoballoon arm and 67.6% of subjects in the AAD arm (HR = 0.48, P = 0.01). There were no group differences in the time-to-first (HR = 0.76, P = 0.28) or overall incidence [incidence rate ratio (IRR)=0.79, P = 0.28] of SAEs. The incidence rate of symptomatic palpitations was lower in the cryoballoon (7.61 days/year) compared with the AAD arm (18.96 days/year; IRR = 0.40, P < 0.001).ConclusionsCryoballoon CA was superior to AAD therapy, significantly reducing AA recurrence in treatment naive patients with PAF. Additionally, cryoballoon CA was associated with lower symptom recurrence and a similar rate of SAEs compared with AAD therapy.