University Hospital Southampton NHS Foundation Trust
Citations 4
One-Year Outcomes of the MODULAR ATP Trial: A Novel Leadless Pacemaker in Wireless Communication With a Subcutaneous Implantable Cardioverter Defibrillator
BACKGROUND: MODULAR antitachycardia pacing (ATP), a multicenter, international trial, assesses a modular cardiac rhythm management system: a subcutaneous implantable cardioverter defibrillator in wireless communication with a leadless pacemaker (LP) capable of pace-terminating ventricular tachycardia. METHODS: Enrolees had one or more clinical risk factors for ventricular tachycardia and did not require chronic pacing. Complications included prespecified major LP system- and procedure-related complications, and any complication related to the LP, subcutaneous implantable cardioverter defibrillator, implantation, or study protocol. Survival analysis was performed to identify complication-free rates, therapy delivery, and all-cause mortality. RESULTS: The 297 patients enrolled had an ejection fraction of 35±13%, 43% secondary prevention indications, and 59% with prior ventricular arrhythmias. Of 286 patients undergoing LP implantation (100% success), 251 patients completed 12-month follow-up. Mortality rate was 6%, with none related to the implant procedure. Median follow-up duration was 23.4 months (interquartile range, 17.9–28.1). The LP major complication-free rate was 97.2%, exceeding the performance goal. The overall LP+ subcutaneous implantable cardioverter defibrillator system-related complication-free rate was 88.5%. Appropriate tachyarrhythmia-therapy (ATP+shock) rates were 14.4%, and appropriate shock rates were 8.5%. Inappropriate total tachyarrhythmia therapy was 9.5% of which 8.5% were shocks. ATP was 67.3% successful in terminating ventricular arrhythmia episodes and accelerated ventricular arrhythmias in 10.1% of episodes. Overall therapy burden (ATP+shock) was 96/100 patient-years, of which 44/100 patient-years was for shock delivery. CONCLUSIONS: One-year outcomes of the first modular pacing-defibrillator system reveal low system and LP complication rates and good ATP efficacy rates, suggesting that the modular cardiac rhythm management is a viable alternative to single-chamber implantable cardioverter defibrillators using low-energy pacing capability without the need for transvenous leads. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/ ; Unique identifier: NCT04798768.
A Modular Communicative Leadless Pacing–Defibrillator System
Abstract Background and Aims Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. Methods All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine–Gray competing risk models. Results 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6–64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%–5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36–.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%–6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). Conclusions Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.
Incidence and outcomes of systemic infections in patients with leadless pacemakers: Data from the Micra IDE study
AbstractBackgroundThe Micra clinical trials have enrolled more than 2500 patients without any reported device‐related infections that required removal during follow‐up. Leadless pacemakers might be more resistant to bacterial seeding due to smaller surface area and a greater tendency for encapsulation.ObjectiveTo analyze the incidence and outcomes of serious infectious events (SIEs: bacteremia or endocarditis) that developed during follow‐up in patients with history of Micra leadless pacemaker implantation.MethodsSIE and outcomes were characterized based upon adverse event reports. Among 720 patients implanted with Micra in the investigational device exemption trial, we identified 16 patients who had documented 21 SIEs during follow‐up.ResultsAmong patients with SIEs, mean age was 71.9 ± 11.7 years. SIEs occurred at a mean 4.8 ± 4.5 months after implant and patients were followed for 13.1 ± 9.1 months after documentation of SIE. All events were adjudicated as unrelated to the Micra device or procedure. Bacteremia was documented to be related to a gram‐positive organism in 13 events (seven Staphylococcus, three Streptococcus, two Enterococcus, and one uncharacterized gram‐positive bacteria), and gram‐negative organisms in three events. In five events, the type of organism was not characterized (two patients with endocarditis). No persistent cases of bacteremia after antibiotic cessation were seen over the duration of follow‐upConclusionIn this small series of Micra patients who developed SIEs postimplant, the occurrence of bacteremia and/or endocarditis did not appear to lead to persistent bacteremia off antibiotics; most events resolved with antibiotic treatment.