Back to Authors

Miller, Marc A.

https://orcid.org/0000-0001-7512-4727

Mayo Clinic

Icahn School of Medicine at Mount Sinai

Citations 8

Characteristics of Patients With the Arrhythmogenic Mitral Valve Prolapse Syndrome and Sudden Cardiac Arrest and Sustained Ventricular Arrhythmias
Chakrabarti, Apurba , Giudicessi, John R. , Delling, Francesca N. , Dixit, Shalini , Lee, Yoo Jin , Muser, Daniele , Magnani, Silvia , Wijngaarden, Aniek L. van , Miller, Marc A. , Gandhi, Jonathan, Font, Jonaz , Martins, Raphaël P. , McCaffrey, James A. , Chapagain, Himal , Mathew, Don , Kancharla, Krishna , Syed, Faisal F. , Abid, Ahad, Cerbin, Lukasz , Garg, Lohit , Natale, Andrea , Enríquez, Andrés , Bogun, Frank , Ackerman, Michael J. , Liang, Jackson J. , Ezzeddine, Fatima , Delling, Francesca N , Lee, Yoo Jin , Muser, Daniele , Magnani, Silvia , van Wijngaarden, Aniek , Marsan, Nina Ajmone , Trivieri, Maria G , Font, Jonaz , Martins, Raphael , McCaffrey, James A , Santangeli, Pasquale , Marchlinski, Francis E , Chapagain, Himal , Mathew, Don , Kancharla, Krishna , Syed, Faisal F , Abid, Ahad , Tzou, Wendy , Della Rocca, Domenico G , Natale, Andrea , Mohanty, Sanghamitra , Sheldon, Seth H. , Kuo, Ling , Haugaa, Kristina , Aabel, Eivind W , Enriquez, Andres , Maeda, Shingo , Deshmukh, Amrish , Ackerman, Michael J , Liang, Jackson , Ezzeddine, Fatima M. , Marsan, Nina Ajmone , Santangeli, Pasquale , Marchlinski, Francis E. , Tzou, Wendy S. , Rocca, Domenico G. Della , Haugaa, Kristina H. , Aabel, Eivind W. , Deshmukh, Amrish , Ghannam, Michael

Circulation: Arrhythmia and Electrophysiology | February 20, 2025 | Volume: 18 | Issue: 3 | Pages: No page available

10.1161/circep.124.013099 Get It

BACKGROUND: Patients with arrhythmogenic mitral valve prolapse syndrome are at increased risk for life-threatening ventricular arrhythmias, but studies have been limited by small sample sizes. We sought to assemble an international arrhythmogenic mitral valve prolapse syndrome registry to delineate the clinical, imaging, and treatment characteristics of patients with arrhythmogenic mitral valve prolapse syndrome who survived sudden cardiac arrest (SCA) or had sustained ventricular tachycardia (VT) or ventricular fibrillation. METHODS: In this descriptive registry, we characterized patients with arrhythmogenic mitral valve prolapse syndrome who survived SCA, sustained VT, or ventricular fibrillation. Deidentified data were abstracted locally and combined centrally. RESULTS: We included 148 patients who had SCA or VT/ventricular fibrillation. Patients had a mean age of 43.7±15.4 years; 68% were women, 73% had bileaflet prolapse, 65% had mitral annular disjunction, 67% had nonsustained VT, and 59% had inferolateral T-wave inversions. Syncope (n=54, 48%) and anterolateral T-wave inversion (n=26, 22%) were relatively common. Catheter ablation was performed in 50 (35%) patients for premature ventricular complexes and in 18 (17.7%) patients for VT. Sites of origin for arrhythmias were commonly in the papillary muscles, fascicles, mitral annulus, and inferior/inferolateral left ventricle. CONCLUSIONS: In this international descriptive registry of patients with arrhythmogenic mitral valve prolapse syndrome and SCA, patients were young, women, and had bileaflet mitral valve prolapse, mitral annular disjunction, inferolateral T-wave inversions, and nonsustained VT. A history of syncope and anterolateral T-wave inversions was relatively common in patients who survived SCA or sustained VT/ventricular fibrillation.
Process mapping strategies to prevent subcutaneous implantable cardioverter‐defibrillator infections
Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , McClernon, Timothy R., Knight, Bradley P. , El-Chami, Mikhael F , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , Weiss, Raul , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Hansen, Linda K. , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | June 4, 2022 | Volume: 33 | Issue: 7 | Pages: 1628-1635

10.1111/jce.15566 Get It

AbstractBackgroundInfection remains a major complication of cardiac implantable electronic devices and can lead to significant morbidity and mortality. Implantable devices that avoid transvenous leads, such as the subcutaneous implantable cardioverter‐defibrillator (S‐ICD), can reduce the risk of serious infection‐related complications, such as bloodstream infection and infective endocarditis. While the 2017 AHA/ACC/HRS guidelines include recommendations for S‐ICD use for patients at high risk of infection, currently, there are no clinical trial data that address best practices for the prevention of S‐ICD infections. Therefore, an expert panel was convened to develop a consensus on these topics.MethodsAn expert process mapping methodology was used to achieve consensus on the appropriate steps to minimize or prevent S‐ICD infections. Two face‐to‐face meetings of high‐volume S‐ICD implanters and an infectious diseases specialist, with expertise in cardiovascular implantable electronic device infections, were conducted to develop consensus on useful strategies pre‐, peri‐, and postimplant to reduce S‐ICD infection risk.ResultsExpert panel consensus on recommended steps for patient preparation, S‐ICD implantation, and postoperative management was developed to provide guidance in individual patient management.ConclusionAchieving expert panel consensus by process mapping methodology for S‐ICD infection prevention was attainable, and the results should be helpful to clinicians in adopting interventions to minimize risks of S‐ICD infection.
Abstract 12087: Device-Related Infection Associated With Increased Mortality Risk in de novo Transvenous Implantable Cardioverter-Defibrillator Medicare Patients
Liu, Yiyan , Weiss, Raul, Mark, George E., Lambiase, Pier D. , Miller, Marc A. , Jacobsen, Caroline, Lambiase, Pier D , El‐Chami, Mikhael F. , Griffiths, Robert, Knight, Bradley P. , Biffi, Mauro , Probst, Vincent , Jacobsen, Caroline M., Baddour, Larry M.

Circulation | April 28, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.12087 Get It

Introduction: Device-related infection is estimated to occur in 1.9% of the Medicare patients with de novo transvenous (TV) implantable cardioverter-defibrillators (ICD) within 2 years post-implant. TV-ICD infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to expand on limited published data and assess mortality risk associated with TV-ICD infection in a large Medicare population with de novo TV-ICD implants. Methods: A survival analysis was conducted using 100% fee-for-service Medicare facility-level claims data to identify patients who underwent de novo TV-ICD implantation between 7/2016 and 1/2018. TV-ICD infection within 2 years of implantation was identified using ICD-10 and CPT codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time-dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias. Results: Among 26,742 Medicare patients with de novo TV-ICD, 518 (1.9%) had a device-related infection. The overall number of decedents was 4,721 (17.7%) over 2 years, with 4,555 (17%) in the non-infection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV-ICD infection was associated with an increase of 2.4 [95% CI: 2.08-2.85] times in the mortality hazard ratio (see attached Figure). Most of the baseline patient risk factors were also associated with higher risk of mortality in the Cox model. Conclusion: The rate of de novo TV-ICD infection and associated mortality in a large, real-world Medicare population is noteworthy. The positive association between device-related infection and risk of mortality further highlights the need to reduce infections.
Device‐related infection associated with increased mortality risk in de novo transvenous implantable cardioverter‐defibrillator medicare patients
Liu, Yiyan , Griffiths, Robert I. , Knight, Bradley P. , Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , Jacobsen, Caroline M., El-Chami, Mikhael F , Weiss, Raul , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | January 23, 2022 | Volume: 33 | Issue: 4 | Pages: 725-730

10.1111/jce.15385 Get It

AbstractIntroductionTransvenous implantable cardioverter‐defibrillators (TV‐ICD) infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to assess mortality risk associated with TV‐ICD infection in a large Medicare population with de novo TV‐ICD implants.MethodsA survival analysis was conducted using 100% fee‐for‐service Medicare facility‐level claims data to identify patients who underwent de novo TV‐ICD implantation between 7/2016 and 1/2018. TV‐ICD infection within 2 years of implantation was identified using International Classification of Disease, 10th Edition and current procedural terminology codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time‐dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias.ResultsAmong 26,742 Medicare patients with de novo TV‐ICD, 518 (1.9%) had a device‐related infection. The overall number of decedents was 4721 (17.7%) over 2 years, with 4555 (17%) in the noninfection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV‐ICD infection was associated with an increase of 2.4 (95% CI: 2.08–2.85) times in the mortality hazard ratio.ConclusionThe rate of TV‐ICD infection and associated mortality in a large, real‐world Medicare population is noteworthy. The positive association between device‐related infection and risk of mortality further highlights the need to reduce infections
Process Mapping Strategies to Prevent Subcutaneous Implantable Cardioverter-Defibrillator Infection
Weiss, Raul , Mark, G. J., Miller, Marc A. , McClernon, Timothy R., Weiss, Raul , Mark, George, El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Lambiase, Pier D. , Hansen, Linda, Knight, Bradley P. , Baddour, Larry M.

No container title available | January 2, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.164118494.47265902/v1 Get It

Background: Infection remains a major complication of cardiac implantable electronic devices (CIEDs) and can lead to significant morbidity and mortality. Extrathoracic devices that avoid epicardial or transvenous leads, such as the subcutaneous implantable cardioverter-defibrillator (S-ICD), can reduce the risk of serious infection-related complications, such as bloodstream infection and infective endocarditis. While the 2017 AHA/ACC/HRS guidelines include recommendations for S-ICD use for patients at high risk of infection, currently, there are no clinical trial data that address best practices for the prevention of S-ICD infections. Therefore, an expert panel was convened to develop consensus on these topics. Methods: An expert process mapping methodology was used to achieve consensus on the appropriate steps to minimize or prevent S-ICD infections. Two face-to-face meetings of high-volume S-ICD implanters and an infectious diseases specialist, with expertise on cardiovascular implantable electronic device infections, were conducted to develop consensus on useful strategies pre-, peri-, and post-implant to reduce S-ICD infection risk. Results: Expert panel consensus of recommended steps for patient preparation, S-ICD implantation, and post-operative management were developed to provide guidance in individual patient management. Conclusion: Achieving expert panel consensus by process mapping methodology for S-ICD infection prevention was attainable, and the results should be helpful to clinicians in adopting interventions to minimize risks of S-ICD infection.
Abstract 15562: Incidence and Risk Factors of Device-related Infection in De Novo Transvenous Implantable Cardiac Defibrillator Medicare Patients
Jacobsen, Caroline M., Wold, Nicholas , Amorosi, Stacey L., Stivland, Timothy M. , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , Lambiase, Pier D , El‐Chami, Mikhael F. , Griffiths, Robert I, Hansen, Linda K. , Knight, Bradley P. , Weiss, Raul , Biffi, Mauro , Probst, Vincent , Baddour, Larry M.

Circulation | May 10, 2021 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.15562 Get It

Introduction: Practice guidelines recommend use of subcutaneous implantable cardioverter-defibrillators (ICD) in patients (pts) at risk of sudden cardiac death and high risk for infection. This has prompted a need to better identify pts at high risk of infection to assist in de novo device selection. The objective of this study is to estimate infection incidence in de novo transvenous (TV) ICD implants and assess risk factors associated with infection in a large Medicare population. Methods: A retrospective cohort study was conducted using 100% Medicare administrative and claims data to identify pts who underwent de novo TV-ICD implantation between 7/2016 and 1/2018. Device-related infection within 2 years of implantation was identified using ICD-10 diagnosis and procedure codes. Baseline pt factors associated with infection were identified by univariable logistic regression analysis of all variables of interest, including factors in Charlson and Elixhauser comorbidity indices, followed by stepwise selection criteria with a p≤0.25 for inclusion in a multivariable model and a backwards, stepwise elimination process with p≤0.1 to remain in the model. A time-to-event analysis was also conducted. Results: Among 26,742 pts with de novo TV-ICD, 519 (1.9%) had a device-related infection over 2 years. The mean pt age with and without infection was 68 and 71 years, respectively. While more than half (54%) of infections occurred within 90 days post implant, infections continued to be diagnosed with 16% of infections occurring between years 1 and 2. Multivariable analysis revealed several significant predictors of infection (Figure) including age <70 years, end stage renal disease with chronic dialysis and diabetes with complications. Conclusion: The rate of de novo TV-ICD infection in a large real-world Medicare population is clinically significant. The factors associated with increased infection risk identified here can be used to help determine device selection.
Diagnosis and management of subcutaneous implantable cardioverter‐defibrillator infections based on process mapping
Baddour, Larry M. , Weiss, Raul , Mark, George E., Biffi, Mauro , Probst, Vincent , Lambiase, Pier D. , Miller, Marc A. , McClernon, Timothy R., Hansen, Linda K. , Knight, Bradley P. , El-Chami, Mikhael F , Biffi, Mauro , Probst, Vincent , Lambiase, Pier D , Hansen, Linda K , Knight, Bradley P , Baddour, Larry , Weiss, Raul , El‐Chami, Mikhael F.

Pacing and Clinical Electrophysiology | April 8, 2020 | Volume: 43 | Issue: 9 | Pages: 958-965

10.1111/pace.13902 Get It

AbstractBackgroundInfection is a well‐recognized complication of cardiovascular implantable electronic device (CIED) implantation, including the more recently available subcutaneous implantable cardioverter‐defibrillator (S‐ICD). Although the AHA/ACC/HRS guidelines include recommendations for S‐ICD use, currently there are no clinical trial data that address the diagnosis and management of S‐ICD infections. Therefore, an expert panel was convened to develop consensus on these topics.MethodsA process mapping methodology was used to achieve a primary goal – the development of consensus on the diagnosis and management of S‐ICD infections. Two face‐to‐face meetings of panel experts were conducted to recommend useful information to clinicians in individual patient management of S‐ICD infections.ResultsPanel consensus of a stepwise approach in the diagnosis and management was developed to provide guidance in individual patient management.ConclusionAchieving expert panel consensus by process mapping methodology in S‐ICD infection diagnosis and management was attainable, and the results should be helpful in individual patient management.