Doshi, Rahul N.

https://orcid.org/0000-0001-5555-7672

Mayo Clinic

HonorHealth

Citations 4

One-Year Outcomes of the MODULAR ATP Trial: A Novel Leadless Pacemaker in Wireless Communication With a Subcutaneous Implantable Cardioverter Defibrillator
Lloyd, Michael S. , Roberts, Paul R. , Doshi, Rahul N. , Wright, David J. , Boersma, Lucas V.A. , Friedman, Paul A. , Neužil, Petr , Blomström‐Lundqvist, Carina , Bongiorni, M. G. , Burke, Martin C. , Gras, Daniel , Kutalek, Steven , Marijon, Éloi , Amin, Anish K. , Aasbo, Johan D. , West, Julie, Matznick, Elizabeth , Speakman, Benjamin, Bachman, Tara N. , Reddy, Vivek Y , Roberts, Paul , Doshi, Rahul N , Wright, David L , Boersma, Lucas , Friedman, Paul A , Neuzil, Petr , Blomström-Lundqvist, Carina , Bongiorni, Maria Grazia , Burke, Martin C , Gras, Daniel , Kutalek, Steven P , Marijon, Eloi , Tolosana, Jose María , Amin, Anish K , Epstein, Laurence M , Aasbo, Johan D , Callahan, Thomas D , Brisben, Amy J , Matznick, Elizabeth , Bachman, Tara N , Mont, Lluís , Knops, Reinoud Elwin , Reddy, Vivek Y. , Epstein, Laurence M.

Circulation: Arrhythmia and Electrophysiology | November 13, 2025 | Volume: 19 | Issue: 1 | Pages: No page available

10.1161/circep.125.014395 Get It

BACKGROUND: MODULAR antitachycardia pacing (ATP), a multicenter, international trial, assesses a modular cardiac rhythm management system: a subcutaneous implantable cardioverter defibrillator in wireless communication with a leadless pacemaker (LP) capable of pace-terminating ventricular tachycardia. METHODS: Enrolees had one or more clinical risk factors for ventricular tachycardia and did not require chronic pacing. Complications included prespecified major LP system- and procedure-related complications, and any complication related to the LP, subcutaneous implantable cardioverter defibrillator, implantation, or study protocol. Survival analysis was performed to identify complication-free rates, therapy delivery, and all-cause mortality. RESULTS: The 297 patients enrolled had an ejection fraction of 35±13%, 43% secondary prevention indications, and 59% with prior ventricular arrhythmias. Of 286 patients undergoing LP implantation (100% success), 251 patients completed 12-month follow-up. Mortality rate was 6%, with none related to the implant procedure. Median follow-up duration was 23.4 months (interquartile range, 17.9–28.1). The LP major complication-free rate was 97.2%, exceeding the performance goal. The overall LP+ subcutaneous implantable cardioverter defibrillator system-related complication-free rate was 88.5%. Appropriate tachyarrhythmia-therapy (ATP+shock) rates were 14.4%, and appropriate shock rates were 8.5%. Inappropriate total tachyarrhythmia therapy was 9.5% of which 8.5% were shocks. ATP was 67.3% successful in terminating ventricular arrhythmia episodes and accelerated ventricular arrhythmias in 10.1% of episodes. Overall therapy burden (ATP+shock) was 96/100 patient-years, of which 44/100 patient-years was for shock delivery. CONCLUSIONS: One-year outcomes of the first modular pacing-defibrillator system reveal low system and LP complication rates and good ATP efficacy rates, suggesting that the modular cardiac rhythm management is a viable alternative to single-chamber implantable cardioverter defibrillators using low-energy pacing capability without the need for transvenous leads. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/ ; Unique identifier: NCT04798768.
A wearable cardioverter defibrillator with a low false alarm rate
Poole, Jeanne E. , Gleva, Marye J. , Birgersdotter‐Green, Ulrika , Branch, Kelley R. , Salam, Tariq , Crawford, Thomas , Willcox, Mark E. , Sridhar, Arun Mahankali, Mikdadi, Ghiath, Beinart, Sean C., Cha, Yong‐Mei , Russo, Andrea M. , Rowbotham, Ron, Sullivan, Joseph, Gustavson, Laura , Kivilaid, Kaisa, Salam, Tariq , Cha, Yong-Mei , Doshi, Rahul N.

Journal of Cardiovascular Electrophysiology | February 17, 2022 | Volume: 33 | Issue: 5 | Pages: 831-842

10.1111/jce.15417 Get It

AbstractIntroductionA wearable cardioverter defibrillator (WCD) is indicated in appropriate patients to reduce the risk for sudden cardiac death. Challenges for patients wearing a WCD have been frequent false shock alarms primarily due to electrocardiogram noise and wear discomfort. The objective of this study was to test a contemporary WCD designed for reduced false shock alarms and improved comfort.MethodsOne hundred and thirty patients with left ventricular ejection fraction ≤40% and an active implantable cardioverter defibrillator (ICD) were fitted with the ASSURE WCD (Kestra Medical Technologies) and followed for 30 days. WCD detection was enabled and shock alarm markers recorded, but shocks and shock alarms were disabled. All WCD episodes and ICD ventricular tachycardia/ventricular fibrillation (VT/VF) episodes were adjudicated. The primary endpoint was the false‐positive shock alarm rate with a performance goal of 1 every 3.4 days (0.29 per patient‐day).ResultsOf 163 WCD episodes, 4 were VT/VF and 159 non‐VT/VF (121 rhythms with noise, 32 uncertain with noise, 6 atrial flutter without noise). Only three false‐positive shock alarm markers were recorded; one false‐positive shock alarm every 1333 patient‐days (0.00075 per patient‐day, 95% confidence interval: 0.00015–0.00361; p < .001). No ICD recorded VT/VF episodes meeting WCD detection criteria (≥170 bpm for ≥20 s) were missed by the WCD during 3501 patient‐days of use. Median wear was 31.0 days (interquartile range [IQR] 2.0) and median daily use 23.0 h (IQR 1.7). Adverse events were mostly mild: skin irritation (19.4%) and musculoskeletal discomfort (8.5%).ConclusionThe ASSURE WCD demonstrated a low false‐positive shock alarm rate, low patient‐reported discomfort, and no serious adverse events.
P4415Long obstructive sleep apneas as a biomarker of atrial fibrillation
Allam, Sahitya , Valladares, Edwin M. , Grbach, Vincent X., Basrawala, Hussain, Patel, Krishan , Konecna, Eliska, Khoo, Michael C. K. , Konečný, Tomáš , Reddy, Pavan K. V. , Hammond, Terese , Konecny, V, Borok, Zea , Doshi, Rahul N. , Somers, Virend K.

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz745.0818 Get It

Abstract Background Even though obstructive sleep apnea (OSA) is strongly associated with atrial fibrillation (AF), the use of traditional OSA scoring by apnea hypopnea index (AHI) did not result in improved arrhythmia outcomes in recent randomized trials. Longer OSA episodes lead to stronger pro-arrhythmic changes, and whether very long OSA episodes are more prevalent in AF patients remains unknown. Purpose We hypothesized that AF patients with mild-moderate OSA manifest greater percentage of long (>20s), very long (>30s), and extremely long (>40s) OSA episodes, compared to control OSA patients matched to AHI, age and sex. Methods From patients studied with diagnostic polysomnography in our laboratory between 2016 and 2018, we selected 22 patients with mild-moderate untreated OSA of which 11 patients had history of paroxysmal AF and 11 patients did not have any cardiac history. The length, oxygen desaturation, and relationship to neighboring events was manually re-measured in all recorded apnea and hypopnea events. Results In the 22 included patients (age 62.5±9.1 years, AHI 12.8±6.1, 40% female) we recorded 1021 apneas: 508 in the AF group and 513 in the control group. AF patients had longer apneas compared to the patients without AF history (mean length 28.7±11.7s vs. 23.3±9.9s; p<0.0001). The proportion of apneas that were long (>20s), very long (>30s), and extremely long (>40s) was greater in the AF group as compared to the control (p=0.0039, p=0.0215, p=0.0104, respectively; see figure). The acute oxygen saturation drops (>2%) during apneas were comparable between the AF group and control groups (p=0.13), but the long (>20s) apneas were prone to greater oxygen desaturations. Length of Apneas Conclusions While traditional scoring of OSA focuses on episodes lasting >10s, our data newly show that longer durations of OSA events are particularly prevalent in AF patients. These results, combined with recent mechanistic studies showing that longer apneas exert greater pro-arrhythmic effect on atrial conduction, suggest that novel scoring of OSA placing more weight on longer apneas should be explored, especially when screening and titrating OSA therapy in patients at risk of AF.