Abstract Background and Aims Stroke and systemic embolism are recognized but poorly characterized complications of atrial fibrillation (AF) and left atrial flutter (AFL) catheter ablation. Their incidence, outcomes, and procedural associations remain insufficiently defined. Methods Retrospective global registry was initiated by the European Heart Rhythm Association Scientific Committee. A secure database captured data from ablation centres worldwide on general AF and left AFL ablation activity, as well as detailed information on patients with symptomatic embolic events between 2017 and 2024. Results Overall, 204 centres reported 335 743 ablation procedures and 550 embolic events (incidence 0.16%). Centre-level rate ranged from 0% to 3.1%. Most events were cerebral (94%), followed by peripheral (5%), and combined (1%). Coronary air embolism accounted for 62% of all peripheral events. Intraprocedural events occurred in 93 patients (17%), within 72 h in 357 (78%) and beyond 72 h in 100 (22%); 128 cases (23%) were diagnosed after hospital discharge. Nonparoxysmal AF (0.23% vs 0.15%; P < .001), centre experience, and ablation energy source (radiofrequency, 0.16%; cryoballoon, 0.16%; pulsed field ablation, 0.25%; laserballoon, 0.88%; P < .001) were associated with embolic risk. Median NIHSS score after stroke was 4 (interquartile range, 2–9). Three-month follow-up was available for 518 patients with embolism (95%): 181 (35%) had sequelae and 16 (3%) died. Conclusions Symptomatic embolic events are infrequent but associated with significant morbidity and mortality. Most events occur early, though a substantial proportion arise later. Higher event rates were observed with laser and possibly with pulsed field ablation. A greater centre experience was associated with a lower embolism incidence.
One-Year Outcomes of the MODULAR ATP Trial: A Novel Leadless Pacemaker in Wireless Communication With a Subcutaneous Implantable Cardioverter Defibrillator
BACKGROUND: MODULAR antitachycardia pacing (ATP), a multicenter, international trial, assesses a modular cardiac rhythm management system: a subcutaneous implantable cardioverter defibrillator in wireless communication with a leadless pacemaker (LP) capable of pace-terminating ventricular tachycardia. METHODS: Enrolees had one or more clinical risk factors for ventricular tachycardia and did not require chronic pacing. Complications included prespecified major LP system- and procedure-related complications, and any complication related to the LP, subcutaneous implantable cardioverter defibrillator, implantation, or study protocol. Survival analysis was performed to identify complication-free rates, therapy delivery, and all-cause mortality. RESULTS: The 297 patients enrolled had an ejection fraction of 35±13%, 43% secondary prevention indications, and 59% with prior ventricular arrhythmias. Of 286 patients undergoing LP implantation (100% success), 251 patients completed 12-month follow-up. Mortality rate was 6%, with none related to the implant procedure. Median follow-up duration was 23.4 months (interquartile range, 17.9–28.1). The LP major complication-free rate was 97.2%, exceeding the performance goal. The overall LP+ subcutaneous implantable cardioverter defibrillator system-related complication-free rate was 88.5%. Appropriate tachyarrhythmia-therapy (ATP+shock) rates were 14.4%, and appropriate shock rates were 8.5%. Inappropriate total tachyarrhythmia therapy was 9.5% of which 8.5% were shocks. ATP was 67.3% successful in terminating ventricular arrhythmia episodes and accelerated ventricular arrhythmias in 10.1% of episodes. Overall therapy burden (ATP+shock) was 96/100 patient-years, of which 44/100 patient-years was for shock delivery. CONCLUSIONS: One-year outcomes of the first modular pacing-defibrillator system reveal low system and LP complication rates and good ATP efficacy rates, suggesting that the modular cardiac rhythm management is a viable alternative to single-chamber implantable cardioverter defibrillators using low-energy pacing capability without the need for transvenous leads. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/ ; Unique identifier: NCT04798768.
Association between basic life support and survival in sports-related sudden cardiac arrest: a meta-analysis
Abstract Aims To evaluate the association of basic life support with survival after sports-related sudden cardiac arrest (SR-SCA). Methods and results In this systematic review and meta-analysis, a search of several databases from each database inception to 31 July 2021 without language restrictions was conducted. Studies were considered eligible if they evaluated one of three scenarios in patients with SR-SCA: (i) bystander presence, (ii) bystander cardiopulmonary resuscitation (CPR), or (iii) bystander automated external defibrillator (AED) use and provided information on survival. Risk of bias was evaluated using Risk of Bias in Non-randomized Studies of Interventions. The primary outcome was survival at the longest follow up. The meta-analysis was conducted using the random-effects model. The Grading of Recommendations Assessment, Development, and Evaluations (GRADE) approach was used to rate certainty in the evidence. In total, 28 non-randomized studies were included. The meta-analysis showed significant benefit on survival in all three groups: bystander presence [odds ratio (OR) 2.55, 95% confidence interval (CI) 1.48–4.37; I2 = 25%; 9 studies—988 patients], bystander CPR (OR 3.84, 95% CI 2.36–6.25; I2 = 54%; 23 studies—2523 patients), and bystander AED use (OR 5.25, 95% CI 3.58–7.70; I2 = 16%; 19 studies—1227 patients). The GRADE certainty of evidence was judged to be moderate. Conclusion In patients with SR-SCA, bystander presence, bystander CPR, and bystander AED use were significantly associated with survival. These results highlight the importance of witness intervention and encourage countries to develop their first aid training policy and AED installation in sport settings.