Abstract Objectives This study aimed to investigate the procedural characteristics, efficacy, and safety of atrioventricular junction (AVJ) ablation for atrial tachyarrythmia (AT) in patients with congenital heart disease (CHD). Background Although AVJ ablation is an established treatment option for intractable AT in the general population, there is no existing data on this treatment in patients with CHD. Methods Data were analyzed from an observational, retrospective, multicenter cohort, initiated jointly by the Pediatric and Congenital Electrophysiology Society and the International Society of Adult Congenital Heart Disease. Eleven centers contributed baseline, procedural and longitudinal data, including vital status, echocardiographic data, QRS duration, and NYHA class. Outcomes were assessed at early (3 months-1 year), and late follow-up (≥2 years) after AVJ ablation. Results A total of 66 patients (46.7 ± 20.2 years) underwent 71 AVJ ablations. In total, 58.5% had moderate or complex CHD, including 17.1% patients with a systemic RV or single ventricular circulation. The cumulative AVJ ablation success rate was 98.5%. An abnormal location of the atrioventricular conduction pathway was successfully targeted in 20.0% of the patients, which was significantly more common in patients with complex CHD compared to moderate or mild CHD (44.4%, 15.8%, and 3.6%, respectively; both P<0.05). Thirty-six patients (54.5%) underwent primary pacemaker implantation as part of the ‘pace and ablate’ strategy; final pacing modes were VVI pacing in 60.9%, and CRT/CSP in 39.1%. The transplant-free survival rates at 2, 5 and 10 years after AVJ ablation were 91.5%, 84.3%, and 69.0%, respectively. The acute and long-term complication rates were 3.0% and 13.6%, respectively. Conclusions AVJ ablation can be successfully performed in CHD patients with a high acute success rate and low complication rate. Anatomical challenges were common, which underscores the need for careful planning and operator experience. Given the acceptable long-term survival, these findings support the consideration of a ‘pace and ablate’ strategy in CHD patients with intractable AT.
One-Year Outcomes of the MODULAR ATP Trial: A Novel Leadless Pacemaker in Wireless Communication With a Subcutaneous Implantable Cardioverter Defibrillator
BACKGROUND: MODULAR antitachycardia pacing (ATP), a multicenter, international trial, assesses a modular cardiac rhythm management system: a subcutaneous implantable cardioverter defibrillator in wireless communication with a leadless pacemaker (LP) capable of pace-terminating ventricular tachycardia. METHODS: Enrolees had one or more clinical risk factors for ventricular tachycardia and did not require chronic pacing. Complications included prespecified major LP system- and procedure-related complications, and any complication related to the LP, subcutaneous implantable cardioverter defibrillator, implantation, or study protocol. Survival analysis was performed to identify complication-free rates, therapy delivery, and all-cause mortality. RESULTS: The 297 patients enrolled had an ejection fraction of 35±13%, 43% secondary prevention indications, and 59% with prior ventricular arrhythmias. Of 286 patients undergoing LP implantation (100% success), 251 patients completed 12-month follow-up. Mortality rate was 6%, with none related to the implant procedure. Median follow-up duration was 23.4 months (interquartile range, 17.9–28.1). The LP major complication-free rate was 97.2%, exceeding the performance goal. The overall LP+ subcutaneous implantable cardioverter defibrillator system-related complication-free rate was 88.5%. Appropriate tachyarrhythmia-therapy (ATP+shock) rates were 14.4%, and appropriate shock rates were 8.5%. Inappropriate total tachyarrhythmia therapy was 9.5% of which 8.5% were shocks. ATP was 67.3% successful in terminating ventricular arrhythmia episodes and accelerated ventricular arrhythmias in 10.1% of episodes. Overall therapy burden (ATP+shock) was 96/100 patient-years, of which 44/100 patient-years was for shock delivery. CONCLUSIONS: One-year outcomes of the first modular pacing-defibrillator system reveal low system and LP complication rates and good ATP efficacy rates, suggesting that the modular cardiac rhythm management is a viable alternative to single-chamber implantable cardioverter defibrillators using low-energy pacing capability without the need for transvenous leads. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/ ; Unique identifier: NCT04798768.
A Modular Communicative Leadless Pacing–Defibrillator System
Background The objective of this international multicenter study was to investigate both early and late outcomes of cardiac resynchronization therapy (CRT) in patients with a systemic right ventricle (SRV) and to identify predictors for congestive heart failure readmissions and mortality. Methods and Results This retrospective international multicenter study included 13 centers. The study population comprised 80 adult patients with SRV (48.9% women) with a mean age of 45±14 (range, 18–77) years at initiation of CRT. Median follow‐up time was 4.1 (25th–75th percentile, 1.3–8.3) years. Underlying congenital heart disease consisted of congenitally corrected transposition of the great arteries and dextro‐transposition of the great arteries in 63 (78.8%) and 17 (21.3%) patients, respectively. CRT resulted in significant improvement in functional class (before CRT: III, 25th–75th percentile, II–III; after CRT: II, 25th–75th percentile, II–III; P =0.005) and QRS duration (before CRT: 176±27; after CRT: 150±24 milliseconds; P =0.003) in patients with pre‐CRT ventricular pacing who underwent an upgrade to a CRT device (n=49). These improvements persisted during long‐term follow‐up with a marginal but significant increase in SRV function (before CRT; 30%, 25th–75th percentile, 25–35; after CRT: 31%, 25th–75th percentile, 21–38; P =0.049). In contrast, no beneficial change in the above‐mentioned variables was observed in patients who underwent de novo CRT (n=31). A quarter of all patients were readmitted for heart failure during follow‐up, and mortality at latest follow‐up was 21.3%. Conclusions This international experience with CRT in patients with an SRV demonstrated that CRT in selected patients with SRV dysfunction and pacing‐induced dyssynchrony yielded consistent improvement in QRS duration and New York Heart Association functional status, with a marginal increase in SRV function.
Implantation of leadless pacemakers via inferior vena cava filters is feasible and safe: Insights from a multicenter experience
AbstractBackgroundThe leadless Micra transcatheter‐pacing system (Micra‐TPS) is implanted via a femoral approach using a 27‐French introducer sheath. The Micra Transcutaneous Pacing Study excluded patients with inferior vena cava (IVC) filters.ObjectiveTo examine the feasibility and safety of Micra‐TPS implantation through an IVC filter.MethodsThis multicenter retrospective study included patients with an IVC filter who underwent a Micra‐TPS implantation. Data for clinical and IVC filter characteristics, preprocedure imaging, and procedural interventions were collected. The primary outcome was a successful leadless pacemaker (LP) implantation via a femoral approach in the presence of an IVC filter. Periprocedural and delayed clinical complications were also evaluated.ResultsOf the 1528 Micra‐TPS implants attempted, 23 patients (1.5%) had IVC filters. The majority (69.6%) of IVC filters were permanent. Six (26.1%) patients underwent preprocedural imaging to assess for filter patency. One patient's filter was retrieved before LP implantation. The primary outcome was achieved in 21 of 22 patients (95.5%) with an existing IVC filter. An occluded IVC precluded LP implantation in one patient. Difficulty advancing the stiff guidewire or the 27‐Fr sheath was encountered in five patients. These cases required repositioning of the wire (n = 2), gradual sheath upsizing (n = 2), or balloon dilation of the filter (n = 1). Postprocedure fluoroscopy revealed intact filters in all cases. During a median 6‐month follow‐up, there were no clinical complications related to the filter or the Micra‐TPS.ConclusionThis multicenter experience demonstrates the feasibility and safety of Micra‐TPS implantation via an IVC filter without acute procedural or delayed clinical complications.