Implantable cardioverter-defibrillator (ICD) therapy in children and congenital heart disease (CHD) patients is hampered by poor long-term lead survival. Lead extraction is technically difficult and carries substantial morbidity. Manufacturers developed distinct strategies for this issue: thinner lead bodies or a Gore ePTFE coil coating. Both design changes were thought to improve ease of lead removal, but have not been directly compared in children or adults. The purpose of this study was to assess thin and ePTFE-coated ICD lead survival in pediatric and CHD pts. Methods: The Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study began as a Phase IV multicenter open-label prospective study [ NCT00335036 ], facilitated by the Pediatric & Congenital EP Society. Initially designed as a randomized study, it changed to a parallel assignment registry when 1 lead had an advisory due to high incidence of failure, prompting concern about continued clinical equipoise. Pediatric and CHD pts who underwent ICD lead implant from 2005-2010 were eligible. The end date was NCDR ICD Registry v2.0 release (includes pediatric & lead data). 23 centers participated; each site obtained IRB approval. De-identified data was sent to the PI center for verification and statistical analyses. Results: A total of 982 ICD pts (357 VVI, 558 DDD, 67 CRT-D) entered the PLEASE study, incl. 423 pts (43%) with CHD. Mean age at implant = 18.3 ± 9.9 yrs. Thin (< 7Fr) ICD leads accounted for 51%, 23% were ePTFE-coated, 26% neither thin nor coated. There were 113 ICD lead failures (11.5%) at a mean lead-age of 2.2 ± 1.7 yrs, causing shocks in 55 pts. Failure occurred in 21% of thin leads vs 3.5% of ePTFE leads (p<0.01). Extraction was performed on 142 (14.5%) leads overall; 21% of thin leads (incl. extraction of 29 functioning leads due to recall) vs. 4.4% of ePTFE leads (p<0.01). There were 7 major extraction complications (4.9%), but no procedural mortality. Among thin leads, 90/270 (33.3%) of recalled leads failed vs 15/229 (6.6%) non-recalled thin leads. Conclusions: This Phase IV study demonstrates that ICD leads in children and CHD pts have suboptimal performance overall. Thinner leads were much more likely to fail and/or be extracted compared with ePTFE leads, chiefly driven by one lead type.
Cardiac Resynchronization Therapy for Adult Patients With a Failing Systemic Right Ventricle: A Multicenter Study
Background The objective of this international multicenter study was to investigate both early and late outcomes of cardiac resynchronization therapy (CRT) in patients with a systemic right ventricle (SRV) and to identify predictors for congestive heart failure readmissions and mortality. Methods and Results This retrospective international multicenter study included 13 centers. The study population comprised 80 adult patients with SRV (48.9% women) with a mean age of 45±14 (range, 18–77) years at initiation of CRT. Median follow‐up time was 4.1 (25th–75th percentile, 1.3–8.3) years. Underlying congenital heart disease consisted of congenitally corrected transposition of the great arteries and dextro‐transposition of the great arteries in 63 (78.8%) and 17 (21.3%) patients, respectively. CRT resulted in significant improvement in functional class (before CRT: III, 25th–75th percentile, II–III; after CRT: II, 25th–75th percentile, II–III; P =0.005) and QRS duration (before CRT: 176±27; after CRT: 150±24 milliseconds; P =0.003) in patients with pre‐CRT ventricular pacing who underwent an upgrade to a CRT device (n=49). These improvements persisted during long‐term follow‐up with a marginal but significant increase in SRV function (before CRT; 30%, 25th–75th percentile, 25–35; after CRT: 31%, 25th–75th percentile, 21–38; P =0.049). In contrast, no beneficial change in the above‐mentioned variables was observed in patients who underwent de novo CRT (n=31). A quarter of all patients were readmitted for heart failure during follow‐up, and mortality at latest follow‐up was 21.3%. Conclusions This international experience with CRT in patients with an SRV demonstrated that CRT in selected patients with SRV dysfunction and pacing‐induced dyssynchrony yielded consistent improvement in QRS duration and New York Heart Association functional status, with a marginal increase in SRV function.