Citations 7

Vigorous Exercise in Patients With Congenital Long QT Syndrome: Results of the Prospective, Observational, Multinational LIVE-LQTS Study
Lampert, Rachel , Day, Sharlene M. , Ainsworth, Barbara E. , Burg, Matthew M. , Marino, Bradley S. , Salberg, Lisa , Tome, Maite , Abrams, Dominic J. , Aziz, Peter F. , Barth, Cheryl , Behr, Elijah R. , Bell, Cheyanne , Berul, Charles I. , Bos, J. Martijn , Cannom, David S. , Cannon, Bryan C. , Concannon, Maryann, Czosek, Richard J. , Dubin, Anne M. , Dziura, James , Erickson, Christopher C. , Etheridge, Susan P. , Gray, Belinda , Haglund-Turnquist, Carla , Johnsrude, Christopher L. , Lara, Alice, Saarel, Elizabeth V. , Sanatani, Shubhayan , Shah, Maully J. , Simone, Laura, Tomaselli, Gordon F., Ware, James S. , Zaręba, Wojciech , Ackerman, Michael J. , Day, Sharlene , Burg, Matthew , Tome Esteban, Maria Teresa , Bos, Johan M , Cannon, Bryan C , Cerrone, Marina , Czosek, Richard J , Dubin, Anne M , Dziura, James , Erickson, Christopher C , Estes, N.A. Mark , Etheridge, Susan P , Goldenberg, Ilan , Gray, Belinda , Haglund-Turnquist, Carla M , Harmon, Kimberly G , James, Cynthia A , Johnsrude, Christopher , Kannankeril, Prince J , Law, Ian H , Link, Mark S. , Molossi, Silvana M , Olshansky, Brian , Noseworthy, Peter A , Saarel, Elizabeth V , Sanatani, Shubhayan , Shah, Maully , Skinner, Jonathan R , Ware, James S , Webster, Gregory , Zareba, Wojciech , Zipes, Douglas P , Ackerman, Michael J , Behr, Elijah Raphael , Abrams, Dominic J , Bradley, David J. , Cerrone, Marina , Goldenberg, Ilan , Harmon, Kimberly G. , James, Cynthia A. , Kannankeril, Prince J. , Law, Ian H. , Li, Fangyong , Olshansky, Brian , Noseworthy, Peter A. , Skinner, Jonathan R. , Webster, Gregory , Zipes, Douglas P.

Circulation | July 25, 2024 | Volume: 150 | Issue: 7 | Pages: 516-530

10.1161/circulationaha.123.067590 Get It

BACKGROUND: Whether vigorous exercise increases risk of ventricular arrhythmias for individuals diagnosed and treated for congenital long QT syndrome (LQTS) remains unknown. METHODS: The National Institutes of Health–funded LIVE-LQTS study (Lifestyle and Exercise in the Long QT Syndrome) prospectively enrolled individuals 8 to 60 years of age with phenotypic and/or genotypic LQTS from 37 sites in 5 countries from May 2015 to February 2019. Participants (or parents) answered physical activity and clinical events surveys every 6 months for 3 years with follow-up completed in February 2022. Vigorous exercise was defined as ≥6 metabolic equivalents for >60 hours per year. A blinded Clinical Events Committee adjudicated the composite end point of sudden death, sudden cardiac arrest, ventricular arrhythmia treated by an implantable cardioverter defibrillator, and likely arrhythmic syncope. A National Death Index search ascertained vital status for those with incomplete follow-up. A noninferiority hypothesis (boundary of 1.5) between vigorous exercisers and others was tested with multivariable Cox regression analysis. RESULTS: Among the 1413 participants (13% <18 years of age, 35% 18–25 years of age, 67% female, 25% with implantable cardioverter defibrillators, 90% genotype positive, 49% with LQT1, 91% were treated with beta-blockers, left cardiac sympathetic denervation, and/or implantable cardioverter defibrillator), 52% participated in vigorous exercise (55% of these competitively). Thirty-seven individuals experienced the composite end point (including one sudden cardiac arrest and one sudden death in the nonvigorous group, one sudden cardiac arrest in the vigorous group) with overall event rates at 3 years of 2.6% in the vigorous and 2.7% in the nonvigorous exercise groups. The unadjusted hazard ratio for experience of events for the vigorous group compared with the nonvigorous group was 0.97 (90% CI, 0.57–1.67), with an adjusted hazard ratio of 1.17 (90% CI, 0.67–2.04). The upper 95% one-sided confidence level extended beyond the 1.5 boundary. Neither vigorous or nonvigorous exercise was found to be superior in any group or subgroup. CONCLUSIONS: Among individuals diagnosed with phenotypic and/or genotypic LQTS who were risk assessed and treated in experienced centers, LQTS-associated cardiac event rates were low and similar between those exercising vigorously and those not exercising vigorously. Consistent with the low event rate, CIs are wide, and noninferiority was not demonstrated. These data further inform shared decision-making discussions between patient and physician about exercise and competitive sports participation. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02549664.
2023 HRS/APHRS/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure
Chung, Mina K. , Lau, Chu‐Pak, Forno, Alexander Romeno Janner Dal, Arora, Vanita , Birgersdotter‐Green, Ulrika , Cha, Yong‐Mei , Chung, Eugene H. , Cronin, Edmond M. , Curtis, Anne B. , Cygankiewicz, Iwona , Dandamudi, Gopi, Dubin, Anne M. , Ensch, Douglas P., Glotzer, Taya V. , Gold, Michael R. , Goldberger, Zachary D. , Gutiérrez, Alejandra , Guzmán, Juan C. , Indik, Julia H. , Karpawich, Peter P. , Khaykin, Yaariv , Kiehl, Erich L., Kutyifa, Valentina , Müllens, Wilfried , Parkash, Ratika , Patete, Manuel , Pathak, Rajeev K. , Perona, Carlos, Rickard, John , Schoenfeld, Mark H., Seow, Swee‐Chong , Shen, Win‐Kuang , Slotwiner, David J. , Sridhar, Arun Raghav Mahankali , Srivatsa, Uma N. , Stecker, Eric C. , Tanawuttiwat, Tanyanan , Tapias, Carlos A., Upadhyay, Gaurav A. , Vernooy, Kevin , Worsnick, Sarah Ann, Zaręba, Wojciech , Zeitler, Emily P. , Reviewers, Document, López-Cabanillas, Néstor , Ellenbogen, Kenneth A. , Hua, Wei , Ikeda, Takanori , Mackall, Judith A. , Mela, Theofanie , Racenet, Laurel Kay, Mason, Pamela K, Moore, Jeremy P. , Dubin, Anne M , Zareba, Wojciech , Pathak, Rajeev K , Ellenbogen, Kenneth A , Patton, Kristen K. , Forno, Alexander Dal , Al‐Khatib, Sana M. , Ensch, Douglas P., Gopinathannair, Rakesh , Gorodeski, Eiran Z. , Huang, Weijian , Imrey, Peter B. , Karim, Saima , Kron, Jordana , Link, Mark S. , Marine, Joseph Edward , Park, Seung‐Jung , Shoda, Morio , Singh, Jagmeet P , Tang, W.H. Wilson , Tracy, Cynthia M. , Varma, Niraj , Vijayaraman, Pugazhendhi , Reviewers, Document, Mason, Pamela Kay , McLeod, Christopher J.

Journal of Arrhythmia | May 20, 2023 | Volume: 39 | Issue: 5 | Pages: 681-756

10.1002/joa3.12872 Get It

AbstractCardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing‐induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre‐procedure evaluation and preparation, implant procedure management, follow‐up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.
Vigorous Exercise in Patients With Hypertrophic Cardiomyopathy
Lampert, Rachel , Ackerman, Michael J. , Marino, Bradley S. , Burg, Matthew M. , Ainsworth, Barbara E. , Tome, Maite , Abraham, Roselle, Balaji, Seshadri , Barth, Cheryl , Berul, Charles I. , Bos, Martijn, Cannom, David S. , Choudhury, Lubna , Concannon, Maryann, Cooper, Robert , Czosek, Richard J. , Dubin, Anne M. , Dziura, James, Eidem, Benjamin W., Etheridge, Susan P. , Geske, Jeffrey B. , Gray, Belinda , Lal, Ashwin K. , Ommen, Steven R., Saarel, Elizabeth V. , Simone, Laura, Tomaselli, Gordon F., Ware, James S. , Day, Sharlene M. , Abrahms, Dominic Jr, Ashley, Euan A. , Aziz, Peter F. , Batra, Anjan S. , Ferhaan, Ahmad, Gollob, Michael J., Kanter, Ronald J. , Li, Walter, Masri, Ahmad , Murphy, Ann Mooney, Popjes, Eric , Rao, Roopa S, Rosenthal, David N. , Semsarian, Chris, Shah, Maully J. , Tardif, Jill, Towbin, Jeffrey A. , Turer, Aslan T., Bos, J. Martijn , Eidem, Benjamin, Bos, Johan M , Dubin, Anne M , Ware, James S , Geske, Jeffrey B , Tome Esteban, Maria Teresa , Gray, Belinda , Salberg, Lisa , Ho, Carolyn Y. , Dziura, James, Emery, Michael S. , Estes, N.A. Mark , Hall, Kevin D. , Harmon, Kimberly G. , James, Cynthia A. , Law, Ian H. , Li, Fangyong , Link, Mark S. , McKenna, William J. , Molossi, Silvana M , Olshansky, Brian , Saberi, Sara , Zipes, Douglas P. , Cerrone, Marina , Colan, Steven D. , Erickson, Christopher, Ferhaan, Ahmad, Johnsrude, Christopher L. , Kannankeril, Prince J. , Murphy, Ann, Nandi, Deipanjan , Pérez, Marco , Perry, James C. , Rao, Roopa, Sanatani, Shubhayan , Skinner, Jonathan R. , Webster, Gregory , Wever‐Pinzon, Omar , Wong, Timothy C.

JAMA Cardiology | May 17, 2023 | Volume: 8 | Issue: 6 | Pages: 595

10.1001/jamacardio.2023.1042 Get It

Importance Whether vigorous intensity exercise is associated with an increase in risk of ventricular arrhythmias in individuals with hypertrophic cardiomyopathy (HCM) is unknown. Objective To determine whether engagement in vigorous exercise is associated with increased risk for ventricular arrhythmias and/or mortality in individuals with HCM. The a priori hypothesis was that participants engaging in vigorous activity were not more likely to have an arrhythmic event or die than those who reported nonvigorous activity. Design, Setting, and Participants This was an investigator-initiated, prospective cohort study. Participants were enrolled from May 18, 2015, to April 25, 2019, with completion in February 28, 2022. Participants were categorized according to self-reported levels of physical activity: sedentary, moderate, or vigorous-intensity exercise. This was a multicenter, observational registry with recruitment at 42 high-volume HCM centers in the US and internationally; patients could also self-enroll through the central site. Individuals aged 8 to 60 years diagnosed with HCM or genotype positive without left ventricular hypertrophy (phenotype negative) without conditions precluding exercise were enrolled. Exposures Amount and intensity of physical activity. Main Outcomes and Measures The primary prespecified composite end point included death, resuscitated sudden cardiac arrest, arrhythmic syncope, and appropriate shock from an implantable cardioverter defibrillator. All outcome events were adjudicated by an events committee blinded to the patient’s exercise category. Results Among the 1660 total participants (mean [SD] age, 39 [15] years; 996 male [60%]), 252 (15%) were classified as sedentary, and 709 (43%) participated in moderate exercise. Among the 699 individuals (42%) who participated in vigorous-intensity exercise, 259 (37%) participated competitively. A total of 77 individuals (4.6%) reached the composite end point. These individuals included 44 (4.6%) of those classified as nonvigorous and 33 (4.7%) of those classified as vigorous, with corresponding rates of 15.3 and 15.9 per 1000 person-years, respectively. In multivariate Cox regression analysis of the primary composite end point, individuals engaging in vigorous exercise did not experience a higher rate of events compared with the nonvigorous group with an adjusted hazard ratio of 1.01. The upper 95% 1-sided confidence level was 1.48, which was below the prespecified boundary of 1.5 for noninferiority. Conclusions and Relevance Results of this cohort study suggest that among individuals with HCM or those who are genotype positive/phenotype negative and are treated in experienced centers, those exercising vigorously did not experience a higher rate of death or life-threatening arrhythmias than those exercising moderately or those who were sedentary. These data may inform discussion between the patient and their expert clinician around exercise participation.
Cardiac Resynchronization Therapy for Adult Patients With a Failing Systemic Right Ventricle: A Multicenter Study
Kharbanda, Rohit K. , Moore, Jeremy P. , Lloyd, Michael S. , Galotti, Robert, Bogers, Ad J.J.C. , Taverne, Yannick J.H.J. , Madhavan, Malini , McLeod, Christopher J. , Dubin, Anne M. , Mah, Douglas Y. , Chang, Philip M. , Kamp, Anna , Nielsen, Jens Cosedis , Aydın, Alper , Tanel, Ronn E. , Shah, Maully J. , Pilcher, Thomas , Evertz, Reinder , Tan, Reina Bianca , Czosek, Richard J. , Shivkumar, Kalyanam , Groot, Natasja M.S. de , Nielsen, Jens C , Khairy, Paul , Tan, Reina B , Czosek, Richard J , Shivkumar, Kalyanam , de Groot, Natasja M S , Dubin, Anne M , McLeod, Christopher J , Pilcher, Thomas A.

Journal of the American Heart Association | November 8, 2022 | Volume: 11 | Issue: 22 | Pages: No page available

10.1161/jaha.121.025121 Get It

Background The objective of this international multicenter study was to investigate both early and late outcomes of cardiac resynchronization therapy (CRT) in patients with a systemic right ventricle (SRV) and to identify predictors for congestive heart failure readmissions and mortality. Methods and Results This retrospective international multicenter study included 13 centers. The study population comprised 80 adult patients with SRV (48.9% women) with a mean age of 45±14 (range, 18–77) years at initiation of CRT. Median follow‐up time was 4.1 (25th–75th percentile, 1.3–8.3) years. Underlying congenital heart disease consisted of congenitally corrected transposition of the great arteries and dextro‐transposition of the great arteries in 63 (78.8%) and 17 (21.3%) patients, respectively. CRT resulted in significant improvement in functional class (before CRT: III, 25th–75th percentile, II–III; after CRT: II, 25th–75th percentile, II–III; P =0.005) and QRS duration (before CRT: 176±27; after CRT: 150±24 milliseconds; P =0.003) in patients with pre‐CRT ventricular pacing who underwent an upgrade to a CRT device (n=49). These improvements persisted during long‐term follow‐up with a marginal but significant increase in SRV function (before CRT; 30%, 25th–75th percentile, 25–35; after CRT: 31%, 25th–75th percentile, 21–38; P =0.049). In contrast, no beneficial change in the above‐mentioned variables was observed in patients who underwent de novo CRT (n=31). A quarter of all patients were readmitted for heart failure during follow‐up, and mortality at latest follow‐up was 21.3%. Conclusions This international experience with CRT in patients with an SRV demonstrated that CRT in selected patients with SRV dysfunction and pacing‐induced dyssynchrony yielded consistent improvement in QRS duration and New York Heart Association functional status, with a marginal increase in SRV function.
Pediatric Electrophysiology Device Needs: A Survey from the Pediatric and Congenital Electrophysiology Society Taskforce on Pediatric‐Specific Devices
Dubin, Anne M. , Bar‐Cohen, Yaniv , Berul, Charles I. , Cannon, Bryan C. , Saarel, Elizabeth V. , Shah, Maully J. , Triedman, John K. , Saarel, Elizabeth V , Dubin, Anne M

Journal of the American Heart Association | November 3, 2022 | Volume: 11 | Issue: 22 | Pages: No page available

10.1161/jaha.122.026904 Get It

Background There are few US Food and Drug Administration (FDA)–approved devices specifically aimed at the pediatric patient with arrhythmia. This has led to a high off‐label utilization of devices in this vulnerable population. The Pediatric and Congenital Electrophysiology Society (PACES), the international organization representing pediatric and congenital heart disease arrhythmia specialists, developed a task force to comprehensively address device development issues relevant to pediatric patients with congenital arrhythmia. Methods and Results As a first step, the taskforce developed a 26‐question survey for the pediatric arrhythmia community to assess providers’ understanding of the FDA approval process, specifically in regard to pediatric labeling. There were 92/211 respondents (44%) with a >90% completion rate. The vast majority of respondents believed there was a paucity of devices available for children (96%). More than 60% of respondents stated that they did not understand the FDA regulatory process and were not aware of whether the devices they used were labeled for pediatric use. Conclusions Pediatric electrophysiologists are keenly aware of the deficit of available pediatric devices for their patients. The majority do not understand the FDA approval process and could benefit from additional educational resources regarding this. A collaborative forum including PACES, FDA, patients and their families, and Industry would be an important next step in clarifying opportunities and priorities to serve this vulnerable population.
Familial Recurrence Patterns in Congenitally Corrected Transposition of the Great Arteries: An International Study
Tortigue, Marine , Nield, Lynne E. , Karakachoff, Matilde , McLeod, Christopher J. , Belli, Emré , Babu‐Narayan, Sonya V. , Prigent, Solène , Conway, Miriam, Elder, Robert W. , Ladouceur, Magalie , Kowalik, Ewa , Kalfa, David , Mussa, Shafi, Hiippala, Anita , Temple, Joel , Abadir, Sylvia , Gloan, Laurianne Le , Lachaud, Matthias , Sanatani, Shubhayan , Thambo, Jean‐Benoît , Gronier, Céline, Charbonneau, Anne, Koutbi, Linda , Houeijeh, Ali , Combes, Nicolas , Duthoit, Guillaume, Hiel, Bérengère, Erickson, Christopher C. , Bonnet, Caroline , Hare, George F. Van , Dina, Christian , Fournier, Emmanuelle , Bloa, Mathieu Le , Pass, Robert H. , Liberman, Leonardo , Happonen, Juha-Matti, Perry, James C. , Romefort, Bénédicte, Benbrik, Nadir , Hauet, Quentin , Fraisse, Alain , Dubin, Anne M. , Ho, Siew Yen , Redon, Richard , Bacha, Emile , Elder, Robert W , Ladouceur, Magalie , Khairy, Paul , Kowalik, Ewa , Barron, David J , Sanatani, Shubhayan , Amedro, Pascal , Vaksmann, Guy , Ovaert, Caroline , Houeijeh, Ali , Combes, Nicolas , Maury, Philippe , Erickson, Christopher C , Van Hare, George F , Dina, Christian , Fournier, Emmanuelle , Le Bloa, Mathieu , Perry, James C , Benbrik, Nadir , Abrams, Dominic J , Dubin, Anne M , Ho, Siew Yen , Redon, Richard , Baruteau, Alban-Elouen , McLeod, Christopher J , Karakachoff, Matilde , Nield, Lynne E , Babu-Narayan, Sonya V , Belli, Emre , Boët, Angèle , Charbonneau, Anne, Maury, Philippe , Bonnet, Caroline, Karsenty, Clément , Gatzoulis, Michael Α. , Abrams, Dominic J. , Schott, Jean‐Jacques , Baruteau, Alban‐Elouen

Circulation: Genomic and Precision Medicine | May 12, 2022 | Volume: 15 | Issue: 3 | Pages: No page available

10.1161/circgen.121.003464 Get It

Background: Congenitally corrected transposition of the great arteries (ccTGA) is a rare disease of unknown cause. We aimed to better understand familial recurrence patterns. Methods: An international, multicentre, retrospective cohort study was conducted in 29 tertiary hospitals in 6 countries between 1990 and 2018, entailing investigation of 1043 unrelated ccTGA probands. Results: Laterality defects and atrioventricular block at diagnosis were observed in 29.9% and 9.3%, respectively. ccTGA was associated with primary ciliary dyskinesia in 11 patients. Parental consanguinity was noted in 3.4% cases. A congenital heart defect was diagnosed in 81 relatives from 69 families, 58% of them being first-degree relatives, including 28 siblings. The most prevalent defects in relatives were dextro-transposition of the great arteries (28.4%), laterality defects (13.6%), and ccTGA (11.1%); 36 new familial clusters were described, including 8 pedigrees with concordant familial aggregation of ccTGA, 19 pedigrees with familial co-segregation of ccTGA and dextro-transposition of the great arteries, and 9 familial co-segregation of ccTGA and laterality defects. In one family co-segregation of ccTGA, dextro-transposition of the great arteries and heterotaxy syndrome in 3 distinct relatives was found. In another family, twins both displayed ccTGA and primary ciliary dyskinesia. Conclusions: ccTGA is not always a sporadic congenital heart defect. Familial clusters as well as evidence of an association between ccTGA, dextro-transposition of the great arteries, laterality defects and in some cases primary ciliary dyskinesia, strongly suggest a common pathogenetic pathway involving laterality genes in the pathophysiology of ccTGA.
Multi-Institutional Study of Implantable Defibrillator Lead Performance in Children and Young Adults
Atallah, Joseph , Erickson, Christopher C. , Cecchin, Frank , Dubin, Anne M. , Law, Ian H. , Cohen, Mitchell I. , Cannon, Bryan C. , Freedenberg, Vicki , Gierdalski, Marcin , Berul, Charles I. , LaPage, Martin J , Chun, Terrence , Atallah, Joseph , Dubin, Anne M , Law, Ian H

Circulation | May 21, 2013 | Volume: 127 | Issue: 24 | Pages: 2393-2402

10.1161/circulationaha.112.001120 Get It

Background— Implantable cardioverter-defibrillator (ICD) therapy in children and congenital heart disease patients is hampered by poor long-term lead survival. Lead extraction is technically difficult and carries substantial morbidity. We sought to determine the outcomes of ICD leads in pediatric and congenital heart disease patients. Methods and Results— The Pediatric Lead Extractability and Survival Evaluation (PLEASE) is a 24-center international registry. Pediatric and congenital heart disease patients with ICD lead implantations from 2005 to 2010 were eligible. Study subjects comprised 878 ICD patients (44% congenital heart disease). Mean±SD age at implantation was 18.6±9.8 years. Of the 965 total leads, 54% were thin (≤7F), of which 57% were Fidelis, and 23% were coated with expanded polytetrafluoroethylene. There were 139 ICD lead failures (14%) in 132 patients (15%) at a mean lead age of 2.0±1.4 years, causing shocks in 53 patients (40%). Independent predictors of lead failure included younger implantation age and Fidelis leads. Actuarial analysis showed an incremental risk of lead failure with younger age at implantation: <8 years compared with >18 years ( P =0.015). The actuarial yearly failure rate was 2.3% for non-Fidelis and 9.1% for Fidelis leads. Extraction was performed on 143 leads (80% thin, 7% expanded polytetrafluoroethylene coated), with lead age as the only independent predictor for advanced extraction techniques. There were 6 major extraction complications (4%) but no procedural mortality. Conclusions— This study demonstrates that ICD leads in children and congenital heart disease patients have an age-related suboptimal performance, further compounded by a high failure rate of Fidelis leads. Advanced extraction techniques were common and correlated with older lead age. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00335036.