One-Year Outcomes of the MODULAR ATP Trial: A Novel Leadless Pacemaker in Wireless Communication With a Subcutaneous Implantable Cardioverter Defibrillator
BACKGROUND: MODULAR antitachycardia pacing (ATP), a multicenter, international trial, assesses a modular cardiac rhythm management system: a subcutaneous implantable cardioverter defibrillator in wireless communication with a leadless pacemaker (LP) capable of pace-terminating ventricular tachycardia. METHODS: Enrolees had one or more clinical risk factors for ventricular tachycardia and did not require chronic pacing. Complications included prespecified major LP system- and procedure-related complications, and any complication related to the LP, subcutaneous implantable cardioverter defibrillator, implantation, or study protocol. Survival analysis was performed to identify complication-free rates, therapy delivery, and all-cause mortality. RESULTS: The 297 patients enrolled had an ejection fraction of 35±13%, 43% secondary prevention indications, and 59% with prior ventricular arrhythmias. Of 286 patients undergoing LP implantation (100% success), 251 patients completed 12-month follow-up. Mortality rate was 6%, with none related to the implant procedure. Median follow-up duration was 23.4 months (interquartile range, 17.9–28.1). The LP major complication-free rate was 97.2%, exceeding the performance goal. The overall LP+ subcutaneous implantable cardioverter defibrillator system-related complication-free rate was 88.5%. Appropriate tachyarrhythmia-therapy (ATP+shock) rates were 14.4%, and appropriate shock rates were 8.5%. Inappropriate total tachyarrhythmia therapy was 9.5% of which 8.5% were shocks. ATP was 67.3% successful in terminating ventricular arrhythmia episodes and accelerated ventricular arrhythmias in 10.1% of episodes. Overall therapy burden (ATP+shock) was 96/100 patient-years, of which 44/100 patient-years was for shock delivery. CONCLUSIONS: One-year outcomes of the first modular pacing-defibrillator system reveal low system and LP complication rates and good ATP efficacy rates, suggesting that the modular cardiac rhythm management is a viable alternative to single-chamber implantable cardioverter defibrillators using low-energy pacing capability without the need for transvenous leads. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/ ; Unique identifier: NCT04798768.
A Modular Communicative Leadless Pacing–Defibrillator System
Background : Modulation of the cardiac autonomic nervous system (ANS) is a promising adjuvant therapy in the treatment of atrial fibrillation (AF). In pre-clinical models, pulsed field (PF) energy has the advantage of selectively ablating the epicardial ganglionated plexi (GP) that govern the ANS. Objective: This study aims to demonstrate the feasibility and safety of epicardial ablation of the GPs with PF during cardiac surgery with a primary efficacy outcome of prolongation of the atrial effective refractory period (AERP). Methods : In a single-arm, prospective analysis, patients with or without a history of AF underwent epicardial GP ablation with PF during coronary artery bypass grafting (CABG). AERP was determined immediately pre- and post- GP ablation to assess cardiac ANS function. Holter monitors were performed to determine rhythm status and Heart Rate Variability (HRV) at baseline and at 1 month post-procedure. Conclusions : This study demonstrates the safety and feasibility of epicardial ablation of the GP using PF to modulate the ANS during cardiac surgery. Large, randomized analyses are necessary to determine whether epicardial PF ablation can offer a meaningful impact on the cardiac ANS and reduce AF. Results : Of 24 patients, 23 (96%) received the full ablation protocol. No device-related adverse effects were noted. GP ablation resulted in a 20.7% ± 19.9% extension in AERP (P < 0.001). Post-operative AF was observed in 7 (29%) patients. Holter monitoring demonstrated an increase in mean heart rate (74.0±8.7 vs 80.6±12.3, P=0.01). There were no significant changes in HRV. There were no study-related complications.
Percutaneous Left Atrial Appendage Closure vs Warfarin for Atrial Fibrillation
Background— The multicenter PROTECT AF study (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) was conducted to determine whether percutaneous left atrial appendage closure with a filter device (Watchman) was noninferior to warfarin for stroke prevention in atrial fibrillation. Methods and Results— Patients (n=707) with nonvalvular atrial fibrillation and at least 1 risk factor (age >75 years, hypertension, heart failure, diabetes, or prior stroke/transient ischemic attack) were randomized to either the Watchman device (n=463) or continued warfarin (n=244) in a 2:1 ratio. After device implantation, warfarin was continued for ≈45 days, followed by clopidogrel for 4.5 months and lifelong aspirin. Study discontinuation rates were 15.3% (71/463) and 22.5% (55/244) for the Watchman and warfarin groups, respectively. The time in therapeutic range for the warfarin group was 66%. The composite primary efficacy end point included stroke, systemic embolism, and cardiovascular death, and the primary analysis was by intention to treat. After 1588 patient-years of follow-up (mean 2.3±1.1 years), the primary efficacy event rates were 3.0% and 4.3% (percent per 100 patient-years) in the Watchman and warfarin groups, respectively (relative risk, 0.71; 95% confidence interval, 0.44%–1.30% per year), which met the criteria for noninferiority (probability of noninferiority >0.999). There were more primary safety events in the Watchman group (5.5% per year; 95% confidence interval, 4.2%–7.1% per year) than in the control group (3.6% per year; 95% confidence interval, 2.2%–5.3% per year; relative risk, 1.53; 95% confidence interval, 0.95–2.70). Conclusions— The “local” strategy of left atrial appendage closure is noninferior to “systemic” anticoagulation with warfarin. PROTECT AF has, for the first time, implicated the left atrial appendage in the pathogenesis of stroke in atrial fibrillation. Clinical Trial Registration:— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00129545.
Safety of Percutaneous Left Atrial Appendage Closure
Background— The Watchman Left Atrial Appendage System for Embolic Protection in Patients With AF (PROTECT AF) randomized trial compared left atrial appendage closure against warfarin in atrial fibrillation (AF) patients with CHADS 2 ≥1. Although the study met the primary efficacy end point of being noninferior to warfarin therapy for the prevention of stroke/systemic embolism/cardiovascular death, there was a significantly higher risk of complications, predominantly pericardial effusion and procedural stroke related to air embolism. Here, we report the influence of experience on the safety of percutaneous left atrial appendage closure. Methods and Results— The study cohort for this analysis included patients in the PROTECT AF trial who underwent attempted device left atrial appendage closure (n=542 patients) and those from a subsequent nonrandomized registry of patients undergoing Watchman implantation (Continued Access Protocol [CAP] Registry; n=460 patients). The safety end point included bleeding- and procedure-related events (pericardial effusion, stroke, device embolization). There was a significant decline in the rate of procedure- or device-related safety events within 7 days of the procedure across the 2 studies, with 7.7% and 3.7% of patients, respectively, experiencing events ( P =0.007), and between the first and second halves of PROTECT AF and CAP, with 10.0%, 5.5%, and 3.7% of patients, respectively, experiencing events ( P =0.006). The rate of serious pericardial effusion within 7 days of implantation, which had made up >50% of the safety events in PROTECT AF, was lower in the CAP Registry (5.0% versus 2.2%, respectively; P =0.019). There was a similar experience-related improvement in procedure-related stroke (0.9% versus 0%, respectively; P =0.039). Finally, the functional impact of these safety events, as defined by significant disability or death, was statistically superior in the Watchman group compared with the warfarin group in PROTECT AF. This remained true whether significance was defined as a change in the modified Rankin score of ≥1, ≥2, or ≥3 (1.8 versus 4.3 events per 100 patient-years; relative risk, 0.43; 95% confidence interval, 0.24 to 0.82; 1.5 versus 3.7 events per 100 patient-years; relative risk, 0.41; 95% confidence interval, 0.22 to 0.82; and 1.4 versus 3.3 events per 100 patient-years; relative risk, 0.43; 95% confidence interval, 0.22 to 0.88, respectively). Conclusion— As with all interventional procedures, there is a significant improvement in the safety of Watchman left atrial appendage closure with increased operator experience. Clinical Trial Registration— URL: http://clinicaltrials.gov . Unique identifier: NCT00129545.