Back to Authors

Gras, Daniel

https://orcid.org/0000-0002-7980-6036

Mayo Clinic

Hôpital privé du Confluent

Citations 2

One-Year Outcomes of the MODULAR ATP Trial: A Novel Leadless Pacemaker in Wireless Communication With a Subcutaneous Implantable Cardioverter Defibrillator
Lloyd, Michael S. , Roberts, Paul R. , Doshi, Rahul N. , Wright, David J. , Boersma, Lucas V.A. , Friedman, Paul A. , Neužil, Petr , Blomström‐Lundqvist, Carina , Bongiorni, M. G. , Burke, Martin C. , Gras, Daniel , Kutalek, Steven , Marijon, Éloi , Amin, Anish K. , Aasbo, Johan D. , West, Julie, Matznick, Elizabeth , Speakman, Benjamin, Bachman, Tara N. , Reddy, Vivek Y , Roberts, Paul , Doshi, Rahul N , Wright, David L , Boersma, Lucas , Friedman, Paul A , Neuzil, Petr , Blomström-Lundqvist, Carina , Bongiorni, Maria Grazia , Burke, Martin C , Gras, Daniel , Kutalek, Steven P , Marijon, Eloi , Tolosana, Jose María , Amin, Anish K , Epstein, Laurence M , Aasbo, Johan D , Callahan, Thomas D , Brisben, Amy J , Matznick, Elizabeth , Bachman, Tara N , Mont, Lluís , Knops, Reinoud Elwin , Reddy, Vivek Y. , Epstein, Laurence M.

Circulation: Arrhythmia and Electrophysiology | November 13, 2025 | Volume: 19 | Issue: 1 | Pages: No page available

10.1161/circep.125.014395 Get It

BACKGROUND: MODULAR antitachycardia pacing (ATP), a multicenter, international trial, assesses a modular cardiac rhythm management system: a subcutaneous implantable cardioverter defibrillator in wireless communication with a leadless pacemaker (LP) capable of pace-terminating ventricular tachycardia. METHODS: Enrolees had one or more clinical risk factors for ventricular tachycardia and did not require chronic pacing. Complications included prespecified major LP system- and procedure-related complications, and any complication related to the LP, subcutaneous implantable cardioverter defibrillator, implantation, or study protocol. Survival analysis was performed to identify complication-free rates, therapy delivery, and all-cause mortality. RESULTS: The 297 patients enrolled had an ejection fraction of 35±13%, 43% secondary prevention indications, and 59% with prior ventricular arrhythmias. Of 286 patients undergoing LP implantation (100% success), 251 patients completed 12-month follow-up. Mortality rate was 6%, with none related to the implant procedure. Median follow-up duration was 23.4 months (interquartile range, 17.9–28.1). The LP major complication-free rate was 97.2%, exceeding the performance goal. The overall LP+ subcutaneous implantable cardioverter defibrillator system-related complication-free rate was 88.5%. Appropriate tachyarrhythmia-therapy (ATP+shock) rates were 14.4%, and appropriate shock rates were 8.5%. Inappropriate total tachyarrhythmia therapy was 9.5% of which 8.5% were shocks. ATP was 67.3% successful in terminating ventricular arrhythmia episodes and accelerated ventricular arrhythmias in 10.1% of episodes. Overall therapy burden (ATP+shock) was 96/100 patient-years, of which 44/100 patient-years was for shock delivery. CONCLUSIONS: One-year outcomes of the first modular pacing-defibrillator system reveal low system and LP complication rates and good ATP efficacy rates, suggesting that the modular cardiac rhythm management is a viable alternative to single-chamber implantable cardioverter defibrillators using low-energy pacing capability without the need for transvenous leads. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/ ; Unique identifier: NCT04798768.