Back to Authors

Miller, Marc A

0000-0001-7512-4727

Mayo Clinic

Icahn School of Medicine at Mount Sinai, Mount Sinai Hospital, New York, New York, USA.

Citations 2

Process mapping strategies to prevent subcutaneous implantable cardioverter‐defibrillator infections
Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , McClernon, Timothy R., Knight, Bradley P. , El-Chami, Mikhael F , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , Weiss, Raul , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Hansen, Linda K. , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | June 4, 2022 | Volume: 33 | Issue: 7 | Pages: 1628-1635

10.1111/jce.15566 Get It

AbstractBackgroundInfection remains a major complication of cardiac implantable electronic devices and can lead to significant morbidity and mortality. Implantable devices that avoid transvenous leads, such as the subcutaneous implantable cardioverter‐defibrillator (S‐ICD), can reduce the risk of serious infection‐related complications, such as bloodstream infection and infective endocarditis. While the 2017 AHA/ACC/HRS guidelines include recommendations for S‐ICD use for patients at high risk of infection, currently, there are no clinical trial data that address best practices for the prevention of S‐ICD infections. Therefore, an expert panel was convened to develop a consensus on these topics.MethodsAn expert process mapping methodology was used to achieve consensus on the appropriate steps to minimize or prevent S‐ICD infections. Two face‐to‐face meetings of high‐volume S‐ICD implanters and an infectious diseases specialist, with expertise in cardiovascular implantable electronic device infections, were conducted to develop consensus on useful strategies pre‐, peri‐, and postimplant to reduce S‐ICD infection risk.ResultsExpert panel consensus on recommended steps for patient preparation, S‐ICD implantation, and postoperative management was developed to provide guidance in individual patient management.ConclusionAchieving expert panel consensus by process mapping methodology for S‐ICD infection prevention was attainable, and the results should be helpful to clinicians in adopting interventions to minimize risks of S‐ICD infection.
Device‐related infection associated with increased mortality risk in de novo transvenous implantable cardioverter‐defibrillator medicare patients
Liu, Yiyan , Griffiths, Robert I. , Knight, Bradley P. , Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , Jacobsen, Caroline M., El-Chami, Mikhael F , Weiss, Raul , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | January 23, 2022 | Volume: 33 | Issue: 4 | Pages: 725-730

10.1111/jce.15385 Get It

AbstractIntroductionTransvenous implantable cardioverter‐defibrillators (TV‐ICD) infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to assess mortality risk associated with TV‐ICD infection in a large Medicare population with de novo TV‐ICD implants.MethodsA survival analysis was conducted using 100% fee‐for‐service Medicare facility‐level claims data to identify patients who underwent de novo TV‐ICD implantation between 7/2016 and 1/2018. TV‐ICD infection within 2 years of implantation was identified using International Classification of Disease, 10th Edition and current procedural terminology codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time‐dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias.ResultsAmong 26,742 Medicare patients with de novo TV‐ICD, 518 (1.9%) had a device‐related infection. The overall number of decedents was 4721 (17.7%) over 2 years, with 4555 (17%) in the noninfection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV‐ICD infection was associated with an increase of 2.4 (95% CI: 2.08–2.85) times in the mortality hazard ratio.ConclusionThe rate of TV‐ICD infection and associated mortality in a large, real‐world Medicare population is noteworthy. The positive association between device‐related infection and risk of mortality further highlights the need to reduce infections